Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(2)2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38257664

RESUMO

In overcoming the worldwide problem of overweight and obesity, automatic dietary monitoring (ADM) is introduced as support in dieting practises. ADM aims to automatically, continuously, and objectively measure dimensions of food intake in a free-living environment. This could simplify the food registration process, thereby overcoming frequent memory, underestimation, and overestimation problems. In this study, an eating event detection sensor system was developed comprising a smartwatch worn on the wrist containing an accelerometer and gyroscope for eating gesture detection, a piezoelectric sensor worn on the jaw for chewing detection, and a respiratory inductance plethysmographic sensor consisting of two belts worn around the chest and abdomen for food swallowing detection. These sensors were combined to determine to what extent a combination of sensors focusing on different steps of the dietary cycle can improve eating event classification results. Six subjects participated in an experiment in a controlled setting consisting of both eating and non-eating events. Features were computed for each sensing measure to train a support vector machine model. This resulted in F1-scores of 0.82 for eating gestures, 0.94 for chewing food, and 0.58 for swallowing food.


Assuntos
Manipulação de Alimentos , Gestos , Humanos , Mastigação , Obesidade , Acelerometria
2.
Sensors (Basel) ; 24(7)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38610374

RESUMO

After an ACL injury, rehabilitation consists of multiple phases, and progress between these phases is guided by subjective visual assessments of activities such as running, hopping, jump landing, etc. Estimation of objective kinetic measures like knee joint moments and GRF during assessment can help physiotherapists gain insights on knee loading and tailor rehabilitation protocols. Conventional methods deployed to estimate kinetics require complex, expensive systems and are limited to laboratory settings. Alternatively, multiple algorithms have been proposed in the literature to estimate kinetics from kinematics measured using only IMUs. However, the knowledge about their accuracy and generalizability for patient populations is still limited. Therefore, this article aims to identify the available algorithms for the estimation of kinetic parameters using kinematics measured only from IMUs and to evaluate their applicability in ACL rehabilitation through a comprehensive systematic review. The papers identified through the search were categorized based on the modelling techniques and kinetic parameters of interest, and subsequently compared based on the accuracies achieved and applicability for ACL patients during rehabilitation. IMUs have exhibited potential in estimating kinetic parameters with good accuracy, particularly for sagittal movements in healthy cohorts. However, several shortcomings were identified and future directions for improvement have been proposed, including extension of proposed algorithms to accommodate multiplanar movements and validation of the proposed techniques in diverse patient populations and in particular the ACL population.


Assuntos
Lesões do Ligamento Cruzado Anterior , Tomada de Decisão Clínica , Humanos , Algoritmos , Nível de Saúde , Cinética
3.
Sensors (Basel) ; 23(13)2023 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-37447718

RESUMO

This study aims to evaluate the feasibility and explore the efficacy of the Arm Activity Tracker (AAT). The AAT is a device based on wrist-worn accelerometers that provides visual and tactile feedback to stimulate daily life upper extremity (UE) activity in stroke patients. METHODS: A randomised, crossover within-subject study was conducted in sub-acute stroke patients admitted to a rehabilitation centre. Feasibility encompassed (1) adherence: the dropout rate and the number of participants with insufficient AAT data collection; (2) acceptance: the technology acceptance model (range: 7-112) and (3) usability: the system usability scale (range: 0-100). A two-way ANOVA was used to estimate the difference between the baseline, intervention and control conditions for (1) paretic UE activity and (2) UE activity ratio. RESULTS: Seventeen stroke patients were included. A 29% dropout rate was observed, and two participants had insufficient data collection. Participants who adhered to the study reported good acceptance (median (IQR): 94 (77-111)) and usability (median (IQR): 77.5 (75-78.5)-). We found small to medium effect sizes favouring the intervention condition for paretic UE activity (η2G = 0.07, p = 0.04) and ratio (η2G = 0.11, p = 0.22). CONCLUSION: Participants who adhered to the study showed good acceptance and usability of the AAT and increased paretic UE activity. Dropouts should be further evaluated, and a sufficiently powered trial should be performed to analyse efficacy.


Assuntos
Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Estudos de Viabilidade , Retroalimentação , Extremidade Superior , Recuperação de Função Fisiológica
4.
Sensors (Basel) ; 22(8)2022 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-35458993

RESUMO

Physical exercise (PE) is beneficial for both physical and psychological health aspects. However, excessive training can lead to physical fatigue and an increased risk of lower limb injuries. In order to tailor training loads and durations to the needs and capacities of an individual, physical fatigue must be estimated. Different measurement devices and techniques (i.e., ergospirometers, electromyography, and motion capture systems) can be used to identify physical fatigue. The field of biomechanics has succeeded in capturing changes in human movement with optical systems, as well as with accelerometers or inertial measurement units (IMUs), the latter being more user-friendly and adaptable to real-world scenarios due to its wearable nature. There is, however, still a lack of consensus regarding the possibility of using biomechanical parameters measured with accelerometers to identify physical fatigue states in PE. Nowadays, the field of biomechanics is beginning to open towards the possibility of identifying fatigue state using machine learning algorithms. Here, we selected and summarized accelerometer-based articles that either (a) performed analyses of biomechanical parameters that change due to fatigue in the lower limbs or (b) performed fatigue identification based on features including biomechanical parameters. We performed a systematic literature search and analysed 39 articles on running, jumping, walking, stair climbing, and other gym exercises. Peak tibial and sacral acceleration were the most common measured variables and were found to significantly increase with fatigue (respectively, in 6/13 running articles and 2/4 jumping articles). Fatigue classification was performed with an accuracy between 78% and 96% and Pearson's correlation with an RPE (rate of perceived exertion) between r = 0.79 and r = 0.95. We recommend future effort toward the standardization of fatigue protocols and methods across articles in order to generalize fatigue identification results and increase the use of accelerometers to quantify physical fatigue in PE.


Assuntos
Corrida , Acelerometria , Fenômenos Biomecânicos , Exercício Físico , Fadiga , Humanos , Extremidade Inferior
5.
J Neuroeng Rehabil ; 18(1): 37, 2021 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-33596942

RESUMO

BACKGROUND: The foot progression angle is an important measure used to help patients reduce their knee adduction moment. Current measurement systems are either lab-bounded or do not function in all environments (e.g., magnetically distorted). This work proposes a novel approach to estimate foot progression angle using a single foot-worn inertial sensor (accelerometer and gyroscope). METHODS: The approach uses a dynamic step frame that is recalculated for the stance phase of each step to calculate the foot trajectory relative to that frame, to minimize effects of drift and to eliminate the need for a magnetometer. The foot progression angle (FPA) is then calculated as the angle between walking direction and the dynamic step frame. This approach was validated by gait measurements with five subjects walking with three gait types (normal, toe-in and toe-out). RESULTS: The FPA was estimated with a maximum mean error of ~ 2.6° over all gait conditions. Additionally, the proposed inertial approach can significantly differentiate between the three different gait types. CONCLUSION: The proposed approach can effectively estimate differences in FPA without requiring a heading reference (magnetometer). This work enables feedback applications on FPA for patients with gait disorders that function in any environment, i.e. outside of a gait lab or in magnetically distorted environments.


Assuntos
Análise da Marcha/instrumentação , Dispositivos Eletrônicos Vestíveis , Acelerometria/instrumentação , Adulto , Fenômenos Biomecânicos , Pé/fisiopatologia , Humanos , Masculino
6.
J Neuroeng Rehabil ; 18(1): 144, 2021 09 24.
Artigo em Inglês | MEDLINE | ID: mdl-34560898

RESUMO

BACKGROUND: The cause of smoothness deficits as a proxy for quality of movement post stroke is currently unclear. Previous simulation analyses showed that spectral arc length (SPARC) is a valid metric for investigating smoothness during a multi-joint goal-directed reaching task. The goal of this observational study was to investigate how SPARC values change over time, and whether SPARC is longitudinally associated with the recovery from motor impairments reflected by the Fugl-Meyer motor assessment of the upper extremity (FM-UE) in the first 6 months after stroke. METHODS: Forty patients who suffered a first-ever unilateral ischemic stroke (22 males, aged 58.6 ± 12.5 years) with upper extremity paresis underwent kinematic and clinical measurements in weeks 1, 2, 3, 4, 5, 8, 12, and 26 post stroke. Clinical measures included amongst others FM-UE. SPARC was obtained by three-dimensional kinematic measurements using an electromagnetic motion tracking system during a reach-to-grasp movement. Kinematic assessments of 12 healthy, age-matched individuals served as reference. Longitudinal linear mixed model analyses were performed to determine SPARC change over time, compare smoothness in patients with reference values of healthy individuals, and establish the longitudinal association between SPARC and FM-UE scores. RESULTS: SPARC showed a significant positive longitudinal association with FM-UE (B: 31.73, 95%-CI: [27.27 36.20], P < 0.001), which encompassed significant within- and between-subject effects (B: 30.85, 95%-CI: [26.28 35.41], P < 0.001 and B: 50.59, 95%-CI: [29.97 71.21], P < 0.001, respectively). Until 5 weeks post stroke, progress of time contributed significantly to the increase in SPARC and FM-UE scores (P < 0.05), whereafter they levelled off. At group level, smoothness was lower in patients who suffered a stroke compared to healthy subjects at all time points (P < 0.05). CONCLUSIONS: The present findings show that, after stroke, recovery of smoothness in a multi-joint reaching task and recovery from motor impairments are longitudinally associated and follow a similar time course. This suggests that the reduction of smoothness deficits quantified by SPARC is a proper objective reflection of recovery from motor impairment, as reflected by FM-UE, probably driven by a common underlying process of spontaneous neurological recovery early post stroke.


Assuntos
Transtornos Motores , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Masculino , Paresia/etiologia , Recuperação de Função Fisiológica , Acidente Vascular Cerebral/complicações , Extremidade Superior
7.
J Neuroeng Rehabil ; 18(1): 154, 2021 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-34702281

RESUMO

BACKGROUND: Smoothness is commonly used for measuring movement quality of the upper paretic limb during reaching tasks after stroke. Many different smoothness metrics have been used in stroke research, but a 'valid' metric has not been identified. A systematic review and subsequent rigorous analysis of smoothness metrics used in stroke research, in terms of their mathematical definitions and response to simulated perturbations, is needed to conclude whether they are valid for measuring smoothness. Our objective was to provide a recommendation for metrics that reflect smoothness after stroke based on: (1) a systematic review of smoothness metrics for reaching used in stroke research, (2) the mathematical description of the metrics, and (3) the response of metrics to simulated changes associated with smoothness deficits in the reaching profile. METHODS: The systematic review was performed by screening electronic databases using combined keyword groups Stroke, Reaching and Smoothness. Subsequently, each metric identified was assessed with mathematical criteria regarding smoothness: (a) being dimensionless, (b) being reproducible, (c) being based on rate of change of position, and (d) not being a linear transform of other smoothness metrics. The resulting metrics were tested for their response to simulated changes in reaching using models of velocity profiles with varying reaching distances and durations, harmonic disturbances, noise, and sub-movements. Two reaching tasks were simulated; reach-to-point and reach-to-grasp. The metrics that responded as expected in all simulation analyses were considered to be valid. RESULTS: The systematic review identified 32 different smoothness metrics, 17 of which were excluded based on mathematical criteria, and 13 more as they did not respond as expected in all simulation analyses. Eventually, we found that, for reach-to-point and reach-to-grasp movements, only Spectral Arc Length (SPARC) was found to be a valid metric. CONCLUSIONS: Based on this systematic review and simulation analyses, we recommend the use of SPARC as a valid smoothness metric in both reach-to-point and reach-to-grasp tasks of the upper limb after stroke. However, further research is needed to understand the time course of smoothness measured with SPARC for the upper limb early post stroke, preferably in longitudinal studies.


Assuntos
Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Benchmarking , Fenômenos Biomecânicos , Humanos , Movimento , Acidente Vascular Cerebral/complicações , Extremidade Superior
8.
Sensors (Basel) ; 21(10)2021 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-34063478

RESUMO

Physical fatigue is a recurrent problem in running that negatively affects performance and leads to an increased risk of being injured. Identification and management of fatigue helps reducing such negative effects, but is presently commonly based on subjective fatigue measurements. Inertial sensors can record movement data continuously, allowing recording for long durations and extensive amounts of data. Here we aimed to assess if inertial measurement units (IMUs) can be used to distinguish between fatigue levels during an outdoor run with a machine learning classification algorithm trained on IMU-derived biomechanical features, and what is the optimal configuration to do so. Eight runners ran 13 laps of 400 m on an athletic track at a constant speed with 8 IMUs attached to their body (feet, tibias, thighs, pelvis, and sternum). Three segments were extracted from the run: laps 2-4 (no fatigue condition, Rating of Perceived Exertion (RPE) = 6.0 ± 0.0); laps 8-10 (mild fatigue condition, RPE = 11.7 ± 2.0); laps 11-13 (heavy fatigue condition, RPE = 14.2 ± 3.0), run directly after a fatiguing protocol (progressive increase of speed until RPE ≥ 16) that followed lap 10. A random forest classification algorithm was trained with selected features from the 400 m moving average of the IMU-derived accelerations, angular velocities, and joint angles. A leave-one-subject-out cross validation was performed to assess the optimal combination of IMU locations to detect fatigue and selected sensor configurations were considered. The left tibia was the most recurrent sensor location, resulting in accuracies ranging between 0.761 (single left tibia location) and 0.905 (all IMU locations). These findings contribute toward a balanced choice between higher accuracy and lower intrusiveness in the development of IMU-based fatigue detection devices in running.


Assuntos
Corrida , Aceleração , Fenômenos Biomecânicos , , Aprendizado de Máquina
9.
Sensors (Basel) ; 20(14)2020 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-32707635

RESUMO

Relative orientation estimation between the hand and its fingers is important in many applications, such as virtual reality (VR), augmented reality (AR) and rehabilitation. It is still quite a big challenge to do the estimation by only exploiting inertial measurement units (IMUs) because of the integration drift that occurs in most approaches. When the hand is functionally used, there are many instances in which hand and finger tips move together, experiencing almost the same angular velocities, and in some of these cases, almost the same accelerations are measured in different 3D coordinate systems. Therefore, we hypothesize that relative orientations between the hand and the finger tips can be adequately estimated using 3D IMUs during such designated events (DEs) and in between these events. We fused this extra information from the DEs and IMU data with an extended Kalman filter (EKF). Our results show that errors in relative orientation can be smaller than five degrees if DEs are constantly present and the linear and angular movements of the whole hand are adequately rich. When the DEs are partially available in a functional water-drinking task, the orientation error is smaller than 10 degrees.


Assuntos
Algoritmos , Dedos , Mãos , Movimento , Aceleração , Fenômenos Biomecânicos , Humanos
10.
Sensors (Basel) ; 20(21)2020 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-33171858

RESUMO

As an alternative to force plates, an inertial measurement unit (IMU) at the pelvis can offer an ambulatory method for measuring total center of mass (CoM) accelerations and, thereby, the ground reaction forces (GRF) during gait. The challenge here is to estimate the 3D components of the GRF. We employ a calibration procedure and an error state extended Kalman filter based on an earlier work to estimate the instantaneous 3D GRF for different over-ground walking patterns. The GRF were then expressed in a body-centric reference frame, to enable an ambulatory setup not related to a fixed global frame. The results were validated with ForceShoesTM, and the average error in estimating instantaneous shear GRF was 5.2 ± 0.5% of body weight across different variable over-ground walking tasks. The study shows that a single pelvis IMU can measure 3D GRF in a minimal and ambulatory manner during over-ground gait.


Assuntos
Análise da Marcha/métodos , Caminhada , Aceleração , Fenômenos Biomecânicos , Humanos , Pelve
11.
Sensors (Basel) ; 19(17)2019 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-31461958

RESUMO

Full-body motion capture typically requires sensors/markers to be placed on each rigid body segment, which results in long setup times and is obtrusive. The number of sensors/markers can be reduced using deep learning or offline methods. However, this requires large training datasets and/or sufficient computational resources. Therefore, we investigate the following research question: "What is the performance of a shallow approach, compared to a deep learning one, for estimating time coherent full-body poses using only five inertial sensors?". We propose to incorporate past/future inertial sensor information into a stacked input vector, which is fed to a shallow neural network for estimating full-body poses. Shallow and deep learning approaches are compared using the same input vector configurations. Additionally, the inclusion of acceleration input is evaluated. The results show that a shallow learning approach can estimate full-body poses with a similar accuracy (~6 cm) to that of a deep learning approach (~7 cm). However, the jerk errors are smaller using the deep learning approach, which can be the effect of explicit recurrent modelling. Furthermore, it is shown that the delay using a shallow learning approach (72 ms) is smaller than that of a deep learning approach (117 ms).


Assuntos
Técnicas Biossensoriais , Marcha/fisiologia , Monitorização Fisiológica/métodos , Movimento/fisiologia , Aceleração , Algoritmos , Corpo Humano , Humanos , Aprendizado de Máquina , Redes Neurais de Computação , Postura/fisiologia
12.
J Neuroeng Rehabil ; 13(1): 48, 2016 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-27198134

RESUMO

BACKGROUND: For optimal guidance of walking rehabilitation therapy of stroke patients in an in-home setting, a small and easy to use wearable system is needed. In this paper we present a new shoe-integrated system that quantifies walking balance during activities of daily living and is not restricted to a lab environment. Quantitative parameters were related to clinically assessed level of balance in order to assess the additional information they provide. METHODS: Data of 13 participants who suffered a stroke were recorded while walking 10 meter trials and wearing special instrumented shoes. The data from 3D force and torque sensors, 3D inertial sensors and ultrasound transducers were fused to estimate 3D (relative) position, velocity, orientation and ground reaction force of each foot. From these estimates, center of mass and base of support were derived together with a dynamic stability margin, which is the (velocity) extrapolated center of mass with respect to the front-line of the base of support in walking direction. Additionally, for each participant step lengths and stance times for both sides as well as asymmetries of these parameters were derived. RESULTS: Using the proposed shoe-integrated system, a complete reconstruction of the kinematics and kinetics of both feet during walking can be made. Dynamic stability margin and step length symmetry were not significantly correlated with Berg Balance Scale (BBS) score, but participants with a BBS score below 45 showed a small-positive dynamic stability margin and more asymmetrical step lengths. More affected participants, having a lower BBS score, have a lower walking speed, make smaller steps, longer stance times and have more asymmetrical stance times. CONCLUSIONS: The proposed shoe-integrated system and data analysis methods can be used to quantify daily-life walking performance and walking balance, in an ambulatory setting without the use of a lab restricted system. The presented system provides additional insight about the balance mechanism, via parameters describing walking patterns of an individual subject. This information can be used for patient specific and objective evaluation of walking balance and a better guidance of therapies during the rehabilitation. TRIAL REGISTRATION: The study protocol is a subset of a larger protocol and registered in the Netherlands Trial Registry, number NTR3636 .


Assuntos
Equilíbrio Postural , Sapatos , Acidente Vascular Cerebral/fisiopatologia , Caminhada , Atividades Cotidianas , Adulto , Idoso , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/diagnóstico por imagem , Torque , Ultrassom
13.
Front Sports Act Living ; 6: 1326807, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38689871

RESUMO

Modern sensing technologies and data analysis methods usher in a new era for sports training and practice. Hidden insights can be uncovered and interactive training environments can be created by means of data analysis. We present a system to support volleyball training which makes use of Inertial Measurement Units, a pressure sensitive display floor, and machine learning techniques to automatically detect relevant behaviours and provides the user with the appropriate information. While working with trainers and amateur athletes, we also explore potential applications that are driven by automatic action recognition, that contribute various requirements to the platform. The first application is an automatic video-tagging protocol that marks key events (captured on video) based on the automatic recognition of volleyball-specific actions with an unweighted average recall of 78.71% in the 10-fold cross-validation setting with convolution neural network and 73.84% in leave-one-subject-out cross-validation setting with active data representation method using wearable sensors, as an exemplification of how dashboard and retrieval systems would work with the platform. In the context of action recognition, we have evaluated statistical functions and their transformation using active data representation besides raw signal of IMUs sensor. The second application is the "bump-set-spike" trainer, which uses automatic action recognition to provide real-time feedback about performance to steer player behaviour in volleyball, as an example of rich learning environments enabled by live action detection. In addition to describing these applications, we detail the system components and architecture and discuss the implications that our system might have for sports in general and for volleyball in particular.

14.
J Neuroeng Rehabil ; 10: 31, 2013 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-23517757

RESUMO

BACKGROUND: Current inertial motion capture systems are rarely used in biomedical applications. The attachment and connection of the sensors with cables is often a complex and time consuming task. Moreover, it is prone to errors, because each sensor has to be attached to a predefined body segment. By using wireless inertial sensors and automatic identification of their positions on the human body, the complexity of the set-up can be reduced and incorrect attachments are avoided.We present a novel method for the automatic identification of inertial sensors on human body segments during walking. This method allows the user to place (wireless) inertial sensors on arbitrary body segments. Next, the user walks for just a few seconds and the segment to which each sensor is attached is identified automatically. METHODS: Walking data was recorded from ten healthy subjects using an Xsens MVN Biomech system with full-body configuration (17 inertial sensors). Subjects were asked to walk for about 6 seconds at normal walking speed (about 5 km/h). After rotating the sensor data to a global coordinate frame with x-axis in walking direction, y-axis pointing left and z-axis vertical, RMS, mean, and correlation coefficient features were extracted from x-, y- and z-components and magnitudes of the accelerations, angular velocities and angular accelerations. As a classifier, a decision tree based on the C4.5 algorithm was developed using Weka (Waikato Environment for Knowledge Analysis). RESULTS AND CONCLUSIONS: After testing the algorithm with 10-fold cross-validation using 31 walking trials (involving 527 sensors), 514 sensors were correctly classified (97.5%). When a decision tree for a lower body plus trunk configuration (8 inertial sensors) was trained and tested using 10-fold cross-validation, 100% of the sensors were correctly identified. This decision tree was also tested on walking trials of 7 patients (17 walking trials) after anterior cruciate ligament reconstruction, which also resulted in 100% correct identification, thus illustrating the robustness of the method.


Assuntos
Algoritmos , Reconstrução do Ligamento Cruzado Anterior/reabilitação , Árvores de Decisões , Monitorização Ambulatorial/métodos , Caminhada , Tecnologia sem Fio , Adulto , Feminino , Humanos , Masculino , Monitorização Ambulatorial/instrumentação , Tecnologia sem Fio/instrumentação , Adulto Jovem
15.
J Biomed Inform ; 45(3): 544-56, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22406009

RESUMO

A mobile patient monitoring system makes use of mobile computing and wireless communication technologies for continuous or periodic measurement and analysis of biosignals of a mobile patient. In a number of trials these systems have demonstrated their user-friendliness, convenience and effectiveness for both patients and healthcare professionals. In this paper we propose a generic architecture, associated terminology and a classificatory framework for comparing mobile patient monitoring systems. We then apply this comparison framework to classify six mobile patient monitoring systems selected according to the following criteria: use of diverse mobile communication techniques, evidence of practical trials and availability of sufficient published scientific information. We also show how to use this framework to determine feature sets of prospective real-time mobile patient monitoring systems using the example of epilepsy monitoring. This paper is aimed at both healthcare professionals and computer professionals. For healthcare professionals, this paper provides a general understanding of technical aspects of the mobile patient monitoring systems and highlights a number of issues implied by the use of these systems. The proposed framework for comparing mobile patient monitoring systems can be used by healthcare professionals to determine feature sets of prospective mobile patient monitoring systems to address particular healthcare related needs. Computer professionals are expected to benefit by gaining an understanding of the latest developments in the important emerging application area of mobile patient monitoring systems.


Assuntos
Monitorização Fisiológica/métodos , Registros Eletrônicos de Saúde , Epilepsia/epidemiologia , Humanos , Telemedicina/métodos
16.
IEEE Int Conf Rehabil Robot ; 2022: 1-6, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36176085

RESUMO

Measuring gait and balance recovery is necessary post stroke. In an earlier study, we developed a minimal three Inertial Measurement Units (IMUs) system called Portable Gait Lab (PGL). The PGL used the Centroidal Moment Pivot (CMP) assumption to estimate relative foot and centre of mass (CoM) positions, and thereby estimate gait parameters in healthy participants. In this study, we validate the feasibility of the PGL to track foot and CoM trajectory during gait in four persons with chronic stroke. Spatiotemporal gait and balance measures were estimated from the foot and CoM trajectories, and compared with the reference ForceShoes™. Each participant made at least 20 steps, and the PGL was able to track foot and CoM trajectories with a root mean square of the differences with the reference of 2.9 ± 0.2 cm and 4.6 ± 3.6 cm. The distances between either foot at the end of the walking task, and step lengths were estimated by PGL with an average error with the reference of 1.98 ± 2.2 cm and 7.8 ± 0.1 cm respectively across participants. We show that our approach was able to estimate spatiotemporal and balance parameters related to gait quality in a clinically useful manner. We recommend conducting further studies to study the feasibility of using the PGL system for variable gait patterns measured post stroke.


Assuntos
Marcha , Acidente Vascular Cerebral , Humanos , Fenômenos Biomecânicos , , Caminhada
17.
IEEE J Transl Eng Health Med ; 9: 2100211, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33344099

RESUMO

BACKGROUND: Stroke is one of the main causes of disability in the world, causing loss of motor function on mainly one side of the body. A proper assessment of motor function is required to help to direct and evaluate therapy. Assessment is currently performed by therapists using observer-based standardized clinical assessment protocols. Sensor-based technologies can be used to objectively quantify the presence and severity of motor impairments in stroke patients. METHODS: In this work, a minimally obstructive distributed inertial sensing system, intended to measure kinematics of the upper extremity, was developed and tested in a pilot study, where 10 chronic stroke subjects performed the arm-related tasks from the Fugl-Meyer Assessment protocol with the affected and non-affected side. RESULTS: The pilot study showed that the developed distributed measurement system was adequately sensitive to show significant differences in stroke subjects' arm postures between the affected and non-affected side. The presence of pathological synergies can be analysed using the measured joint angles of the upper limb segments, that describe the movement patterns of the subject. CONCLUSION: Features measured by the system vary from the assessed FMA-UE sub-score showing its potential to provide more detailed clinical information.


Assuntos
Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Projetos Piloto , Recuperação de Função Fisiológica , Acidente Vascular Cerebral/diagnóstico , Extremidade Superior
18.
Diabetes Care ; 2021 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-34301732

RESUMO

OBJECTIVE: To investigate glucose variations associated with glycated hemoglobin (HbA1c) in insulin-treated patients with type 2 diabetes. RESEARCH DESIGN AND METHODS: Patients included in Diabetes and Lifestyle Cohort Twente (DIALECT)-2 (n = 79) were grouped into three HbA1c categories: low, intermediate, and high (≤53, 54-62, and ≥63 mmol/mol or ≤7, 7.1-7.8, and ≥7.9%, respectively). Blood glucose time in range (TIR), time below range (TBR), time above range (TAR), glucose variability parameters, day and night duration, and frequency of TBR and TAR episodes were determined by continuous glucose monitoring (CGM) using the FreeStyle Libre sensor and compared between HbA1c categories. RESULTS: CGM was performed for a median (interquartile range) of 10 (7-12) days/patient. TIR was not different for low and intermediate HbA1c categories (76.8% [68.3-88.2] vs. 76.0% [72.5.0-80.1]), whereas in the low category, TBR was higher and TAR lower (7.7% [2.4-19.1] vs. 0.7% [0.3-6.1] and 8.2% [5.7-17.6] vs. 20.4% [11.6-27.0], respectively, P < 0.05). Patients in the highest HbA1c category had lower TIR (52.7% [40.9-67.3]) and higher TAR (44.1% [27.8-57.0]) than the other HbA1c categories (P < 0.05), but did not have less TBR during the night. All patients had more (0.06 ± 0.06/h vs. 0.03 ± 0.03/h; P = 0.002) and longer (88.0 [45.0-195.5] vs. 53.4 [34.4-82.8] minutes; P < 0.001) TBR episodes during the night than during the day. CONCLUSIONS: In this study, a high HbA1c did not reduce the occurrence of nocturnal hypoglycemia, and low HbA1c was not associated with the highest TIR. Optimal personalization of glycemic control requires the use of newer tools, including CGM-derived parameters.

19.
IEEE Trans Neural Syst Rehabil Eng ; 28(10): 2255-2264, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32816676

RESUMO

Ambulatory estimation of gait and balance parameters requires knowledge of relative feet and centre of mass (CoM) positions. Inertial measurement units (IMU) placed on each foot, and on the pelvis are useful in tracking these segments over time, but cannot track the relative distances between these segments. Further, drift due to strapdown inertial navigation results in erroneous relative estimates of feet and CoM positions after a few steps. In this study, we track the relative distances using the assumptions of the Centroidal Moment Pivot (CMP) theory. An Extended Kalman filter approach was used to fuse information from different sources: strapdown inertial navigation, commonly used constraints such as zero velocity updates, and relative segment distances from the CMP assumption; to eventually track relative feet and CoM positions. These estimates were expressed in a reference frame defined by the heading of each step. The validity of this approach was tested on variable gait. The step lengths and step widths were estimated with an average absolute error of 4.6±1.5 cm and 3.8±1.5 cm respectively when compared against the reference VICON©. Additionally, we validated the relative distances of the feet and the CoM, and further, show that the approach proves useful in identifying asymmetric gait patterns. We conclude that a three IMU approach is feasible as a portable gait lab for ambulatory measurement of foot and CoM positions in daily life.


Assuntos
Algoritmos , Marcha , , Humanos , Pelve
20.
IEEE Trans Neural Syst Rehabil Eng ; 28(6): 1308-1316, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32310775

RESUMO

Ground Reaction Forces (GRF) during gait are measured using expensive laboratory setups such as in-floor or treadmill force plates. Ambulatory measurement of GRF using wearables enables remote monitoring of gait and balance. Here, we propose using an Inertial Measurement Unit (IMU) mounted on the pelvis to estimate the GRF during gait in daily life. Calibration procedures and an Error State Extended Kalman filter (EEKF) were used to transform the accelerations at the center of mass (CoM) to the 3D GRF. The instantaneous 3D GRF was estimated for different overground walking patterns and compared with the 3D GRF measured using the reference ForceShoe™ system. Furthermore, we introduce a changing reference frame called the current step frame that followed the direction of each step made. The frame was defined using movement of the feet, and the estimated GRF were expressed in this new frame. This allowed direct comparison and validation with the reference. The mean and standard deviation of error between the estimated instantaneous 3D GRF and the reference, normalized against the range of the reference, was 12.1 ± 3.3% across all walking tasks, in the horizontal plane. The error margins show that a single pelvis IMU could be a minimal and ambulatory sensing alternative for estimating the instantaneous 3D components of GRF during overground gait.


Assuntos
Marcha , Laboratórios , Fenômenos Biomecânicos , Humanos , Pelve , Caminhada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA