Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiology ; 310(2): e231319, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38319168

RESUMO

Filters are commonly used to enhance specific structures and patterns in images, such as vessels or peritumoral regions, to enable clinical insights beyond the visible image using radiomics. However, their lack of standardization restricts reproducibility and clinical translation of radiomics decision support tools. In this special report, teams of researchers who developed radiomics software participated in a three-phase study (September 2020 to December 2022) to establish a standardized set of filters. The first two phases focused on finding reference filtered images and reference feature values for commonly used convolutional filters: mean, Laplacian of Gaussian, Laws and Gabor kernels, separable and nonseparable wavelets (including decomposed forms), and Riesz transformations. In the first phase, 15 teams used digital phantoms to establish 33 reference filtered images of 36 filter configurations. In phase 2, 11 teams used a chest CT image to derive reference values for 323 of 396 features computed from filtered images using 22 filter and image processing configurations. Reference filtered images and feature values for Riesz transformations were not established. Reproducibility of standardized convolutional filters was validated on a public data set of multimodal imaging (CT, fluorodeoxyglucose PET, and T1-weighted MRI) in 51 patients with soft-tissue sarcoma. At validation, reproducibility of 486 features computed from filtered images using nine configurations × three imaging modalities was assessed using the lower bounds of 95% CIs of intraclass correlation coefficients. Out of 486 features, 458 were found to be reproducible across nine teams with lower bounds of 95% CIs of intraclass correlation coefficients greater than 0.75. In conclusion, eight filter types were standardized with reference filtered images and reference feature values for verifying and calibrating radiomics software packages. A web-based tool is available for compliance checking.


Assuntos
Processamento de Imagem Assistida por Computador , Radiômica , Humanos , Reprodutibilidade dos Testes , Biomarcadores , Imagem Multimodal
2.
Eur J Radiol ; 172: 111346, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38309217

RESUMO

PURPOSE: To assess the inter-reader reproducibility of radiomics features on multiple MRI sequences after segmentations of colorectal liver metastases (CRLM). METHOD: 30 CRLM (in 23 patients) were manually delineated by three readers on MRI before the start of chemotherapy on the contrast enhanced T1-weighted images (CE-T1W) in the portal venous phase, T2-weighted images (T2W) and b800 diffusion weighted images (DWI). DWI delineations were copied to the ADC-maps. 107 radiomics features were extracted per sequence. The intraclass correlation coefficient (ICC) was calculated per feature. Features were considered reproducible if ICC > 0.9. RESULTS: 90% of CE-T1W features were reproducible with a median ICC of 0.98 (range 0.76-1.00). 81% of DWI features were robust with median ICC = 0.97 (range 0.38-1.00). The T2W features had a median ICC of 0.96 (range 0.55-0.99) and were reproducible in 80%. ADC showed the lowest number of reproducible features with 58% and median ICC = 0.91 (range 0.38-0.99) When considering the lower bound of the ICC 95% confidence intervals, 58%, 66%, 54% and 29% reached 0.9 for the CE-T1W, DWI, T2W and ADC features, respectively. The feature class with the best reproducibility differed per sequence. CONCLUSIONS: The majority of MRI radiomics features from CE-T1W, T2W, DWI and ADC in colorectal liver metastases were robust for segmentation variability between readers. The CE-T1W yielded slightly better reproducibility results compared to DWI and T2W. The ADC features seem more susceptible to reader differences compared to the other three sequences.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Radiômica , Imageamento por Ressonância Magnética/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Colorretais/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA