1.
Neth Heart J ; 32(7-8): 283-289, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38865067

RESUMO

INTRODUCTION: When electrical storm (ES) is amenable to neither antiarrhythmic drugs, nor deep sedation or catheter ablation, autonomic modulation may be considered. We report our experience with percutaneous left stellate ganglion block (PSGB) to temporarily suppress refractory ventricular arrhythmia (VA) in patients with structural heart disease. METHODS: A retrospective analysis was performed at our institution of patients with structural heart disease and an implantable cardioverter defibrillator (ICD) who had undergone PSGB for refractory VA between January 2018 and October 2021. The number of times antitachycardia pacing (ATP) was delivered and the number of ICD shocks/external cardioversions performed in the week before and after PSGB were evaluated. Charts were checked for potential complications. RESULTS: Twelve patients were identified who underwent a combined total of 15 PSGB and 5 surgical left cardiac sympathetic denervation procedures. Mean age was 73 ± 5.8 years and all patients were male. Nine of 12 (75%) had ischaemic cardiomyopathy, with the remainder having non-ischaemic dilated cardiomyopathy. Mean left ventricular ejection fraction was 35% (±â€¯12.2%). Eight of 12 (66.7%) patients were already being treated with both amiodarone and beta-blockers. The reduction in ATP did not reach statistical significance (p = 0.066); however, ICD shocks (p = 0.028) and ATP/shocks combined were significantly reduced (p = 0.04). At our follow-up electrophysiology meetings PSGB was deemed ineffective in 4 of 12 patients (33%). Temporary anisocoria was seen in 2 of 12 (17%) patients, and temporary hypotension and hoarseness were reported in a single patient. DISCUSSION: In this limited series, PSGB showed promise as a method for temporarily stabilising refractory VA and ES in a cohort of male patients with structural heart disease. The side effects observed were mild and temporary.

2.
Circulation ; 145(5): 321-329, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34779221

RESUMO

BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) showed noninferiority of subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous implantable cardioverter defibrillator (TV-ICD) with regard to inappropriate shocks and complications. In contrast to TV-ICD, S-ICD cannot provide antitachycardia pacing for monomorphic ventricular tachycardia. This prespecified secondary analysis evaluates appropriate therapy and whether antitachycardia pacing reduces the number of appropriate shocks. METHODS: The PRAETORIAN trial was an international, investigator-initiated randomized trial that included patients with an indication for implantable cardioverter defibrillator (ICD) therapy. Patients with previous ventricular tachycardia <170 bpm or refractory recurrent monomorphic ventricular tachycardia were excluded. In 39 centers, 849 patients were randomized to receive an S-ICD (n=426) or TV-ICD (n=423) and were followed for a median of 49.1 months. ICD programming was mandated by protocol. Appropriate ICD therapy was defined as therapy for ventricular arrhythmias. Arrhythmias were classified as discrete episodes and storm episodes (≥3 episodes within 24 hours). Analyses were performed in the modified intention-to-treat population. RESULTS: In the S-ICD group, 86 of 426 patients received appropriate therapy, versus 78 of 423 patients in the TV-ICD group, during a median follow-up of 52 months (48-month Kaplan-Meier estimates 19.4% and 17.5%; P=0.45). In the S-ICD group, 83 patients received at least 1 shock, versus 57 patients in the TV-ICD group (48-month Kaplan-Meier estimates 19.2% and 11.5%; P=0.02). Patients in the S-ICD group had a total of 254 shocks, compared with 228 shocks in the TV-ICD group (P=0.68). First shock efficacy was 93.8% in the S-ICD group and 91.6% in the TV-ICD group (P=0.40). The first antitachycardia pacing attempt successfully terminated 46% of all monomorphic ventricular tachycardias, but accelerated the arrhythmia in 9.4%. Ten patients with S-ICD experienced 13 electrical storms, versus 18 patients with TV-ICD with 19 electrical storms. Patients with appropriate therapy had an almost 2-fold increased relative risk of electrical storms in the TV-ICD group compared with the S-ICD group (P=0.05). CONCLUSIONS: In this trial, no difference was observed in shock efficacy of S-ICD compared with TV-ICD. Although patients in the S-ICD group were more likely to receive an ICD shock, the total number of appropriate shocks was not different between the 2 groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/normas , Idoso , Arritmias Cardíacas/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
3.
Eur Heart J ; 43(47): 4872-4883, 2022 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-36030464

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. METHODS AND RESULTS: The PRAETORIAN trial is an international, multicentre, randomized trial in which 849 patients with an indication for ICD therapy were randomized to receive an S- ICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections, and the need for invasive interventions. Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group, 49 complications occurred in 44 patients of which lead dysfunction was most frequent (HR: 0.69; P = 0.11). In both groups, half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared with the TV-ICD group (P < 0.001, P = 0.03, respectively). Significantly more complications required invasive interventions in the TV-ICD group compared with the S-ICD group (8.3% vs. 4.3%, HR: 0.59; P = 0.047). CONCLUSION: This secondary analysis shows that lead-related complications and systemic infections are more prevalent in the TV-ICD group compared with the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision-making in clinical practice.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Humanos , Resultado do Tratamento , Desfibriladores Implantáveis/efeitos adversos
4.
J Stroke Cerebrovasc Dis ; 32(12): 107400, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37801878

RESUMO

OBJECTIVES: Guidelines advise cardiac rhythm monitoring for 3 up to 30 days for detecting atrial fibrillation (AF) in patients with ischemic stroke of undetermined cause. However, the optimal monitoring duration is unknown. We aimed to determine the AF detection rate during 7-day outpatient cardiac rhythm monitoring in this patient group. METHODS: Participants from a large tertiary hospital in a prospective observational study (ATTEST) underwent outpatient cardiac rhythm monitoring after a negative standard diagnostic evaluation (i.e., 12-lead electrocardiogram and in-hospital telemetry). Primary outcome was the rate of newly detected AF. RESULTS: We examined 373 patients [age: 67.8±11.6 years; women: 166(44.5%); stroke: 278(74.5%)]. Median monitoring duration was 7 days (Inter Quartile Range (IQR) 7-7), performed after median of 36 days (IQR 27-47). AF was newly detected in 17(4.6%) patients, 5.4% of patients with ischemic stroke and 2.1% of patients with TIA. 53% of AF was detected on day-1, after day-3 73% of new AF was found. First AF episodes were detected up to day-7. Diabetes and increasing age were independent predictors of new AF. CONCLUSION: After ischemic stroke or TIA of undetermined cause, 7-day outpatient cardiac rhythm monitoring detected new AF in 4.6%. Patients with AF had significantly more cardiovascular risk factors. Although about 50% of first AF episodes occurred during the first day of monitoring, new AF was detected up to day-7, implying that the recommended minimum of 3 days cardiac rhythm monitoring after ischemic stroke of undetermined cause is insufficient. Subsequent long-term rhythm monitoring should be considered in selected patients.


Assuntos
Fibrilação Atrial , Ataque Isquêmico Transitório , AVC Isquêmico , Acidente Vascular Cerebral , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Ataque Isquêmico Transitório/complicações , Ataque Isquêmico Transitório/diagnóstico , AVC Isquêmico/complicações , Pacientes Ambulatoriais , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Estudos Prospectivos
5.
N Engl J Med ; 380(16): 1499-1508, 2019 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-30883054

RESUMO

BACKGROUND: Patients with recent-onset atrial fibrillation commonly undergo immediate restoration of sinus rhythm by pharmacologic or electrical cardioversion. However, whether immediate restoration of sinus rhythm is necessary is not known, since atrial fibrillation often terminates spontaneously. METHODS: In a multicenter, randomized, open-label, noninferiority trial, we randomly assigned patients with hemodynamically stable, recent-onset (<36 hours), symptomatic atrial fibrillation in the emergency department to be treated with a wait-and-see approach (delayed-cardioversion group) or early cardioversion. The wait-and-see approach involved initial treatment with rate-control medication only and delayed cardioversion if the atrial fibrillation did not resolve within 48 hours. The primary end point was the presence of sinus rhythm at 4 weeks. Noninferiority would be shown if the lower limit of the 95% confidence interval for the between-group difference in the primary end point in percentage points was more than -10. RESULTS: The presence of sinus rhythm at 4 weeks occurred in 193 of 212 patients (91%) in the delayed-cardioversion group and in 202 of 215 (94%) in the early-cardioversion group (between-group difference, -2.9 percentage points; 95% confidence interval [CI], -8.2 to 2.2; P = 0.005 for noninferiority). In the delayed-cardioversion group, conversion to sinus rhythm within 48 hours occurred spontaneously in 150 of 218 patients (69%) and after delayed cardioversion in 61 patients (28%). In the early-cardioversion group, conversion to sinus rhythm occurred spontaneously before the initiation of cardioversion in 36 of 219 patients (16%) and after cardioversion in 171 patients (78%). Among the patients who completed remote monitoring during 4 weeks of follow-up, a recurrence of atrial fibrillation occurred in 49 of 164 patients (30%) in the delayed-cardioversion group and in 50 of 171 (29%) in the early-cardioversion group. Within 4 weeks after randomization, cardiovascular complications occurred in 10 patients and 8 patients, respectively. CONCLUSIONS: In patients presenting to the emergency department with recent-onset, symptomatic atrial fibrillation, a wait-and-see approach was noninferior to early cardioversion in achieving a return to sinus rhythm at 4 weeks. (Funded by the Netherlands Organization for Health Research and Development and others; RACE 7 ACWAS ClinicalTrials.gov number, NCT02248753.).


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Cardioversão Elétrica , Tempo para o Tratamento , Antagonistas Adrenérgicos beta/uso terapêutico , Idoso , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Bloqueadores dos Canais de Cálcio/uso terapêutico , Digoxina/uso terapêutico , Cardioversão Elétrica/efeitos adversos , Serviço Hospitalar de Emergência , Feminino , Frequência Cardíaca , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Recidiva , Resultado do Tratamento
6.
Pacing Clin Electrophysiol ; 43(10): 1173-1179, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32901950

RESUMO

BACKGROUND: In the 123-study, we prospectively assessed, in a randomized fashion, the minimal cryoballoon application time necessary to achieve pulmonary vein (PV) isolation (PVI) in patients with paroxysmal atrial fibrillation (AF) with the aim to reduce complications by shortening the application duration. The first results of this study demonstrated that shortened cryoballoon applications (<2 minutes) resulted in less phrenic nerve injury (PNI) without compromising acute isolation efficacy for the right PVs. We now report the 1-year follow-up results regarding safety and efficacy of shorter cryoballoon applications. METHODS: A total of 222 patients with AF were randomized to two applications of 1 min "short," 2 min "medium," or 3 min "long" duration, 74 per group. Recurrence of AF and PV reconduction at 1-year follow-up were assessed. RESULTS: The overall 1-year freedom from AF was 79% and did not differ significantly between the short, medium, and long application groups (77%, 74%, and 85% for short, medium, and long application groups, respectively; P = 0.07). In 30 patients, a redo PVI procedure was performed. For all four PVs, there was no significant difference in reconduction between the three groups. Reconduction was most common in the left superior PV (57%). The right superior PV (RSPV) showed significantly less reconduction (17%) compared to the other PVs. CONCLUSIONS: Shortening cryoballoon applications of the RSPV to <2 minutes results in less PNI, while acute success and 1-year freedom from AF are not compromised. Therefore, shorter cryoballoon applications (especially) in the RSPV could be used to reduce PNI.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Nervo Frênico/lesões , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Fatores de Tempo
7.
Pacing Clin Electrophysiol ; 42(5): 508-514, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30756393

RESUMO

BACKGROUND: The second-generation cryoballoon significantly improves outcome of pulmonary vein isolation (PVI) but may cause more complications than the first generation. Currently, no consensus regarding optimal cryoballoon application time exists. The 123-study aimed to assess the minimal cryoballoon application duration necessary to achieve PVI (primary endpoint) and the effect of application duration on prevention of phrenic nerve injury (PNI). METHODS: Patients <75 years of age with paroxysmal atrial fibrillation, normal PV anatomy, and left atrial size <40 cc/m² or <50 mm were randomized to two applications of different duration: "short," "medium," or "long." A total of 222 patients were enrolled, 74 per group. RESULTS: Duration per application was 105 (101-108), 164 (160-168), and 224 (219-226) s and isolation was achieved in 79, 89, and 90% (P < 0.001) of the PVs after two applications in groups short, medium, and long, respectively. Only for the left PVs, the success rate of the short group was significantly less compared to the medium- and long-duration groups (P < 0.001). PNI during the procedure occurred in 19 PVs (6.5%) in the medium and in 20 PVs (6.8%) in the long duration groups compared to only five PVs (1.7%) in the short duration group (P < 0.001). CONCLUSIONS: Short cryoballoon ablation application times, less than 2 min, did affect the success for the left PVs but not for the right PVs and resulted in less PNI. A PV tailored approach with shorter application times for the right PVs might be advocated.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Nervo Frênico/lesões , Veias Pulmonares/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
8.
Am Heart J ; 183: 49-53, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27979041

RESUMO

BACKGROUND: Current standard of care for patients with recent-onset atrial fibrillation (AF) in the emergency department aims at urgent restoration of sinus rhythm, although paroxysmal AF is a condition that resolves spontaneously within 24 hours in more than 70% of the cases. A wait-and-see approach with rate-control medication only and when needed cardioversion within 48 hours of onset of symptoms is hypothesized to be noninferior, safe, and cost-effective as compared with current standard of care and to lead to a higher quality of life. DESIGN: The ACWAS trial (NCT02248753) is an investigator-initiated, randomized, controlled, 2-arm noninferiority trial that compares a wait-and-see approach to the standard of care. Consenting adults with recent-onset symptomatic AF in the emergency department without urgent need for cardioversion are eligible for participation. A total of 437 patients will be randomized to either standard care (pharmacologic or electrical cardioversion) or the wait-and-see approach, consisting of symptom reduction through rate control medication until spontaneous conversion is achieved, with the possibility of cardioversion within 48 hours after onset of symptoms. Primary end point is the presence of sinus rhythm on 12-lead electrocardiogram at 4 weeks; main secondary outcomes are adverse events, total medical and societal costs, quality of life, and cost-effectiveness for 1 year. CONCLUSIONS: The ACWAS trial aims at providing evidence for the use of a wait-and-see approach for patients with recent-onset symptomatic AF in the emergency department.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Cardioversão Elétrica , Flecainida/uso terapêutico , Frequência Cardíaca , Conduta Expectante , Adulto , Anticoagulantes/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Eletrocardiografia , Serviço Hospitalar de Emergência , Feminino , Humanos , Infusões Intravenosas , Masculino , Metoprolol/uso terapêutico
9.
Europace ; 16(1): 88-91, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23913594

RESUMO

AIMS: The 5 French Sorin Hepta 4B lead is a bipolar transvenous pacemaker lead with a passive fixation mechanism. From 2003 to 2008, a total of 98 Sorin Hepta 4B right ventricular pacemaker leads were implanted in our hospital. We observed an unexpected high failure rate of this pacemaker lead. The aim of this study is to determine the performance of the Hepta 4B lead. METHODS AND RESULTS: A retrospective single-centre survey was conducted on the performance of all implanted Hepta 4B leads in our high-volume tertiary hospital. Information on all implants was stored in a database. Analysis of this database and patients' charts was performed to assess the rate of complications of all implanted Hepta 4B leads. Median time of follow-up was 5.49 (4.15-6.44) years. Of the 98 implanted Hepta 4B leads, 21 (21%) were replaced. A total of 18 (18%) leads showed electrical malfunction, leading to symptoms in five (5%) patients. Electrical malfunction included impedance change, threshold rise, and sensing problems. CONCLUSION: In this single-centre retrospective observation we report an extreme and unexpected failure rate of the Sorin Hepta lead. The most common complication was electrical dysfunction. The reason for this phenomenon has to be analysed, but the co-radial multifilar design, allowing a smaller diameter of the lead, may explain this finding.


Assuntos
Eletrodos Implantados/estatística & dados numéricos , Análise de Falha de Equipamento/estatística & dados numéricos , Falha de Equipamento/estatística & dados numéricos , Marca-Passo Artificial/estatística & dados numéricos , Idoso , Condutividade Elétrica , Feminino , Seguimentos , Humanos , Masculino , Países Baixos , Estudos Retrospectivos
10.
Clin Cardiol ; 47(1): e24161, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37872853

RESUMO

BACKGROUND: In the Rate Control versus Electrical Cardioversion Trial 7-Acute Cardioversion versus Wait and See, patients with recent-onset atrial fibrillation (AF) were randomized to either early or delayed cardioversion. AIM: This prespecified sub-analysis aimed to evaluate heart rate during AF recurrences after an emergency department (ED) visit identified by an electrocardiogram (ECG)-based handheld device. METHODS: After the ED visit, included patients (n = 437) were asked to use an ECG-based handheld device to monitor for recurrences during the 4-week follow-up period. 335 patients used the handheld device and were included in this analysis. Recordings from the device were collected and assessed for heart rhythm and rate. Optimal rate control was defined as a target resting heart rate of <110 beats per minute (bpm). RESULTS: In 99 patients (29.6%, mean age 67 ± 10 years, 39.4% female, median 6 [3-12] AF recordings) a total of 314 AF recurrences (median 2 [1-3] per patient) were identified during follow-up. The average median resting heart rate at recurrence was 100 ± 21 bpm in the delayed vs 112 ± 25 bpm in the early cardioversion group (p = .011). Optimal rate control was seen in 68.4% [21.3%-100%] and 33.3% [0%-77.5%] of recordings (p = .01), respectively. Randomization group [coefficient -12.09 (-20.55 to -3.63, p = .006) for delayed vs. early cardioversion] and heart rate on index ECG [coefficient 0.46 (0.29-0.63, p < .001) per bpm increase] were identified on multivariable analysis as factors associated with lower median heart rate during AF recurrences. CONCLUSION: A delayed cardioversion strategy translated into a favorable heart rate profile during AF recurrences.


Assuntos
Fibrilação Atrial , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Cardioversão Elétrica , Eletrocardiografia , Frequência Cardíaca , Recidiva , Ensaios Clínicos Controlados Aleatórios como Assunto
11.
Nat Med ; 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38977913

RESUMO

Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), for which pre-clinical and early-stage clinical data are suggestive of some degree of preferentiality to myocardial tissue ablation without damage to adjacent structures. Here in the MANIFEST-17K study we assessed the safety of PFA by studying the post-approval use of this treatment modality. Of the 116 centers performing post-approval PFA with a pentaspline catheter, data were received from 106 centers (91.4% participation) regarding 17,642 patients undergoing PFA (mean age 64, 34.7% female, 57.8% paroxysmal AF and 35.2% persistent AF). No esophageal complications, pulmonary vein stenosis or persistent phrenic palsy was reported (transient palsy was reported in 0.06% of patients; 11 of 17,642). Major complications, reported for ~1% of patients (173 of 17,642), were pericardial tamponade (0.36%; 63 of 17,642) and vascular events (0.30%; 53 of 17,642). Stroke was rare (0.12%; 22 of 17,642) and death was even rarer (0.03%; 5 of 17,642). Unexpected complications of PFA were coronary arterial spasm in 0.14% of patients (25 of 17,642) and hemolysis-related acute renal failure necessitating hemodialysis in 0.03% of patients (5 of 17,642). Taken together, these data indicate that PFA demonstrates a favorable safety profile by avoiding much of the collateral damage seen with conventional thermal ablation. PFA has the potential to be transformative for the management of patients with AF.

12.
Ann Noninvasive Electrocardiol ; 18(6): 564-70, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24303971

RESUMO

BACKGROUND: Although atrial fibrillation (AF) is the most commonly encountered arrhythmia, some of the properties make its detection challenging. In daily practice, underdiagnosis can lead to less effective treatment in prevention of stroke. Based on data from studies on treatment of AF, more intensive follow-up strategies, including 7-day Holter recording, 30-day event recording, and even implantable cardiac monitoring devices, are suggested. The study purpose is to evaluate the performance of a continuous single-channel loop recorder with automatic AF detection and transtelephonic electrocardiogram (ECG) transmission capabilities. METHODS AND RESULTS: A consecutive cohort of 153 patients admitted to the stroke unit with a presumptive diagnosis of ischemic cerebrovascular accident was screened for AF. Twenty-four-hour rhythm observation was performed using a single-channel external loop recorder (ELR) configured for automated AF detection. A total of 45 patients with a known history of AF, AF on the admission ECG, or incomplete registrations were excluded. Extensive additional frequency-based settings were used to establish a reference registration. In total, 2923 recordings were transmitted. We evaluated all events, of which 1190 were designated by the device as AF. The sensitivity, specificity, PPV, and NPV for identifying AF using the ELR were, respectively, 93%, 51%, 5%, and 99%. CONCLUSIONS: In this ELR validation study, the dedicated AF detection algorithm showed to be highly sensitive but not specific for AF. Applicability of an ELR might be limited for efficacious detection of AF, as manual verification is mandatory for a vast amount of recordings.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Telemetria/métodos , Idoso , Eletrocardiografia Ambulatorial/estatística & dados numéricos , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes
13.
Europace ; 14(8): 1161-4, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22431444

RESUMO

AIMS: Recently, concerns about St Jude's Riata lead family have come to light. We present three cases of patients with Riata internal cardioverter defibrillator (ICD) leads with externalized conductors. METHODS AND RESULTS: All patients had the same insulation defect, with externalized conductors, but differed in presentation and symptoms. These cases, which form 3 of 179 (1.68%) of our total Riata lead population, presented four or more years after implantation. This may be an indication that the problem with the Riata lead may well be greater than reported in the recent St Jude Medical device advisory letter. CONCLUSION: The management of the Riata lead problem is discussed as, up until now, management of patients with an implanted Riata lead has been based on detecting electric abnormalities on regular ICD interrogation only.


Assuntos
Desfibriladores Implantáveis , Falha de Equipamento , Idoso , Eletrodos Implantados , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco
14.
Europace ; 14(3): 431-6, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21946817

RESUMO

INTRODUCTION: A number of predisposing factors have been suggested to be contributing to drug-induced torsade de pointes (TdP) arrhythmias: short-long-short (SLS) sequence, bradycardia, timing of drug administration, anaesthesia, ventricular remodelling, and altered ventricular activation due to ventricular ectopic beats (SLS) or idioventricular rhythm (IVR). Chronic atrio-ventricular (AV)-block (CAVB) dogs are susceptible to dofetilide-induced TdP. METHODS AND RESULTS: In 32 anaesthetized animals, the relevance of ventricular remodelling for TdP susceptibility was studied by dofetilide [0.025 mg/kg/5 min intravenously (iv)] during bradycardia in the presence (CAVB, n= 18) or absence [acute atrio-ventricular block (AVB), n= 32] of ventricular remodelling. In sub-protocols, the possible pro-arrhythmic effects of timing of dofetilide administration: prior to (n= 11), or after creation of AVB (n= 9) and relevance of SLS pacing (n= 17) was investigated during IVR. Dofetilide was also given after AVB when the activation of the ventricles was normal: pacing (1000 ms) from the high septum (n= 7) or abnormal but fixed from the left ventricular apex (n= 5). Torsade de pointes inducibility was defined as reproducible (≥ 3 times) occurrence. In acute AV block (AAVB), dofetilide did not induce TdP spontaneously (0 of 32), whereas TdP was seen in 10 out of 18 serially tested dogs in CAVB (P< 0.001). The other factors: timing of dofetilide (0 of 11 vs. 0 of 9), SLS pacing (0 of 17 vs. 1 of 17), or ventricular activation (0 of 7 vs. 0 of 5) did not increase TdP susceptibility. Beat-to-beat variability of repolarization increased after ventricular remodelling and was highest prior to TdP induction. CONCLUSION: In AAVB dogs, TdP is not spontaneously seen, whereas it is present in CAVB. This implies that ventricular remodelling is a prerequisite for TdP induction in this model.


Assuntos
Antiarrítmicos/efeitos adversos , Bloqueio Atrioventricular/fisiopatologia , Fenetilaminas/efeitos adversos , Sulfonamidas/efeitos adversos , Torsades de Pointes/induzido quimicamente , Remodelação Ventricular/fisiologia , Animais , Bradicardia/fisiopatologia , Cães , Feminino , Masculino , Torsades de Pointes/fisiopatologia , Remodelação Ventricular/efeitos dos fármacos
15.
Heart ; 109(1): 26-33, 2022 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-36322782

RESUMO

OBJECTIVE: The Rate Control versus Electrical Cardioversion Trial 7-Acute Cardioversion versus Wait and See trial compared early to delayed cardioversion for patients with recent-onset symptomatic atrial fibrillation (AF). This study aims to evaluate the adherence to a 4-week mobile health (mHealth) prescription to detect AF recurrences after an emergency department visit. METHODS: After the emergency department visit, the 437 included patients, irrespective of randomisation arm (early or delayed cardioversion), were asked to record heart rate and rhythm for 1 min three times daily and in case of symptoms by an electrocardiography-based handheld device for 4 weeks (if available). Adherence was appraised as number of performed measurements per number of recordings asked from the patient and was evaluated for longitudinal adherence consistency. All patients who used the handheld device were included in this subanalysis. RESULTS: 335 patients (58% males; median age 67 (IQR 11) years) were included. The median overall adherence of all patients was 83.3% (IQR 29.9%). The median number of monitoring days was 27 out of 27 (IQR 5), whereas the median number of full monitoring days was 16 out of 27 (IQR 14). Higher age and a previous paroxysm of AF were identified as multivariable adjusted factors associated with adherence. CONCLUSIONS: In this randomised trial, a 4-week mHealth prescription to monitor for AF recurrences after an emergency department visit for recent-onset AF was feasible with 85.7% of patients consistently using the device with at least one measurement per day. Older patients were more adherent. TRIAL REGISTRATION NUMBER: NCT02248753.


Assuntos
Fibrilação Atrial , Telemedicina , Masculino , Humanos , Idoso , Feminino , Fibrilação Atrial/terapia , Fibrilação Atrial/tratamento farmacológico , Antiarrítmicos/uso terapêutico , Frequência Cardíaca , Cardioversão Elétrica , Recidiva
16.
17.
Europace ; 12(11): 1648, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20543194

RESUMO

Oversensing of external electrical signals can cause inappropriate therapy in cardiac rhythm management devices. In this report, a patient with an implantable cardioverter-defibrillator (ICD) is presented, who received inappropriate shocks due to temporary epicardial pacing after cardiothoracic surgery.


Assuntos
Desfibriladores Implantáveis , Falha de Equipamento , Aneurisma Cardíaco/cirurgia , Insuficiência da Valva Mitral/cirurgia , Complicações Pós-Operatórias/fisiopatologia , Taquicardia Ventricular/etiologia , Idoso , Estimulação Cardíaca Artificial , Eletrocardiografia , Feminino , Frequência Cardíaca/fisiologia , Humanos , Volume Sistólico/fisiologia , Taquicardia Ventricular/fisiopatologia
19.
Eur Heart J Case Rep ; 4(FI1): 1-5, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33089050

RESUMO

BACKGROUND: Early studies have led to the repositioning of a subgroup of antimalarial agents (e.g. chloroquine and hydroxychloroquine) as antiviral treatment in coronavirus disease 2019 (COVID-19) patients. These drugs are now being prescribed based on small non-controlled studies, but larger controlled studies have yet to demonstrate the positive effect of these drugs. In addition, these drugs are also known for their QT interval-prolonging effect associated with significant morbidity and mortality. CASE SUMMARY: We present a case of a 66-year-old female admitted to the intensive care unit with respiratory failure due to COVID-19. She was treated with chloroquine (QTc interval at baseline was 429 ms). Despite cessation of chloroquine, but after the start of erythromycin, she developed severe QTc interval prolongation (QTc interval 550 ms) and 'Torsade de Pointes'. Two weeks after cessation of all QTc interval-prolonging drugs, the QTc interval was restored. DISCUSSION: The elimination half-life of chloroquine ranges from days up to weeks. Even after discontinuation of chloroquine, ECG monitoring in COVID-19 patients is warranted. We recommend observation of the QT interval after cessation of chloroquine in cases where other potentially QT interval-prolonging drugs are introduced.

20.
Europace ; 11(12): 1702-4, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19700778

RESUMO

Para-Hisian pacing at high output simultaneously captures the His bundle or proximal right bundle, as well as the adjacent ventricular myocardium. At lower output, direct His-bundle, or right-bundle, capture is lost which causes an increase in the stimulus to atrium interval. We describe a case with an increment of 68 ms with capture of the His bundle. This seems to be a paradoxical response, which however can be explained by the presence of retrograde dual AV-node physiology. Continuation of this phenomenon could be related to concealed anterograde invasion of the fast pathway thereby maintaining the retrograde activation during para-Hisian pacing on the slow pathway despite paced cycle lengths (His to His intervals) where retrograde fast pathway conduction proved to be possible.