Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Urol ; : 101097JU0000000000004051, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38787799

RESUMO

PURPOSE: To assess the oncological outcomes of sentinel-node dissection during radical prostatectomy according to nodal location in comparison to extended pelvic lymph node dissection. MATERIALS AND METHODS: Prospectively collected data of clinically node negative patients that underwent prostatectomy and extended lymph node dissection with or without sentinel-node from 2013 to January 2023 was retrospectively analyzed. The primary endpoint was to assess oncological outcomes on the whole population. Kaplan-Meier curves were used to depict biochemical and clinical recurrence free survival. Multivariable Cox regression models assessed the impact of nodal location on SPECT on oncological outcomes. Adjustment for case mix included: pathological T stage, ISUP grade group, initial PSA, nodal burden, age at surgery and surgical margin status. Secondarily, a propensity score match was performed according to age at surgery, PSA, biopsy ISUP, clinical T stage and Briganti risk of nodal invasion. Survival and regression analyses were than performed also in the matched population. RESULTS: 55.8% patients had at least one sentinel node outside of lymph node dissection template at SPECT/CT. Log-rank test showed comparable 36-months biochemical (P = .3) and clinical recurrence-free survival (P = .6) among patients with sentinel-node inside template, outside template or ePLND alone. At Cox regression, sentinel-node location outside template was associated with lower hazard of metastases (HR 0.62; P = .04) in the overall cohort, while in the matched cohort benefits were observed only for biochemical recurrence (HR 0.57; P = .001). CONCLUSIONS: Wider nodal resection boundaries outside "classic" template, driven by sentinel node procedure, have a positive impact on oncological outcomes in selected patient.

2.
Eur J Nucl Med Mol Imaging ; 50(9): 2861-2871, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37036490

RESUMO

OBJECTIVE: To determine the diagnostic accuracy of the hybrid tracer indocyanine green (ICG)-Technetium-99 m(99mTc)-nanocolloid compared to sequential tracers of 99mTc-nanocolloid and free-ICG in detecting tumor-positive lymph nodes (LN) during primary surgery in prostate cancer (PCa) patients. INTRODUCTION: Image-guided surgery strategies can help visualize individual lymphatic drainage patterns and sentinel lymph nodes (SLNs) in PCa patients. For lymphatic mapping radioactive, fluorescent and hybrid tracers are being clinically exploited. In this prospective randomized phase II trial, we made a head-to-head comparison between ICG-99mTc-nanocolloid (hybrid group) and 99mTc-nanocolloid and subsequent free-ICG injection (sequential group). METHODS: PCa patients with a >5% risk of lymphatic involvement according to the 2012 Briganti nomogram and planned for prostatectomy were included and randomized (1:1) between ultrasound-guided intraprostatic tracer administration of ICG-99mTc-nanocolloid (n = 69) or 99mTc-nanocolloid (n = 69) 5 h before surgery. Preoperative lymphoscintigraphy and SPECT/CT were performed to define the locations of the SLNs. Additionally, all participants in the sequential group received an injection of free-ICG at time of surgery. Subsequently, all (S)LNs were dissected using fluorescence guidance followed by an extended pelvic lymph node dissection (ePLND). The primary outcome was the total number of surgically removed (S)LNs and tumor-positive (S)LNs. RESULTS: The total number of surgically removed (S)LN packages was 701 and 733 in the hybrid and sequential groups, respectively (p = 0.727). The total number of fluorescent LNs retrieved was 310 and 665 nodes in the hybrid and sequential groups, respectively (p < 0.001). However, no statistically significant difference was observed in the corresponding number of tumor-positive nodes among the groups (44 vs. 33; p = 0.470). Consequently, the rate of tumor-positive fluorescent LNs was higher in the hybrid group (7.4%) compared to the sequential group (2.6%; p = 0.002), indicating an enhanced positive predictive value for the hybrid approach. There was no difference in complications within 90 days after surgery (p = 0.78). CONCLUSIONS: The hybrid tracer ICG-99mTc-nanocolloid improved the positive predictive value for tumor-bearing LNs while minimizing the number of fluorescent nodes compared to the sequential tracer approach. Consequently, the hybrid tracer ICG-99mTc-nanocolloid enables the most reliable and minimal invasive method for LN staging in PCa patients.


Assuntos
Neoplasias da Próstata , Linfonodo Sentinela , Masculino , Humanos , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/cirurgia , Linfonodo Sentinela/patologia , Biópsia de Linfonodo Sentinela/métodos , Estudos Prospectivos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/patologia , Excisão de Linfonodo , Verde de Indocianina , Agregado de Albumina Marcado com Tecnécio Tc 99m , Linfonodos/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA