1.
Am J Obstet Gynecol ; 230(3S): S932-S946.e3, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38462264

RESUMO

BACKGROUND: Decreasing rates of assisted vaginal birth have been paralleled with increasing rates of cesarean deliveries over the last 40 years. The OdonAssist is a novel device for assisted vaginal birth. Iterative changes to clinical parameters, device design, and technique have been made to improve device efficacy and usability. OBJECTIVE: This study aimed to determine if the feasibility, safety, and efficacy of the OdonAssist device were sufficient to justify conducting a future randomized controlled trial. STUDY DESIGN: An open-label nonrandomized study of 104 participants having a clinically indicated assisted vaginal birth using the OdonAssist was undertaken at Southmead Hospital, Bristol, United Kingdom. Data were also collected from participants who consented to participate in the study but for whom trained OdonAssist operators were not available, providing a nested cohort. The primary clinical outcome was the proportion of births successfully expedited with the OdonAssist. Secondary outcomes included clinical, patient-reported, operator-reported, device and health care utilization. Neonatal outcome data were reviewed at day 28, and maternal outcomes were investigated up to day 90. Given that the number of successful OdonAssist births was ≥61 out of 104, the hypothesis of a poor rate of 50% was rejected in favor of a good rate of ≥65%. RESULTS: Between August 2019 and June 2021, 941 (64%) of the 1471 approached, eligible participants consented to participate. Of these, 104 received the OdonAssist intervention. Birth was assisted in all cephalic vertex fetal positions, at all stations ≥1 cm below the ischial spines (with or without regional analgesia). The OdonAssist was effective in 69 of the 104 (66%) cases, consistent with the hypothesis of a good efficacy rate. There were no serious device-related maternal or neonatal adverse reactions, and there were no serious adverse device effects. Only 4% of neonatal soft tissue bruising in the successful OdonAssist group was considered device-related, as opposed to 20% and 23% in the unsuccessful OdonAssist group and the nested cohort, respectively. Participants reported high birth perception scores. All practitioners found the device use to be straightforward. CONCLUSION: Recruitment to an interventional study of a new device for assisted vaginal birth is feasible; 64% of eligible participants were willing to participate. The success rate of the OdonAssist was comparable to that of the Kiwi OmniCup when introduced in the same unit in 2002, meeting the threshold for a randomized controlled trial to compare the OdonAssist with current standard practice. There were no disadvantages of study participation in terms of maternal and neonatal outcomes. There were potential advantages of using the OdonAssist, particularly reduced neonatal soft tissue injury. The same application technique is used for all fetal positions, with all operators deeming the device straightforward to use. This study provides important data to inform future study design.


Assuntos
Cesárea , Cabeça , Feminino , Recém-Nascido , Gravidez , Humanos , Reino Unido , Vagina
2.
BJOG ; 124 Suppl 4: 10-18, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28940873

RESUMO

OBJECTIVE: To investigate (1) the placement of the BD Odon Device on the model fetal head and (2) perineal distention during simulated operative vaginal births conducted with the BD Odon Device. DESIGN: Observational simulation study. SETTING: North Bristol NHS Trust, UK. POPULATION OR SAMPLE: Four hundred and forty simulated operative vaginal births. METHODS: Three bespoke fetal mannequins were developed to represent (1) bi-parietal diameter of the 50th centile at term, (2) bi-parietal diameter at the 5th centile at term, and (3) 50th centile head with 2 cm of caput. Siting of the BD Odon Device on model heads was determined before and after 400 simulated operative vaginal births. Variables were analysed to determine their effect on device siting and movement during birth. The fetal mannequins were placed inside a maternal mannequin and the BD Odon Device was placed around the fetal head as per the instructions for use. The location of the air cuff was determined before and after the head was delivered. Perineal distension was determined by recording maximum perineal distention during a simulated operative vaginal birth using the same procedure, as well as scenarios employing an inappropriately non-deflated air cuff (for the BD Odon Device), the Kiwi ventouse and non-rotational forceps. MAIN OUTCOME MEASURES: Site and displacement during birth of the BD Odon Device on a model head. Maximal perineal distension during birth. RESULTS: The BD Odon Device was reliably sited in a standard over the fetal head position (approximately 40 mm above the fetal chin) for all stations, head sizes and positions with no significant displacement. In occipito-posterior births, compared with occipito-anterior or transverse, the BD Odon Device routinely sited further down the fetal head (toward the chin). The BD Odon Device was not associated with more perineal distension compared with forceps or Kiwi ventouse (respectively 21, 26 and 21 mm at posterior fourchette). CONCLUSIONS: The BD Odon Device reliably sited over a safe area of the fetal head in 400 simulated births representative of clinical practice. The BD Odon Device generates similar levels of perineal distension compared with Kiwi ventouse when used correctly. TWEETABLE ABSTRACT: Location of the BD Odon Device on a fetal head in simulation.


Assuntos
Extração Obstétrica/instrumentação , Apresentação no Trabalho de Parto , Períneo/fisiologia , Extração Obstétrica/métodos , Feminino , Feto/fisiologia , Cabeça/fisiologia , Humanos , Manequins , Gravidez
3.
BJOG ; 124 Suppl 4: 35-43, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28940874

RESUMO

OBJECTIVE: To (1) determine how intended users interact with and use the BD Odon Device in simulation, (2) use these findings to alter progressively the design of the BD Odon Device and (3) validate that these changes have improved the ability of practitioners to use the BD Odon Device. DESIGN: Human factors evaluation study. SETTING: Simulation suite designed to mimic delivery room. POPULATION OR SAMPLE: Three hundred and ninety simulated operative births, performed by 100 practising clinicians. METHODS: Simulated operative vaginal births performed using the BD Odon Device and the device Instructions for use were subjected to three formative human factors evaluations and one human factors validation test. Following each evaluation, findings were reviewed and the design of the BD Odon Device and Instructions for use were modified. MAIN OUTCOME MEASURES: Successful performance of an operative vaginal birth using the BD Odon Device in accordance with provided training and Instructions for use. RESULTS: Using version two of the BD Odon Device, and following exposure to face-to-face training and written instructions, 25% of accouchers were able successfully to perform a simulated operative vaginal birth. In the final evaluation, following device design and training material alterations, all accouchers were able successfully to perform a simulated operative vaginal birth using version four of the BD Odon Device. CONCLUSIONS: Human factors evaluations have enabled a multi-professional device and training materials design team to alter the design of the BD Odon Device and the Instructions for use in an evidence-based fashion. This process has resulted in a device which has a predictable and likely safe pattern of use. TWEETABLE ABSTRACT: Human Factors evaluations help make the BD Odon Device safe and usable for clinical practice.


Assuntos
Extração Obstétrica/instrumentação , Treinamento por Simulação , Adulto , Idoso , Desenho de Equipamento , Docentes de Medicina/educação , Feminino , Humanos , Masculino , Manequins , Pessoa de Meia-Idade , Enfermeiros Obstétricos/educação , Obstetrícia/educação , Gravidez , Distribuição Aleatória
4.
BJOG ; 124 Suppl 4: 26-34, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28940870

RESUMO

OBJECTIVE: The BD Odon Device™ is a new instrument for operative vaginal birth with potential for preventing maternal, fetal and newborn morbidity/mortality during a complicated second stage of labour. The device is a plastic sleeve with an air chamber inflated around the baby's head which is gently pulled through the birth canal. The aim was to monitor changes in cerebral circulation during constriction of the neck to evaluate a risk of potential malposition of the device. DESIGN: Randomised prospective study. POPULATION OR SAMPLE: Twelve newborn piglets. METHODS: The anaesthetised piglets were exposed to hypoxia until base excess was -20 mmol/l and/or mean arterial blood pressure had decreased to 20 mmHg. At reoxygenation, an air chamber was inflated around the neck to 300 mmHg and the piglets randomised into three groups: 10 (n = 5), 5 (n = 5) or 2 (n = 2) minutes' occlusion. Cerebral perfusion was evaluated with transcranial contrast-enhanced ultrasound at four time-points, and analysed in the carotid arteries, basal ganglia, cortex and whole brain. Statistical analysis used ANOVA, linear mixed model, Kruskal-Wallis H-test. MAIN OUTCOME MEASURES: Perfusion parameters; peak intensity, time to peak intensity, upslope, mean transit time, area under the curve. RESULTS: The haemodynamic response was comparable between groups. Perfusion parameters showed a slight increase at end hypoxia followed by a decrease during occlusion, especially in the cortex (P = 0.00-0.2). After deflation, perfusion returned towards baseline values. CONCLUSIONS: Simulation of malposition of the Odon Device was performed using a newborn hypoxic piglet model. Considerable compression of the neck vessels was applied, with only a moderate decrease in perfusion and with restoration of haemodynamics/cerebral perfusion after decompression. TWEETABLE ABSTRACT: Malposition of Odon Device™ in a piglet model revealed a reversible decrease in cerebral perfusion during neck constriction.


Assuntos
Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Extração Obstétrica/instrumentação , Hipóxia-Isquemia Encefálica/diagnóstico por imagem , Animais , Animais Recém-Nascidos , Meios de Contraste , Feminino , Modelos Animais , Gravidez , Distribuição Aleatória , Hexafluoreto de Enxofre , Suínos , Ultrassonografia
5.
Trials ; 20(1): 159, 2019 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-30836979

RESUMO

BACKGROUND: Assisted vaginal birth is a vital health intervention that can result in better outcomes for mothers and their babies when complications arise in the second stage of labour. Unfortunately, instruments for assisted vaginal birth (forceps and ventouse) are often not utilised in settings where there is most clinical need, resulting in maternal and neonatal morbidity and mortality which could have been prevented. The BD Odon Device is a new device for assisted vaginal birth that may be able to address this unmet need. However, before dissemination, the device requires evaluation in robust clinical trials. A feasibility study to investigate the clinical impact, safety, and acceptability of the BD Odon Device for assisted vaginal birth is therefore planned. This will provide further information on acceptability, recruitment, and the outcome data required to design a future randomised controlled trial of the BD Odon Device versus Kiwi ventouse. METHODS: Forty women who require an assisted vaginal birth for a recognised clinical indication will have the birth assisted with the BD Odon Device. The primary outcome is successful vaginal birth completed with the BD Odon Device. Secondary clinical outcomes include maternal and neonatal outcomes, and maternal and practitioner satisfaction. Safety data will be reviewed following every birth. DISCUSSION: A future randomised controlled trial of the BD Odon Device versus the current standard instrument (the Kiwi ventouse) is planned. The findings of the ASSIST Study will inform the randomised controlled trial design. TRIAL REGISTRATION: ISRCTN, ISRCTN10203171 . Prospectively registered on 27 July 2018.