Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 177
Filtrar
1.
Ann Surg Oncol ; 31(10): 6546-6550, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38995449

RESUMO

BACKGROUND: Because of the complex anatomy of the right posterior hepatic pedicle, there have been few reports on standardized laparoscopic portal territory staining-guided anatomical resection of liver segment 6 (LPTAR-S6). This study aimed to elucidate the indocyanine green (ICG) fluorescence staining methods for LPTAR-S6. PATIENTS AND METHODS: LPTAR-S6 can be performed using positive and negative fluorescence staining approaches. We implemented these two approaches for patients with hepatocellular carcinoma. Descriptions of the surgical strategy and technical details are presented. RESULTS: Two patients safely underwent LPTAR-S6 using a preoperative three-dimensional reconstruction plan. The intraoperative ICG fluorescence staining effect was satisfactory, and the anatomical landmarks were fully exposed. CONCLUSIONS: A detailed preoperative three-dimensional reconstruction plan, complete intraoperative application of real-time laparoscopic ultrasound guidance, and ICG fluorescence staining can result in accurate transection of the liver parenchyma during LPTAR-S6.


Assuntos
Carcinoma Hepatocelular , Corantes , Hepatectomia , Verde de Indocianina , Laparoscopia , Neoplasias Hepáticas , Cirurgia Assistida por Computador , Humanos , Laparoscopia/métodos , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Hepatectomia/métodos , Masculino , Carcinoma Hepatocelular/cirurgia , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Cirurgia Assistida por Computador/métodos , Idoso , Pessoa de Meia-Idade , Fluorescência , Feminino , Imageamento Tridimensional/métodos , Prognóstico , Corantes Fluorescentes
2.
BMC Gastroenterol ; 24(1): 316, 2024 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-39289637

RESUMO

BACKGROUND: During esophagectomy, evaluation of blood supply to the gastric tube is critically important to estimate and avoid anastomotic complications. This retrospective study investigated the relationship between indocyanine green (ICG) fluorescence angiography during esophagectomy and postoperative endoscopy findings, especially mucosal color change. METHODS: This study retrospectively collected data from 86 patients who underwent subtotal esophagectomy and reconstruction using a gastric tube for esophageal cancer at the Tokyo Medical and Dental University between 2017 and 2020. The flow speed of ICG fluorescence in the gastric tube was evaluated during the operation. Additionally, the main root of ICG enhancement and pattern of ICG distribution in the gastric tube were evaluated. On postoperative day 1 (POD1), the change in the mucosal color to white, thought to reflect ischemia, or black, thought to reflect congestion of the proximal gastric tube, was evaluated. The correlations between these factors, clinical parameters, and surgical outcomes were evaluated. Univariate and multivariate analyses used logistic regression to identify the risk factors affecting mucosal color change. RESULTS: Multivariate analyses revealed that the only independent significant predictor of mucosal congestion on POD1 was the ICG enhancement time of the right gastric tube tip (odds ratio, 14.49; 95% confidential interval, 2.41-87.24; P = 0.004). CONCLUSIONS: This study indicated that the ICG enhancement time is related to venous malperfusion and congestion rather than arterial malperfusion and ischemia.


Assuntos
Neoplasias Esofágicas , Esofagectomia , Angiofluoresceinografia , Verde de Indocianina , Humanos , Esofagectomia/efeitos adversos , Esofagectomia/métodos , Masculino , Feminino , Estudos Retrospectivos , Neoplasias Esofágicas/cirurgia , Idoso , Pessoa de Meia-Idade , Angiofluoresceinografia/métodos , Corantes/administração & dosagem , Complicações Pós-Operatórias , Estômago/irrigação sanguínea , Estômago/cirurgia , Estômago/diagnóstico por imagem , Fluxo Sanguíneo Regional , Anastomose Cirúrgica/efeitos adversos
3.
Surg Endosc ; 38(7): 4048-4056, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38806956

RESUMO

BACKGROUND: Laparoscopic left hemihepatectomy (LLH) has been shown to be an effective and safe method for treating hepatolithiasis primarily affecting the left hemiliver. However, this procedure still presents challenges. Due to pathological changes in intrahepatic duct stones, safely dissecting the hilar vessels and determining precise resection boundaries remains difficult, even with fluorescent imaging. Our team proposed a new method of augmented reality navigation (ARN) combined with Indocyanine green (ICG) fluorescence imaging for LLH in hepatolithiasis cases. This study aimed to investigate the feasibility of this combined approach in the procedure. METHODS: Between May 2021 and September 2023, 16 patients with hepatolithiasis who underwent LLH were included. All patients underwent preoperative 3D evaluation and were then guided using ARN and ICG fluorescence imaging during the procedure. Perioperative and short-term postoperative outcomes were assessed to evaluate the safety and efficacy of the method. RESULTS: All 16 patients successfully underwent LLH. The mean operation time was 380.31 ± 92.17 min, with a mean estimated blood loss of 116.25 ± 64.49 ml. ARN successfully aided in guiding hilar vessel dissection in all patients. ICG fluorescence imaging successfully identified liver resection boundaries in 11 patients (68.8%). In the remaining 5 patients (31.3%) where fluorescence imaging failed, virtual liver segment projection (VLSP) successfully identified their resection boundaries. No major complications occurred in any patients. Immediate stone residual rate, stone recurrence rate, and stone extraction rate through the T-tube sinus tract were 12.5%, 6.3%, and 6.3%, respectively. CONCLUSION: The combination of ARN and ICG fluorescence imaging enhances the safety and precision of LLH for hepatolithiasis. Moreover, ARN may serve as a safe and effective tool for identifying precise resection boundaries in cases where ICG fluorescence imaging fails.


Assuntos
Realidade Aumentada , Hepatectomia , Verde de Indocianina , Laparoscopia , Hepatopatias , Imagem Óptica , Humanos , Hepatectomia/métodos , Laparoscopia/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto , Hepatopatias/cirurgia , Hepatopatias/diagnóstico por imagem , Imagem Óptica/métodos , Idoso , Cirurgia Assistida por Computador/métodos , Estudos de Viabilidade , Duração da Cirurgia , Corantes , Resultado do Tratamento
4.
Surg Endosc ; 38(1): 193-201, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37957299

RESUMO

BACKGROUND: Segmental or subsegmental anatomical resection (AR) of hepatocellular carcinoma (HCC) in minimal access liver surgery (MALS) has been technically proposed. The Glissonean approach or dye injection technique are generally adopted. The tumor-feeding portal pedicle compression technique (C-AR) is an established approach in open surgery, but its feasibility in the MALS environment has never been described. METHODS: Eligible patients were prospectively enrolled to undergo laparoscopic or robotic ultrasound-guided C-AR based on HCC location and preoperative identification of a single tumor-feeding portal pedicle. Initial C-AR experience was gained with laparoscopic cases in the beginning of 2020. Following our progressive experience in laparoscopic C-AR, patients requiring AR for HCC were consecutively selected for robotic C-AR. RESULTS: A total of 10 patients underwent minimal access C-AR. All patients had Child-Pugh A HCC. The surgical procedures included 6 laparoscopic and 4 robotic C-AR. Median tumor size was 3.1 cm (range 2-7 cm). All procedures had R0 margin. Postoperative complications were nil. CONCLUSION: C-AR technique is a feasible and promising technique for patients eligible for laparoscopic and robotic AR for HCC. Further data are necessary to validate its applicability to more complex minimal access AR.


Assuntos
Carcinoma Hepatocelular , Laparoscopia , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Hepatectomia/métodos , Laparoscopia/métodos , Ultrassonografia de Intervenção
5.
Langenbecks Arch Surg ; 409(1): 147, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38695955

RESUMO

PURPOSE: To investigate the accuracy of laser speckle flowgraphy (LSFG), a noninvasive method for the quantitative evaluation of blood flow using mean blur rate (MBR) as a blood flow parameter in the assessment of bowel blood perfusion compared to indocyanine green fluorescence angiography (ICG-FA). METHODS: We enrolled 46 patients who underwent left-sided colorectal surgery. LSFG and ICG-FA were applied to assess blood bowel perfusion, with MBR and luminance as parameters, respectively. In both measurement methods, the position where the parameter suddenly decreased was defined as the blood flow boundary line. Subsequently, the blood flow boundaries created after processing the blood vessels flowing into the intestinal tract were determined using LSFG and ICG-FA, and concordance between the two was examined. Blood flow boundaries were visually identified using color tone changes on a color map created based on MBR in LSFG and using differences in luminance in ICG-FA. The distances between the transection line and blood flow boundaries determined using each method were compared. RESULTS: The location of blood flow boundaries matched in 65% (30/46) of cases. Although locations differed in the remaining 35% (16/46), all were located on the anal side near the transection line, and the difference was not clinically significant. The average distances between the transection line and blood flow boundary were 2.76 (SD = 3.25) and 3.71 (SD = 4.26) mm, respectively. There was no statistically significant difference between the two groups (p = 0.38). CONCLUSION: LSFG was shown to have comparable accuracy to ICG-FA, and may be useful for evaluating bowel perfusion.


Assuntos
Corantes , Angiofluoresceinografia , Verde de Indocianina , Humanos , Feminino , Angiofluoresceinografia/métodos , Masculino , Idoso , Pessoa de Meia-Idade , Imagem de Contraste de Manchas a Laser , Idoso de 80 Anos ou mais , Fluxo Sanguíneo Regional/fisiologia , Adulto , Intestinos/irrigação sanguínea , Velocidade do Fluxo Sanguíneo/fisiologia , Neoplasias Colorretais/cirurgia
6.
J Minim Invasive Gynecol ; 31(6): 496-503, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38493829

RESUMO

STUDY OBJECTIVE: To show feasibility and short-term outcomes of robot-assisted vaginal NOTES (RvNOTES) for the treatment of stage IV endometriosis during total hysterectomy with/without complete cul-de-sac obliteration. DESIGN: Retrospective case series. SETTING: Single academic tertiary care hospital in Houston, Texas, USA. PATIENTS: Twenty-three adult women with stage IV endometriosis. INTERVENTIONS: RvNOTES with total hysterectomy for excision of severe endometriosis. MEASUREMENTS AND MAIN RESULTS: Patients were assessed for various metrics including total operative time, robot dock time, robot console time, hysterectomy time, estimated blood loss, perioperative pain using the Visual Analogue Scale (VAS), and complications. The mean total operative time was 224.3 minutes. The study also found that patients with complete cul-de-sac obliteration had significantly longer operative times and higher estimated blood loss compared to those with partial or no obliteration. Postoperative VAS pain scores showed a significant reduction over a 6-week period. Complications included one case of complete ureteral transection, pelvic hematoma with infection, vaginal abscess, urinary tract infection, and pneumonia. CONCLUSION: Our findings suggest that RvNOTES may be a feasible surgical approach in expert hands for treating stage IV endometriosis, even in cases with complete obliteration of the cul-de-sac.


Assuntos
Endometriose , Estudos de Viabilidade , Cirurgia Endoscópica por Orifício Natural , Duração da Cirurgia , Procedimentos Cirúrgicos Robóticos , Humanos , Feminino , Endometriose/cirurgia , Adulto , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Retrospectivos , Projetos Piloto , Cirurgia Endoscópica por Orifício Natural/métodos , Pessoa de Meia-Idade , Histerectomia/métodos , Resultado do Tratamento , Escavação Retouterina/cirurgia , Perda Sanguínea Cirúrgica , Dor Pós-Operatória/etiologia
7.
Surg Today ; 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39085699

RESUMO

PURPOSE: This pilot study evaluated indocyanine green-guided near-infrared fluorescence (ICG-NIRF) imaging of testicular blood flow to predict long-term testicular atrophy after testicular torsion (TT) surgery. METHODS: The subjects of this retrospective study were patients who underwent surgery for TT at our hospital between December, 2020 and July, 2022. After detorsion, testicular blood flow was evaluated by ICG-NIRF imaging and classified into three categories: fluorescence detected, no fluorescence detected, and fluorescence detected only in the tunica albuginea vessels. Testicular volume was measured by ultrasonography up to 12 months after surgery to evaluate long-term outcomes. RESULTS: Twelve patients were included in this analysis. We found a 100% correlation between the absence of ICG-NIRF signals and subsequent testicular atrophy. In three patients without an ICG-NIRF signal, the median testis size 12 months postoperatively was significantly smaller (16.5% of the contralateral testis; range 13-20%) than that in six patients with an ICG-NIRF signal (96%; 89-115%) (p = 0.013). Mild atrophy (74.5%; 73-76%) was also observed in the three patients for whom an ICG-NIRF signal was detected only in the tunica albuginea vessels. CONCLUSIONS: Our pilot study highlights the potential of ICG-NIRF imaging as a prognostic tool for guiding surgical decision-making for patients with TT, by predicting postoperative testicular atrophy.

8.
Am J Otolaryngol ; 45(4): 104343, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38729013

RESUMO

OBJECTIVE: Landmark arteries during endoscopic sinus surgery are currently identified on the basis of anatomy, CT imaging and navigation, and Doppler flowmetry. However, the advantage of intraoperative fluorescence imaging during endoscopic sinus surgery has not been demonstrated. This study aimed to investigate whether Indocyanine Green (ICG) is useful for visualizing landmark arteries during endoscopic sinus and skull base surgery. METHODS: Eight patients who underwent endoscopic sinus and pituitary surgeries and consented to study participation were included. After planned procedures were performed as usual, landmark arteries were examined by ICG endoscope. Recorded video and preoperative CT images were analyzed for identification of five landmark arteries: anterior ethmoidal artery (AEA), posterior ethmoidal artery (PEA), internal carotid artery (ICA), sphenopalatine artery (SPA), and postnasal artery (PNA). Identification of arteries was evaluated three grades: identifiable, locatable, unrecognizable. RESULTS: Eight patients and eleven sides were evaluated. The ICG dose was 2.5 mg/body and a single shot was sufficient for evaluation. 100 % of AEA was identified (9/9 sides), 86 % of PNA (6/7 sides), 56 % of ICA (5/9 sides), and 25 % of PEA and SPA (2/8 sides). CONCLUSION: ICG could visualize landmark arteries, even thin arteries like AEA, during endoscopic sinus and skull base surgeries. Visualization was affected by thickness of bone or soft tissue above arteries, blood clots, sensitivity setting, and angle and distance of near-infrared light irradiation. ICG visualization of landmark arteries may help avoid vascular injuries during endoscopic sinus and skull base surgeries, particularly of AEA, PNA and ICA.


Assuntos
Endoscopia , Verde de Indocianina , Seios Paranasais , Base do Crânio , Humanos , Endoscopia/métodos , Base do Crânio/cirurgia , Base do Crânio/diagnóstico por imagem , Base do Crânio/irrigação sanguínea , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Idoso , Seios Paranasais/cirurgia , Seios Paranasais/diagnóstico por imagem , Seios Paranasais/irrigação sanguínea , Artérias/diagnóstico por imagem , Pontos de Referência Anatômicos , Corantes/administração & dosagem , Tomografia Computadorizada por Raios X/métodos , Fluorescência , Imagem Óptica/métodos
9.
Zhonghua Nan Ke Xue ; 30(7): 604-610, 2024 Jul.
Artigo em Zh | MEDLINE | ID: mdl-39212394

RESUMO

OBJECTIVE: To investigate the clinical application value of injection of indocyanine green (ICG) via vasopuncture in fluorescence laparoscopic radical prostatectomy (FLRP). METHODS: We retrospectively analyzed the clinical data on 50 cases of PCa treated by injection of ICG via vasopuncture in FLRP. The patients were aged (70.60 ± 5.67) years old, with an average PSA value of (18.42 ± 2.69) µg/L. During the operation, we injected ICG at 0.5 ml by vasopuncture through the vas deferens at each side of the scrotum, observed the visualized images of the vas deferens and seminal vesicles using normal high-definition, black-and-white fluorescence, green fluorescence, and color fluorescence respectively, and then isolated the adherent seminal vesicles under the laparoscope. RESULTS: A total of 93 injections of ICG were completed, 86 bilaterally, 4 on the right and 3 on the left. The vas deferens and seminal vesicles were visualized in 41 cases (60 sides, 64.52%), 19 bilaterally, 7 on the right and 15 on the left. Spillage of the fluorescent agent occurred in 9 cases during the incision of the bladder neck and adhesion of the seminal vesicles was found intraoperatively in 10 cases, in which the seminal vesicles were all quickly located by fluorescence visualization. No rectal injury occurred during the surgery. Mild scrotal subcutaneous bruises were observed in 2 cases, with a postoperative pathological Gleason's score of 7.44 ± 0.88. CONCLUSION: Injection of ICG by vasopuncture is minimally invasive and safe. ICG-mediated near-infrared imaging and real-time fluorescence imaging of the vas deferens and seminal vesicles can achieve precise positioning and removal of the seminal vesicles and prostate gland without causing rectal injury.


Assuntos
Verde de Indocianina , Laparoscopia , Prostatectomia , Neoplasias da Próstata , Humanos , Masculino , Prostatectomia/métodos , Laparoscopia/métodos , Idoso , Estudos Retrospectivos , Neoplasias da Próstata/cirurgia , Ducto Deferente/cirurgia , Glândulas Seminais , Fluorescência , Pessoa de Meia-Idade
10.
Esophagus ; 2024 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-39304552

RESUMO

AIM: This study aimed to investigate the effectiveness of a modified incision line on the lesser curvature for gastric conduit formation during esophagectomy in enhancing the perfusion of gastric conduit as determined by indocyanine green fluorescence imaging and reducing the incidence of anastomotic leakage. METHODS: A total of 272 patients who underwent esophagectomy at our institute between 2014 and 2022 were enrolled in this study. These patients were divided based on two different types of cutlines on the lesser curvature: conventional group (n = 141) following the traditional cutline and modified group (n = 131) adopting a modified cutline. Gastric conduit perfusion was assessed by ICG fluorescence imaging, and clinical outcomes after esophagectomy were evaluated. RESULTS: The distance from the pylorus to the cutline was significantly longer in the modified group compared with the conventional group (median: 9.0 cm vs. 5.0 cm, p < 0.001). The blood flow speed in the gastric conduit wall was significantly higher in the modified group than that in the conventional group (median: 2.81 cm/s vs. 2.54 cm/s, p = 0.001). Furthermore, anastomotic leakage was significantly lower (p = 0.024) and hospital stay was significantly shorter (p < 0.001) in the modified group compared with the conventional group. Multivariate analysis identified blood flow speed in the gastric conduit wall as the only variable significantly associated with anastomotic leakage. CONCLUSIONS: ICG fluorescence imaging is a feasible, reliable method for the assessment of gastric conduit perfusion. Modified lesser curvature cutline could enhance gastric conduit perfusion, promote blood circulation around the anastomotic site, and reduce the risk of anastomotic leakage after esophagectomy.

11.
Int J Colorectal Dis ; 38(1): 7, 2023 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-36625972

RESUMO

PURPOSE: The purpose of this study was to clarify the usefulness of indocyanine green fluorescence imaging (ICG-FI) in the assessment of intestinal vascular perfusion in patients who receive intracorporeal anastomosis (IA) in colon cancer surgery. METHODS: This was a single-center, retrospective study using propensity score matching. We compared the surgical outcomes of colon cancer patients who underwent laparoscopic colonic resection with IA or external anastomosis (EA) with the intraoperative evaluation of anastomotic perfusion using ICG-FI from January 2019 to July 2021. The detection rate of poor anastomotic perfusion by ICG-FI was examined. RESULTS: A total of 223 patients were enrolled. After matching, 69 patients each were classified into the IA and EA groups. There were no significant differences in age, sex, body mass index, tumor localization, or progression between the two groups. The operation time was similar (172 min vs. 171 min, p = 0.62) and the amount of bleeding was significantly lower (0 ml vs. 2 ml, p = 0.0023) in the IA group. The complication rates (grade ≥ 2) of the two groups were similar (14.5% vs. 11.6%, p = 0.59). ICG-FI identified four patients (5.8%) with poor anastomotic perfusion in the IA group, but none in the EA group (p = 0.046). All four patients with poor perfusion in the IA group underwent additional resection; none of these patients developed postoperative complications. CONCLUSION: Poor anastomotic perfusion was detected in 5.8% of cases who underwent laparoscopic colon cancer surgery with IA. ICG-FI is useful for evaluating anastomotic perfusion in IA in order to prevent AL.


Assuntos
Neoplasias do Colo , Neoplasias Colorretais , Laparoscopia , Humanos , Verde de Indocianina , Neoplasias Colorretais/cirurgia , Estudos Retrospectivos , Fístula Anastomótica/etiologia , Neoplasias do Colo/diagnóstico por imagem , Neoplasias do Colo/cirurgia , Neoplasias do Colo/complicações , Anastomose Cirúrgica/efeitos adversos , Laparoscopia/efeitos adversos , Perfusão/efeitos adversos , Imagem Óptica/efeitos adversos , Imagem Óptica/métodos
12.
Pediatr Transplant ; 27(3): e14431, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36419241

RESUMO

BACKGROUND: The intraoperative identification of a bile leak after liver transplantation can be challenging, especially when using technical variant grafts. Possible sources of leakage include the sometimes multiple biliary anastomoses or orphan ducts leading to cut surface leak. Preoperative imaging is often unable to precisely identify the location of the leak. Indocyanine green (ICG) fluorescence imaging has been utilized in adult hepatobiliary and transplant surgery, but not for the management of postoperative biliary complications. METHODS: We present a case where ICG fluorescence imaging was used to identify a cut surface bile leak after pediatric split liver transplantation. RESULTS: A 5-year-old girl with methylmalonic acidemia underwent a left lobe split liver transplantation. A single Roux-en-Y choledochojejunostomy was performed. Nine days after transplant, bile was noted in the surgical drain. Imaging confirmed the patency of the hepatic artery and the absence of intraabdominal collection. A hepatobiliary iminodiacetic acid scan showed the majority of radiotracer was excreted through the surgical drain. The patient was explored surgically: 4.5× loupe magnification did not allow for the localization of the leak. ICG was administered intravenously, after which a cut surface bile leak could be identified and repaired. There was no recurrence of bile leak after repair. Eighteen months after transplant, the patient is alive and well and has not suffered from any additional biliary complications. CONCLUSION: Indocyanine green constitutes an additional tool in the arsenal of measures available to facilitate the intraoperative detection and management of bile leaks occurring after pediatric technical variant graft transplant.


Assuntos
Doenças Biliares , Sistema Biliar , Transplante de Fígado , Adulto , Feminino , Humanos , Criança , Pré-Escolar , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Verde de Indocianina , Fígado/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/cirurgia , Imagem Óptica
13.
Artif Organs ; 47(1): 77-87, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35957489

RESUMO

BACKGROUND: Antithrombogenicity of extracorporeal membrane oxygenation (ECMO) devices, particularly oxygenators, is a current problem, with numerous studies and developments underway. However, there has been limited progress in developing methods to accurately compare the antithrombogenicity of oxygenators. Animal experiments are commonly conducted to evaluate the antithrombogenicity of devices; however, it is challenging to maintain a steady experimental environment. We propose an innovative experimental animal model to evaluate different devices in a constant experimental environment in real-time. METHODS: This model uses two venous-arterial ECMO circuits attached to one animal (one by jugular vein and carotid artery, one by femoral vein and artery) and real-time assessment of thrombus formation in the oxygenator by indocyanine green (ICG) fluorescence imaging. Comparison studies were conducted using three pigs: one to compare different oxygenators (MERA vs. CAPIOX) (Case 1), and two to compare antithrombotic properties of the oxygenator (QUADROX) when used under different hydrodynamic conditions (continuous flow vs. pulsatile flow) (Cases 2 and 3). RESULTS: Thrombi, visualized using ICG imaging, appeared as black dots on a white background in each oxygenator. In Case 1, differences in the site of thrombus formation and rate of thrombus growth were observed in real-time in two oxygenators. In Case 2 and 3, the thrombus region was smaller in pulsatile than in continuous conditions. CONCLUSIONS: We devised an innovative experimental animal model for comparison of antithrombogenicity in ECMO circuits. This model enabled simultaneous evaluation of two different ECMO circuits under the same biological conditions and reduced the number of sacrificed experimental animals.


Assuntos
Oxigenação por Membrana Extracorpórea , Trombose , Animais , Suínos , Verde de Indocianina , Desenho de Equipamento , Oxigenadores , Oxigenação por Membrana Extracorpórea/métodos , Modelos Animais , Trombose/etiologia , Imagem Óptica , Oxigenadores de Membrana/efeitos adversos
14.
Neurosurg Rev ; 46(1): 312, 2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-37996551

RESUMO

To assess the use of indocyanine green (ICG) fluorescence endoscopy to evaluate pituitary blood flow in craniopharyngioma resection and its possible impact on intraoperative decisions regarding pituitary stalk processing. Patients with craniopharyngiomas who had undergone transsphenoidal surgery since March 2021, when an ICG endoscope was introduced at the Kagoshima University Hospital, were included in the study. When targeted tumor removal was approaching completion, 10 mg of ICG was administered intravenously to evaluate blood flow in the pituitary stalk and gland. ICG signals and endocrinological status before and after surgery were evaluated retrospectively. Pituitary stalk and gland blood flow were evaluated as positive (++), weakly positive (+), and no signal (-).Ten patients with craniopharyngiomas underwent transsphenoidal surgery using an ICG endoscope (mean age 56.6 ± 14.2 years; 40% male). Among the eight patients in whom the pituitary stalk was preserved, pituitary function with positive signal on the stalk was intact in two. Two other patients with weakly positive stalk and positive pituitary gland signals showed intact function or minimal pituitary dysfunction. Four patients had impairments in more than three axes with poor ICG signals in the stalk or pituitary gland. Two patients underwent pituitary amputation because of high tumor invasion and lack of ICG signal in the stalk after tumor removal, resulting in panhypopituitarism. A negative ICG signal in the pituitary stalk is likely to indicate postoperative pituitary function loss. Craniopharyngioma surgery using ICG endoscopy may be useful for predicting endocrine prognosis and improving tumor outcomes.


Assuntos
Craniofaringioma , Neoplasias Hipofisárias , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Craniofaringioma/diagnóstico por imagem , Craniofaringioma/cirurgia , Craniofaringioma/patologia , Verde de Indocianina , Estudos Retrospectivos , Neoplasias Hipofisárias/cirurgia , Neoplasias Hipofisárias/patologia , Hipófise/diagnóstico por imagem , Hipófise/cirurgia , Endoscopia/métodos , Resultado do Tratamento
15.
Surg Innov ; 30(6): 770-778, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36840625

RESUMO

Background. Most of the available evidence on the use of indocyanine green (ICG) fluorescence in clinical practice consists of articles published by surgeons of the Asian-Pacific area. We performed a prospective cohort study to assess the patterns of ICG fluorescence in Western hepatocellular carcinoma (HCC) counterparts.Methods. From April 2019 to January 2022, a total of 31 consecutive patients who underwent laparoscopic liver resection (LLR) for superficial HCC were enrolled in this prospective study. All patients underwent laparoscopic staging with both laparoscopic ultrasound (LUS) and ICG fluorescence imaging.Results. A total of 38 hepatocellular carcinomas (HCCs) were enrolled: 23 superficial (surfacing at the liver's Glissonian capsule), 5 exophytic, 5 shallow (<8 mm from the hepatic surface) and 5 deep (>10 mm from the hepatic surface). The detection rate with preoperative imaging (abdominal CT/MRI), LUS, ICG fluorescence and combined modalities (ICG and LUS) was 97.4%, 94.9%, 89.7% and 100%, respectively. The five deep seated lesions underwent ultrasound-guided laparoscopic thermal ablation. The other 33 HCCs were treated with minimally invasive liver resection. Intraoperative ultrasound patterns were registered for each single nodule resected. The ICG fluorescence pattern was classified in two types: total fluorescence (all the tumoral tissue showed strong and homogeneous fluorescence), n = 9/33 (27.3%), and non-total fluorescence (partial and rim fluorescence), n = 24/33 (72.7%). There was a statistical correlation between ICG patterns and grade of differentiation. Almost all lesions with uniform fluorescence pattern were well-differentiated HCCs (G1-G2), while partial and rim-type fluorescence pattern were more common among moderately and poorly differentiated HCCs (G3-G4) (88.9% vs 11.1%, 37.5% vs 62.5%, P = .025, respectively).Conclusions. ICG fluorescence imaging could be used to identify early the grade of HCC, ie intraoperatively, thus influencing the intraoperative treatment.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Verde de Indocianina , Estudos Prospectivos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Hepatectomia/métodos , Imagem Óptica/métodos
16.
Aesthetic Plast Surg ; 47(Suppl 1): 28-31, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-35428917

RESUMO

Rectus muscles widened by pregnancy are handled in dramatically different ways in standard abdominoplasty and mesh abdominoplasty. Patients with significant abdominal wall laxity and/or umbilical hernia repair are treated with the use of retrorectus mesh placement. In these conditions the risk of damaging the blood supply to the umbilicus might be greater. Despite the fact that it is of no functional significance in adults, the umbilicus is a key esthetic landmark of the anterior abdominal wall. For both patients and surgeons alike, its absence, distortion, or misplacement after surgery can be distressing and can be a source of frequent patient complaint. Umbilical stalk necrosis represents an underreported yet important complication for patients following mesh abdominoplasty. We advance some recommendations for patients undergoing abdominoplasty with mesh repair of rectus diastasis and/or concomitant umbilical hernia mesh repair via the open approach. This information should help influence intraoperative decision-making to prevent the development of this undesirable complication.Level of Evidence V: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Abdominoplastia , Hérnia Umbilical , Adulto , Feminino , Gravidez , Humanos , Umbigo/cirurgia , Hérnia Umbilical/etiologia , Hérnia Umbilical/cirurgia , Telas Cirúrgicas , Abdominoplastia/efeitos adversos , Necrose/etiologia , Necrose/prevenção & controle , Necrose/cirurgia
17.
Medicina (Kaunas) ; 59(8)2023 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-37629746

RESUMO

Background and Objectives: Surgical treatment for primary hyperparathyroidism (PHPT) has evolved from bilateral exploration through a long transcervical incision to focused parathyroidectomy with a minimal incision above the pathologic gland. Recently, endoscopic or robot-assisted parathyroid surgery without direct neck incision has been introduced. The aim of this study was to investigate the effectiveness of indocyanine green (ICG) fluorescence as a new method for the visual identification of abnormal hyperfunctioning parathyroid glands in robot-assisted parathyroidectomy using FireflyTM technology. We also aimed to conduct a comparative analysis between robot-assisted parathyroidectomy and conventional focused parathyroidectomy in order to identify clinical differences between the two surgical approaches. Materials and Methods: A total of 37 patients with PHPT underwent parathyroidectomy at a single university hospital between September 2018 and December 2022. Thirty-one patients underwent open focused parathyroidectomy (open group), and six patients underwent robot-assisted parathyroidectomy (robot group). Pre-operative localization via parathyroid SPECT-CT and an intraoperative parathyroid hormone (IOPTH) assay were used to successfully remove the pathologic parathyroid in both groups. ICG was administered only in the robot group. Results: Pathologic parathyroid showed a persistent fluorescence pattern under near-infrared vision. After the removal of the fluorescent parathyroid gland, IOPTH was normalized in all six patients in the robot group. However, the open group showed shorter hospital stays (1.8 ± 1.2 vs. 3.0 ± 0.0 days, p < 0.001) and shorter operation times (91.1 ± 69.1 vs. 152.5 ± 23.6 min, p = 0.001) than the robot group. After 6 months of surgery, PTH, calcium, and ionized calcium levels were all normalized without significant differences between the groups. Conclusions: Robot-assisted parathyroidectomy using ICG is helpful for the visual identification of the pathologic parathyroid gland. The advantage of robot parathyroidectomy is a better cosmetic outcome. However, it still does not show better clinical outcomes than conventional open focused parathyroidectomy.


Assuntos
Hiperparatireoidismo Primário , Robótica , Humanos , Paratireoidectomia , Verde de Indocianina , Cálcio , Fluorescência , Hiperparatireoidismo Primário/cirurgia , Hormônio Paratireóideo
18.
Esophagus ; 20(1): 81-88, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35915195

RESUMO

PURPOSE: The thoracic inlet space might influence the blood vessel perfusion in the gastric conduit. The purpose of this study was to clarify the impacts of the thoracic inlet space on blood vessel perfusion in the gastric conduit and anastomotic leakage after esophagectomy. METHODS: One hundred and forty-two esophageal cancer patients underwent esophagectomy followed by gastric conduit reconstruction via the retrosternal route. The blood flow speed in the gastric conduit was measured using indocyanine green fluorescence before and after reconstruction. Parameters at the thoracic inlet space were measured using CT. We then investigated the correlation between these two parameters and whether they could predict anastomotic leakage after esophagectomy. RESULTS: Blood flow speed in the gastric conduit was slower after reconstruction than before reconstruction (P < 0.001). The incidence of anastomotic leakage (n = 23) was higher among patients with a delayed blood flow speed before reconstruction (n = 27) than among those with a non-delayed blood flow speed before reconstruction (n = 115) (P < 0.001). Among the patients with a non-delayed blood flow speed before reconstruction, the thoracic inlet area (TIA, sternum-tracheal distance × clavicle head distance) was positively correlated with the blood flow speed after reconstruction (P = 0.023) and was identified as an independent predictor of anastomotic leakage (P < 0.001). CONCLUSION: A narrow TIA was associated with a delayed blood flow speed in the gastric conduit after reconstruction and was capable of predicting anastomotic leakage in the patients with a non-delayed blood flow speed before reconstruction.


Assuntos
Fístula Anastomótica , Esofagectomia , Humanos , Fístula Anastomótica/epidemiologia , Fístula Anastomótica/etiologia , Esofagectomia/efeitos adversos , Fluorescência , Baías , Estômago/cirurgia , Estômago/irrigação sanguínea
19.
J Minim Access Surg ; 19(1): 165-167, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36722543

RESUMO

We report on a pure laparoscopic left lateral graft procurement with removing segment 3 that employs the Glissonean approach, indocyanine green (ICG) fluorescence imaging and in situ splitting. We first mobilised the liver and confirmed the root of the left hepatic vein (LHV). We then encircled the left Glissonean pedicle, and the segment 3 Glissonean pedicle (G3) was also individually encircled. We performed parenchymal transection of the left lateral segmentectomy using Pringle's manoeuvre. We clipped G3 and confirmed the demarcation line using ICG fluorescence imaging. The inflow in the S2 area was confirmed via intraoperative sonography, and we split segment 3 (S3) from the left lateral sector graft in situ. The left hepatic artery, left portal vein and left hepatic duct were also encircled and divided. The LHV was transected using a linear stapler, and the S2 monosegment liver graft and removed S3 were procured. Our technique reasonably prevents graft-related complications.

20.
Surg Endosc ; 36(1): 607-613, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33512630

RESUMO

BACKGROUND: Recent studies have reported the feasibility of indocyanine green fluorescence imaging of adrenal tumors to guide dissection. Although the adrenal has been reported to concentrate the dye more than surrounding tissues, the amount of tissue distinction and how this compares with conventional vision has not been quantified before. The aim of this study is to quantify this distinction using color analysis. METHODS: This was an institutional review board-approved retrospective study. By excluding adrenal cortical carcinoma, metastasis and pheochromocytoma, video recordings of 50 patients who underwent robotic transabdominal lateral adrenalectomy with indocyanine green (ICG) imaging for adrenocortical tumors between August 2015 and May 2018 were reviewed. Using a color analysis software, the pixel intensity of adrenal tumors versus adjacent retroperitoneal tissues was calculated for conventional red, green and blue, as well as indocyanine green (ICG) scales. Statistical analysis was performed using ANOVA. RESULTS: A total of 50 patients underwent unilateral robotic transabdominal lateral adrenalectomy. All procedures were completed robotically without a conversion to laparoscopy or open. Morbidity was 4%. Measured pixel intensity of adrenal tumors was higher than adjacent retroperitoneal tissues for all conventional color and ICG modes (p < 0.0001), with the gradient being more pronounced for ICG green versus conventional red, green and blue modes. CONCLUSIONS: To our knowledge this is the first study attempting to encode tissue planes in robotic adrenalectomy. The results show that the visual contrast distinction observed between adrenal and adjacent retroperitoneal tissues can be quantified using pixel intensity. ICG enabled the distinction of tissue planes with a wider gradient compared to conventional RGB view, quantifying its subjective benefits reported in prior studies.


Assuntos
Neoplasias das Glândulas Suprarrenais , Laparoscopia , Procedimentos Cirúrgicos Robóticos , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Neoplasias das Glândulas Suprarrenais/patologia , Neoplasias das Glândulas Suprarrenais/cirurgia , Adrenalectomia/métodos , Humanos , Verde de Indocianina , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA