Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Sep Sci ; 47(1): e2300576, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38117985

RESUMO

The level of vitamin B group in human serum is an important index of human health. Among B vitamins, cyanocobalamin in serum is unstable and its content is extremely low. Rapid and simultaneous detection of multiple B vitamins including cyanocobalamin is a challenge. Herein, we have developed a rapid and stable method that can realize the determination of thiamine, riboflavin, nicotinamide, pantothenic acid, pyridoxic acid, biotin, 5-methyltetrahydrofolate, and cyanocobalamin simultaneously in 6 min. The method was established based on protein precipitation with methanol and then chromatographic separation was achieved using Waters acquity ultra-high-performance liquid chromatography high strength silica T3 column, which was stable and sensitive especially for cyanocobalamin. Limit of quantification, precision, trueness, and matrix effect were validated according to the European Medicines Agency and United States Food and Drug guidelines and Clinical and Laboratory Standards Institute guidelines on bioanalytical method. The limit of quantification for thiamine, riboflavin, nicotinamide, pantothenic acid, pyridoxic acid, biotin, 5-methyltetrahydrofolate, and cyanocobalamin was 0.4, 0.4, 0.8, 2.0, 0.4, 0.1, 0.4, and 0.04 ng/mL separately, respectively. Intra- and interday precisions were 1.1%-12.4% and 2.0%-13.5%, respectively. The relative errors were between 0.3% and 13.3%, and the matrix effects were between 2.6% and 10.4%.


Assuntos
Complexo Vitamínico B , Humanos , Ácido Pantotênico/análise , Biotina/análise , Espectrometria de Massas em Tandem/métodos , Ácido Piridóxico , Cromatografia Líquida/métodos , Tiamina/análise , Riboflavina/análise , Niacinamida/análise , Vitamina B 12/análise , Cromatografia Líquida de Alta Pressão/métodos , Vitamina A/análise , Vitamina K/análise
2.
Wei Sheng Yan Jiu ; 53(3): 455-464, 2024 May.
Artigo em Zh | MEDLINE | ID: mdl-38839588

RESUMO

OBJECTIVE: To establish an ultra-performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS) method for simultaneous determination of 11 nutritional components(thiamine, riboflavin, nicotinamide, nicotinic acid, pantothenic acid, pyridoxine, pyridoxal, pyridoxamine, biotin, choline, L-carnitine) in liquid milk. METHODS: Milk samples were shaken with 20 mmol/L ammonium formate solution and heated in a water bath at 100 ℃ for 30 min, then incubated with papain and acid phosphatase at 45 ℃ for 16 h, the lower liquid was collected after centrifugation for analysis. UPLC separation was performed on an ACQUITY~(TM) HSS T3(3.0 mm×150 mm, 1.8 µm) column, 2 mmol/L ammonium formate(containing 0.1% formic acid) solution and acetonitrile(containing 0.1% formic acid) were used as mobile phase. Quantitative detection was performed by internal standard method. RESULTS: 11 nutritional components can be effectively separated and detected in 12 min, and the linear correlation coefficients(R~2) were all above 0.995. The limits of detection(LODs) were between 0.05 and 0.50 µg/L, and the limits of quantification(LOQs) were between 0.20 and 1.25 µg/L. The recovery rates of three-level addition were 85.6%-119.3%, and the precision RSDs were between 3.68% and 7.82%(n=6). Based on the detection of 60 liquid milk samples from 5 different animals, it was found that the contents of 11 nutrients in liquid milk from different milk sources were significantly different, but pyridoxine could not be detected. CONCLUSION: The method can quantitatively detect 11 water-soluble nutrients, including free and bound forms, by effective enzymolysis. It is sensitive, reproducible and can meet the needs of quantitative detection.


Assuntos
Leite , Espectrometria de Massas em Tandem , Leite/química , Espectrometria de Massas em Tandem/métodos , Animais , Cromatografia Líquida de Alta Pressão/métodos , Niacinamida/análise , Riboflavina/análise , Nutrientes/análise , Ácido Pantotênico/análise , Bovinos , Piridoxina/análise , Niacina/análise , Carnitina/análise
3.
Biosensors (Basel) ; 14(6)2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38920615

RESUMO

Fungal plant pathogens have posed a significant threat to crop production. However, the large-scale application of pesticides is associated with possible risks for human health and the environment. Boscalid is a widely used fungicide, consistently implemented for the management of significant plant pathogens. Conventionally, the detection and determination of boscalid residues is based on chromatographic separations. In the present study, a Bioelectric Recognition Assay (BERA)-based experimental approach combined with MIME technology was used, where changes in the electric properties of the membrane-engineering cells with anti-boscalid antibodies were recorded in response to the presence of boscalid at different concentrations based on the maximum residue level (MRL) for lettuce. The membrane-engineering Vero cells with 0.5 µg/mL of antibody in their surface were selected as the best cell line in combination with the lowest antibody concentration. Furthermore, the biosensor was tested against another fungicide in order to prove its selectivity. Finally, the BERA cell-based biosensor was able to detect the boscalid residue, below and above the MRL, in spiked lettuce leaf extracts in an entirely distinct and reproducible manner. This study indicates that the BERA-based biosensor, after further development and optimization, could be used for the routine, high-throughput detection of boscalid residue in lettuce, and not only that.


Assuntos
Técnicas Biossensoriais , Lactuca , Lactuca/química , Células Vero , Niacinamida/análise , Niacinamida/análogos & derivados , Chlorocebus aethiops , Animais , Compostos de Bifenilo , Fungicidas Industriais/análise
4.
Rev. cuba. farm ; 34(2): 93-9, mayo-ago. 2000. tab, graf
Artigo em Espanhol | LILACS | ID: lil-281154

RESUMO

Se presentan los resultados obtenidos en la validación de un método analítico por cromatografía líquida de alta resolución, para la determinación de tiamina mononitrato, piridoxina clorhidrato y nicotinamida en el suplemento nutricional neovitamin II, el cual se diseñó para separar las vitaminas entre sí, con la utilización de una columna RP-18 de 25 cm y un detector UV-Visible. Dicho método se empleó para el control de la calidad y la estabilidad de este producto. El método fue validado siguiendo una metodología de trabajo elaborada previamente en un Protocolo de Validación, donde se analizaron diferentes parámetros como son: linealidad, exactitud, precisión, selectividad, límites de detección y cuantificación, adecuación del sistema y estabilidad de las soluciones. Se obtuvieron resultados satisfactorios y se comprobó de esta forma la validez del método analítico


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Estabilidade de Medicamentos , Niacinamida/análise , Piridoxina/análise , Qualidade dos Medicamentos Homeopáticos , Suplementos Nutricionais/análise , Tiamina/análise
5.
São Paulo; s.n; 6 out. 2006. 193 p. ilus, tab, graf.
Tese em Português | LILACS | ID: lil-450144

RESUMO

A adição de vitaminas aos produtos industrializados tornou-se prática comum para as indústrias de alimentos e os teores adicionados devem obedecer à legislação brasileira durante toda a vida de prateleira dos produtos. Sabendo da sensibilidade das vitaminas a fatores como oxigênio, luz e calor, é essencial conhecer o comportamento destes compostos no alimento frente aos fatores críticos. Informações confiáveis sobre teores de vitaminas somente podem ser obtidas com métodos analíticos validados. A perspectiva deste trabalho é desenvolver metodologias analíticas por cromatografia líquida de alta eficiência para determinação de vitaminas B1, B2, B6 e PP, validá-las e então analisar amostras submetidas a diferentes condições de estocagem durante 10 meses para verificação do comportamento destas vitaminas


Assuntos
Indústria Alimentícia , Niacinamida/análise , Riboflavina/análise , Tiamina/análise , /análise , Vitaminas Hidrossolúveis/análise , Cromatografia Líquida/métodos , Armazenamento de Alimentos , Alimentos Fortificados
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA