Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 259
Filtrar
1.
Dev Biol ; 513: 50-62, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38492873

RESUMO

The voltage gated (Kv) slow-inactivating delayed rectifier channel regulates the development of hollow organs of the zebrafish. The functional channel consists of the tetramer of electrically active Kcnb1 (Kv2.1) subunits and Kcng4b (Kv6.4) modulatory or electrically silent subunits. The two mutations in zebrafish kcng4b gene - kcng4b-C1 and kcng4b-C2 (Gasanov et al., 2021) - have been studied during ear development using electrophysiology, developmental biology and in silico structural modelling. kcng4b-C1 mutation causes a C-terminal truncation characterized by mild Kcng4b loss-of-function (LOF) manifested by failure of kinocilia to extend and formation of ectopic otoliths. In contrast, the kcng4b-C2-/- mutation causes the C-terminal domain to elongate and the ectopic seventh transmembrane (TM) domain to form, converting the intracellular C-terminus to an extracellular one. Kcng4b-C2 acts as a Kcng4b gain-of-function (GOF) allele. Otoliths fail to develop and kinocilia are reduced in kcng4b-C2-/-. These results show that different mutations of the silent subunit Kcng4 can affect the activity of the Kv channel and cause a wide range of developmental defects.


Assuntos
Orelha , Canais de Ânion Dependentes de Voltagem , Proteínas de Peixe-Zebra , Peixe-Zebra , Animais , Orelha/embriologia , Mutação/genética , Peixe-Zebra/genética , Peixe-Zebra/embriologia , Proteínas de Peixe-Zebra/genética , Proteínas de Peixe-Zebra/metabolismo , Canais de Ânion Dependentes de Voltagem/genética , Canais de Ânion Dependentes de Voltagem/metabolismo
2.
Opt Lett ; 49(10): 2637-2640, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748124

RESUMO

Optical-resolution photoacoustic microscopy (OR-PAM) excels in precisely imaging a biological tissue based on absorption contrast. However, existing OR-PAMs are confined by fixed compromises between spatial resolution and field of view (FOV), preventing the integration of large FOV and local high-resolution within one system. Here, we present a non-telecentric OR-PAM (nTC-PAM) that empowers efficient adaptation of FOV and spatial resolution to match the multi-scale requirement of diverse biological imaging. Our method allows for a large-scale transformation in FOV and even surpassing the nominal FOV of the objective with minimal marginal degradation of the lateral resolution. We demonstrate the advantage of nTC-PAM through multi-scale imaging of the leaf phantom, mouse ear, and cortex. The results reveal that nTC-PAM can switch the FOV and spatial resolution to meet the requirements of different biological tissues, such as large-scale imaging of the whole cerebral cortex and high-resolution imaging of microvascular structures in local brain regions.


Assuntos
Microscopia , Técnicas Fotoacústicas , Técnicas Fotoacústicas/métodos , Animais , Camundongos , Microscopia/métodos , Orelha/diagnóstico por imagem , Orelha/irrigação sanguínea , Imagens de Fantasmas
3.
Opt Lett ; 49(11): 3054-3057, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38824326

RESUMO

Photoacoustic imaging (PAI) utilizes the photoacoustic effect to record both vascular and functional characteristics of a biological tissue. Photoacoustic signals have typically low amplitude that cannot be read efficiently by data acquisition systems. This necessitates the use of one or more amplifiers. These amplifiers are somewhat bulky (e.g., the ZFL-500LN+, Mini-Circuits, USA, or 351A-3-50-NI, Analog Modules Inc., USA). Here, we describe the fabrication and development process of a transducer with a built-in low-noise preamplifier that is encased within the transducer housing. This new, to the best of our knowledge, design could be advantageous for applications where a compact transducer + preamplifier is required. We demonstrate the performance of this compact detection unit in a laser scanning photoacoustic microscopy system by imaging a rat ear ex vivo and a rat brain vasculature in vivo.


Assuntos
Desenho de Equipamento , Técnicas Fotoacústicas , Transdutores , Técnicas Fotoacústicas/instrumentação , Técnicas Fotoacústicas/métodos , Animais , Ratos , Miniaturização , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Orelha/diagnóstico por imagem , Orelha/irrigação sanguínea , Amplificadores Eletrônicos
4.
Mol Pharm ; 21(5): 2298-2314, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38527915

RESUMO

Hypertrophic scars (HS) still remain an urgent challenge in the medical community. Traditional Chinese medicine (TCM) has unique advantages in the treatment of HS. However, due to the natural barrier of the skin, it is difficult for the natural active components of TCM to more effectively penetrate the skin and exert therapeutic effects. Therefore, the development of an efficient drug delivery system to facilitate enhanced transdermal absorption of TCM becomes imperative for its clinical application. In this study, we designed a compound Salvia miltiorrhiza-Blumea balsamifera nanoemulsion gel (CSB-NEG) and investigated its therapeutic effects on rabbit HS models. The prescription of CSB-NEG was optimized by single-factor, pseudoternary phase diagram, and central composite design experiments. The results showed that the average particle size and PDI of the optimized CSB-NE were 46.0 ± 0.2 nm and 0.222 ± 0.004, respectively, and the encapsulation efficiency of total phenolic acid was 93.37 ± 2.56%. CSB-NEG demonstrated excellent stability and skin permeation in vitro and displayed a significantly enhanced ability to inhibit scar formation compared to the CSB physical mixture in vivo. After 3 weeks of CSB-NEG treatment, the scar appeared to be flat, pink, and flexible. Furthermore, this treatment also resulted in a decrease in the levels of the collagen I/III ratio and TGF-ß1 and Smad2 proteins while simultaneously promoting the growth and remodeling of microvessels. These findings suggest that CSB-NEG has the potential to effectively address the barrier properties of the skin and provide therapeutic benefits for HS, offering a new perspective for the prevention and treatment of HS.


Assuntos
Cicatriz Hipertrófica , Emulsões , Géis , Salvia miltiorrhiza , Absorção Cutânea , Coelhos , Animais , Cicatriz Hipertrófica/tratamento farmacológico , Salvia miltiorrhiza/química , Absorção Cutânea/efeitos dos fármacos , Emulsões/química , Medicamentos de Ervas Chinesas/química , Medicamentos de Ervas Chinesas/farmacologia , Modelos Animais de Doenças , Pele/efeitos dos fármacos , Pele/patologia , Pele/metabolismo , Administração Cutânea , Tamanho da Partícula , Masculino , Nanopartículas/química , Medicina Tradicional Chinesa/métodos , Orelha/patologia , Sistemas de Liberação de Medicamentos/métodos
5.
Ear Hear ; 45(4): 884-893, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38326953

RESUMO

OBJECTIVES: This study aimed to determine whether the improvement of hearing by surgical treatment alleviates cognitive demands through pupil response in patients with unilateral congenital aural atresia (CAA). DESIGN: A prospective study was performed on patients with unilateral CAA who were scheduled to undergo primary atresioplasty between November 2017 and May 2020. Pure-tone audiometry, auditory digit span test, Korean Speech Perception in Noise test, pupil measurement during speech tests, and questionnaires (Sound-Spatial-Qualities of Hearing Scale; subjective listening effort rating) were performed before and 6 months after surgery. RESULTS: Of 30 consecutive patients who initially enrolled, only 18 patients (12 males and 6 females) were included in the analysis. When the improvement of the air-bone gap and interaural difference of air conduction within 30 dB was defined as a successful hearing outcome, successful hearing improvement was achieved in 50% of the 18 patients. In pupil measurement, the success group had a significantly smaller mean pupil dilation response than the nonsuccess group at 0 and -3 dB signal to noise ratio (SNR) (all p < 0.01). In addition, significant differences were identified between the two groups for peak dilation and peak latency at all noise levels (all p < 0.01). When analyzing the change in pupil response before and after surgery, the difference in relative mean pupil dilation in the success group was significantly greater than that in the nonsuccess group at -3 dB SNR ( p = 0.02). In addition, the success group showed a significantly greater change in peak latency than the nonsuccess group at the -3 dB SNR ( p < 0.01). The difference in peak dilation tended to be greater in the success group than in the nonsuccess group, but the difference was not statistically significant. CONCLUSIONS: Patients with unilateral CAA who achieved surgically improved hearing had a smaller pupil dilation response than those who did not. These results suggest that successful hearing outcomes after surgery in patients with unilateral CAA may reduce the cognitive effort required to understand speech under difficult listening conditions.


Assuntos
Percepção da Fala , Humanos , Feminino , Masculino , Estudos Prospectivos , Criança , Pupila/fisiologia , Audiometria de Tons Puros , Anormalidades Congênitas/cirurgia , Anormalidades Congênitas/fisiopatologia , Adolescente , Pré-Escolar , Reflexo Pupilar , Resultado do Tratamento , Orelha/anormalidades
6.
Nephrology (Carlton) ; 29(8): 541-546, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38584358

RESUMO

Townes-Brocks syndrome (TBS) is an autosomal dominant disorder characterised by the triad of anorectal, thumb, and ear malformations. It may also be accompanied by defects in kidney, heart, eyes, hearing, and feet. TBS has been demonstrated to result from heterozygous variants in the SALL1 gene, which encodes zinc finger protein believed to function as a transcriptional repressor. The clinical characteristics of an atypical TBS phenotype patient from a Chinese family are described, with predominant manifestations including external ear dysplasia, unilateral renal hypoplasia with mild renal dysfunction, and hearing impairment. A novel heterozygous variant c.3060T>A (p.Tyr1020*) in exon 2 of the SALL1 gene was identified in this proband. Pyrosequencing of the complementary DNA of the proband revealed that the variant transcript accounted for 48% of the total transcripts in peripheral leukocytes, indicating that this variant transcript has not undergone nonsense-mediated mRNA decay. This variant c.3060T > A is located at the terminal end of exon 2, proximal to the 3' end of the SALL1 gene, and exerts a relatively minor impact on protein function. We suggest that the atypical TBS phenotype observed in the proband may be attributed to the truncated protein retaining partial SALL1 function.


Assuntos
Anormalidades Múltiplas , Perda Auditiva Neurossensorial , Fatores de Transcrição , Feminino , Humanos , Masculino , Anormalidades Múltiplas/genética , Anus Imperfurado/genética , Anus Imperfurado/diagnóstico , China , Análise Mutacional de DNA , Orelha/anormalidades , População do Leste Asiático/genética , Predisposição Genética para Doença , Hereditariedade , Heterozigoto , Mutação , Linhagem , Fenótipo , Polegar/anormalidades , Fístula Traqueoesofágica/genética , Fatores de Transcrição/genética
7.
Am J Otolaryngol ; 45(5): 104430, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39059172

RESUMO

OBJECTIVES: To analyze anatomic variations of the temporal bone in congenital aural atresia (CAA) and their correlation with the Jahrsdoerfer score, in order to guide clinical selection of surgical treatment methods. MATERIAL AND METHODS: We retrospectively studied 53 patients (72 ears) with unilateral or bilateral CAA, including 34 ears with normal hearing as controls. Audiological and imaging data were collected and analyzed. We evaluated the Jahrsdoerfer score and anatomical variations, including tegmen mastoideum position, anterior sigmoid sinus displacement, and elevated jugular bulb. RESULTS: The average air conduction hearing threshold (PTA4) ranged from 0.5 to 4 kHz was 65.48 ± 8.19 dBHL, with an average Jahrsdoerfer score of 4.93 ± 2.78. In CAA group, there was a higher prevalence and severity of anterior sigmoid sinus and low position of the tegmen mastoideum (P < 0.01). However, there was no significant difference in incidence rates among groups with high jugular bulb (P > 0.05). Anterior sigmoid sinus and high jugular bulb showed no correlation with the Jahrsdoerfer score, while the low position of the tegmen mastoideum had a weak correlation. The Jahrsdoerfer score did not adequately predict temporal bone anatomical abnormalities in CAA patients. CONCLUSION: CAA exhibit a higher incidence and greater severity of temporal bone anatomical abnormalities compared to the control group, and the Jahrsdoerfer score inadequately assesses these abnormalities. Anomalies like low position of the tegmen mastoideum, anterior sigmoid sinus, and high jugular bulb should also be considered as independent factors influencing surgical decisions for atresiaplasty.


Assuntos
Orelha , Osso Temporal , Humanos , Osso Temporal/anormalidades , Osso Temporal/diagnóstico por imagem , Osso Temporal/cirurgia , Feminino , Masculino , Estudos Retrospectivos , Adolescente , Criança , Orelha/anormalidades , Orelha/cirurgia , Adulto , Anormalidades Congênitas/cirurgia , Anormalidades Congênitas/diagnóstico por imagem , Adulto Jovem , Pré-Escolar
8.
Am J Otolaryngol ; 45(2): 104175, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38113773

RESUMO

PURPOSE: To discuss the treatment of external auditory canal stenosis or atresia occurring as a complication of transcanal endoscopic ear surgery. MATERIALS AND METHODS: We retrospectively analyzed the medical records of 11 patients who developed external auditory canal stenosis or atresia after undergoing transcanal endoscopic ear surgery. The 10 patients with stenosis were treated with external auditory canal expansion via drainage tube insertion; 2 of these patients further received local injections of triamcinolone acetonide. One patient with atresia was treated with meatoplasty surgery followed by tube insertion and triamcinolone acetonide injection. RESULTS: The stenosis/atresia improved in all patients, and the external auditory canal was unobstructed without restenosis. CONCLUSIONS: Stenosis/atresia of the external auditory canal after transcanal endoscopic ear surgery should be treated with dilation therapy/meatoplasty in a timely manner to prevent progressive hyperplasia of the scar and regain a normal-sized ear canal.


Assuntos
Meato Acústico Externo , Triancinolona Acetonida , Humanos , Meato Acústico Externo/cirurgia , Estudos Retrospectivos , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Orelha
9.
Am J Otolaryngol ; 45(1): 104050, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37741025

RESUMO

BACKGROUND: Cochlear implantation (CI) in children with malformed ears can be challenging through the standard surgical technique. Several alternative approaches have been described. The endoscopic-assisted approach can be chosen as an effective and safe surgical technique, overcoming the drawbacks of the traditional approach. MATERIAL: We further describe a combined technique based on a limited mastoidectomy with no posterior tympanotomy and an endoscopic transmeatal approach to the round window (RW): the electrode is driven from the mastoid to the middle ear through the attic. RESULTS: The concomitant endoscopic assistance allows for improved surgical vision, reducing the risk of major complications. The main advantages of this technique are related to better visualization of the RW for safe insertion of the electrode; avoidance of damage to the facial nerve (FN), due to direct visualization, and sparing the posterior tympanotomy; avoidance of subtotal petrosectomy, if not necessary. CONCLUSION: The purpose of this article, supported with a video file, is to describe step by step this endoscopic-assisted procedure in a patient with middle ear malformation.


Assuntos
Implante Coclear , Implantes Cocleares , Criança , Humanos , Implante Coclear/métodos , Orelha/cirurgia , Orelha Média/cirurgia , Audição , Janela da Cóclea/cirurgia
10.
Eur Arch Otorhinolaryngol ; 281(6): 2849-2859, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38647685

RESUMO

PURPOSE: The indications of Vibrant Soundbridge (VSB) have been expanded to include patients with conductive and mixed hearing loss due to congenital aural atresia (CAA). However, the current evidence supporting the auditory outcomes of VSB is based mainly on case reports and retrospective chart reviews. Therefore, the present systematic review aims to summarize and critically appraise the current evidence regarding the safety and effectiveness of VSB in children and adult patients with CAA. METHODS: A systematic literature search retrieved studies that evaluated the outcomes of unilateral or bilateral implantation of VSB in patients with CAA. The bibliographic search was conducted in PubMed, Scopus, EBSCO, and Cochrane Central Register of Controlled Trials (CENTRAL) databases from January 2000 to December 2022. RESULTS: Twenty-seven studies were included in the present systematic review. Overall, the speech perception after VSB was good, with a mean word recognition score (WRS) score ranging from 60 to 96.7%. The mean postoperative speech recognition threshold (SRT) after implantation ranged from 20.8 to 50 dB. The effective gain was reported in 15 studies, ranging from 31.3 to 45.5 dB. In terms of user satisfaction with VSB, the included studies showed significant improvements in the patient-reported outcomes, such as the Speech Spatial and Qualities of Hearing scale and Glasgow Hearing Aid Benefit Profile. The VSB implantation was generally safe with low incidence of postoperative complications. CONCLUSION: VSB provides significant benefits to individuals with hearing loss owing to CAA, with very good subjective outcomes and a low risk of complications.


Assuntos
Anormalidades Congênitas , Orelha , Humanos , Anormalidades Congênitas/cirurgia , Orelha/anormalidades , Orelha/cirurgia , Auxiliares de Audição , Perda Auditiva Condutiva/cirurgia , Perda Auditiva Condutiva/congênito , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Percepção da Fala
11.
Sensors (Basel) ; 24(4)2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38400384

RESUMO

EEG-enabled earbuds represent a promising frontier in brain activity monitoring beyond traditional laboratory testing. Their discrete form factor and proximity to the brain make them the ideal candidate for the first generation of discrete non-invasive brain-computer interfaces (BCIs). However, this new technology will require comprehensive characterization before we see widespread consumer and health-related usage. To address this need, we developed a validation toolkit that aims to facilitate and expand the assessment of ear-EEG devices. The first component of this toolkit is a desktop application ("EaR-P Lab") that controls several EEG validation paradigms. This application uses the Lab Streaming Layer (LSL) protocol, making it compatible with most current EEG systems. The second element of the toolkit introduces an adaptation of the phantom evaluation concept to the domain of ear-EEGs. Specifically, it utilizes 3D scans of the test subjects' ears to simulate typical EEG activity around and inside the ear, allowing for controlled assessment of different ear-EEG form factors and sensor configurations. Each of the EEG paradigms were validated using wet-electrode ear-EEG recordings and benchmarked against scalp-EEG measurements. The ear-EEG phantom was successful in acquiring performance metrics for hardware characterization, revealing differences in performance based on electrode location. This information was leveraged to optimize the electrode reference configuration, resulting in increased auditory steady-state response (ASSR) power. Through this work, an ear-EEG evaluation toolkit is made available with the intention to facilitate the systematic assessment of novel ear-EEG devices from hardware to neural signal acquisition.


Assuntos
Interfaces Cérebro-Computador , Dispositivos Eletrônicos Vestíveis , Humanos , Orelha , Encéfalo/fisiologia , Eletroencefalografia/métodos , Eletrodos
12.
Sensors (Basel) ; 24(9)2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38732771

RESUMO

Human activity recognition (HAR) technology enables continuous behavior monitoring, which is particularly valuable in healthcare. This study investigates the viability of using an ear-worn motion sensor for classifying daily activities, including lying, sitting/standing, walking, ascending stairs, descending stairs, and running. Fifty healthy participants (between 20 and 47 years old) engaged in these activities while under monitoring. Various machine learning algorithms, ranging from interpretable shallow models to state-of-the-art deep learning approaches designed for HAR (i.e., DeepConvLSTM and ConvTransformer), were employed for classification. The results demonstrate the ear sensor's efficacy, with deep learning models achieving a 98% accuracy rate of classification. The obtained classification models are agnostic regarding which ear the sensor is worn and robust against moderate variations in sensor orientation (e.g., due to differences in auricle anatomy), meaning no initial calibration of the sensor orientation is required. The study underscores the ear's efficacy as a suitable site for monitoring human daily activity and suggests its potential for combining HAR with in-ear vital sign monitoring. This approach offers a practical method for comprehensive health monitoring by integrating sensors in a single anatomical location. This integration facilitates individualized health assessments, with potential applications in tele-monitoring, personalized health insights, and optimizing athletic training regimes.


Assuntos
Dispositivos Eletrônicos Vestíveis , Humanos , Adulto , Masculino , Feminino , Pessoa de Meia-Idade , Adulto Jovem , Atividades Humanas , Orelha/fisiologia , Algoritmos , Atividades Cotidianas , Aprendizado de Máquina , Aprendizado Profundo , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Movimento (Física) , Caminhada/fisiologia
13.
BMC Oral Health ; 24(1): 803, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39014351

RESUMO

BACKGROUND: Auriculocondylar syndrome (ARCND) is an extremely rare autosomal dominant or recessive condition that typically manifests as question mark ears (QMEs), mandibular condyle hypoplasia, and micrognathia. Severe dental and maxillofacial malformations present considerable challenges in patients' lives and clinical treatment. Currently, only a few ARCND cases have been reported worldwide, but most of them are related to genetic mutations, clinical symptoms, and ear correction; there are few reports concerning the treatment of dentofacial deformities. CASE PRESENTATION: Here, we report a rare case of ARCND in a Chinese family. A novel insertional mutation in the guanine nucleotide-binding protein alpha-inhibiting activity polypeptide 3 (GNAI3) was identified in the patient and their brother using whole-exome sequencing. After a multidisciplinary consultation and examination, sequential orthodontic treatment and craniofacial surgery, including distraction osteogenesis and orthognathic surgery, were performed using three-dimensional (3D) digital technology to treat the patient's dentofacial deformity. A good prognosis was achieved at the 5-year follow-up, and the patient returned to normal life. CONCLUSIONS: ARCND is a monogenic and rare condition that can be diagnosed based on its clinical triad of core features. Molecular diagnosis plays a crucial role in the diagnosis of patients with inconspicuous clinical features. We present a novel insertion variation in GNAI3, which was identified in exon 2 of chromosome 110116384 in a Chinese family. Sequential therapy with preoperative orthodontic treatment combined with distraction osteogenesis and orthognathic surgery guided by 3D digital technology may be a practical and effective method for treating ARCND.


Assuntos
Deformidades Dentofaciais , Humanos , Masculino , Deformidades Dentofaciais/genética , Deformidades Dentofaciais/cirurgia , Seguimentos , Otopatias/genética , Otopatias/cirurgia , Subunidades alfa Gi-Go de Proteínas de Ligação ao GTP/genética , Linhagem , Orelha/anormalidades , Osteogênese por Distração/métodos , Mutação , Procedimentos Cirúrgicos Ortognáticos , China , População do Leste Asiático
16.
Trends Hear ; 28: 23312165231215916, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38284359

RESUMO

When presenting two competing speech stimuli, one to each ear, a right-ear advantage (REA) can often be observed, reflected in better speech recognition compared to the left ear. Considering the left-hemispheric dominance for language, the REA has been explained by superior contralateral pathways (structural models) and language-induced shifts of attention to the right (attentional models). There is some evidence that the REA becomes more pronounced, as cognitive load increases. Hence, it is interesting to investigate the REA in static (constant target talker) and dynamic (target changing pseudo-randomly) cocktail-party situations, as the latter is associated with a higher cognitive load than the former. Furthermore, previous research suggests an increasing REA, when listening becomes more perceptually challenging. The present study examined the REA by using virtual acoustics to simulate static and dynamic cocktail-party situations, with three spatially separated talkers uttering concurrent matrix sentences. Sentences were presented at low sound pressure levels or processed with a noise vocoder to increase perceptual load. Sixteen young normal-hearing adults participated in the study. The REA was assessed by means of word recognition scores and a detailed error analysis. Word recognition revealed a greater REA for the dynamic than for the static situations, compatible with the view that an increase in cognitive load results in a heightened REA. Also, the REA depended on the type of perceptual load, as indicated by a higher REA associated with vocoded compared to low-level stimuli. The results of the error analysis support both structural and attentional models of the REA.


Assuntos
Percepção da Fala , Adulto , Humanos , Estimulação Acústica , Orelha , Ruído
17.
Med Eng Phys ; 129: 104192, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38906574

RESUMO

Poor utilization of earplugs among military personnel may be due to discomfort caused by the occlusion effect (OE). The OE occurs when an earplug occludes the ear canal, thereby changing bone conduction (BC) hearing and amplifying physiological noises from the wearer. There is a need to understand and reduce the OE in the human ear. A 3D finite element model of the human ear including a 3-chambered spiral cochlea was employed to simulate the OE caused by foam and aerogel earplugs. 90 dB sound pressure was applied at the ear canal entrance and BC sound was applied as vibration of the canal bony wall. The model reported the ear canal pressure and the displacements of the stapes footplate and cochlear basilar membrane with and without earplugs. Without BC stimulation, the foam earplug showed a greater pressure attenuation than the aerogel earplug. However, the foam earplug results were more affected by BC stimulation, with a maximum sound pressure increase of 34 dB, compared to the 21.0 dB increase with the aerogel earplug. The aerogel earplug's lower OE demonstrates its promise as an earplug material. Future work with this model will examine BC sound transmission in the cochlea.


Assuntos
Análise de Elementos Finitos , Pressão , Humanos , Dispositivos de Proteção das Orelhas , Orelha , Condução Óssea , Modelos Biológicos
18.
Mol Genet Genomic Med ; 12(4): e2441, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38618928

RESUMO

BACKGROUND: Auriculocondylar syndrome (ARCND) is a rare congenital craniofacial developmental malformation syndrome of the first and second pharyngeal arches with external ear malformation at the junction between the lobe and helix, micromaxillary malformation, and mandibular condylar hypoplasia. Four subtypes of ARCND have been described so far, that is, ARCND1 (OMIM # 602483), ARCND2 (ARCND2A, OMIM # 614669; ARCND2B, OMIM # 620458), ARCND3 (OMIM # 615706), and ARCND4 (OMIM # 620457). METHODS: This study reports a case of ARCND2 resulting from a novel pathogenic variant in the PLCB4 gene, and summarizes PLCB4 gene mutation sites and phenotypes of ARCND2. RESULTS: The proband, a 5-day-old male neonate, was referred to our hospital for respiratory distress. Micrognathia, microstomia, distinctive question mark ears, as well as mandibular condyle hypoplasia were identified. Trio-based whole-exome sequencing identified a novel missense variant of NM_001377142.1:c.1928C>T (NP_001364071.1:p.Ser643Phe) in the PLCB4 gene, which was predicted to impair the local structural stability with a result that the protein function might be affected. From a review of the literature, only 36 patients with PLCB4 gene mutations were retrieved. CONCLUSION: As with other studies examining familial cases of ARCND2, incomplete penetrance and variable expressivity were observed within different families' heterozygous mutations in PLCB4 gene. Although, motor and intellectual development are in the normal range in the vast majority of patients with ARCND2, long-term follow-up and assessment are still required.


Assuntos
Otopatias , Orelha , Micrognatismo , Humanos , Recém-Nascido , Masculino , China , Orelha/anormalidades , Fosfolipase C beta , População do Leste Asiático
19.
Otol Neurotol ; 45(1): 1-10, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38085758

RESUMO

OBJECTIVE: To compare audiometric outcomes, complications, and revisions required for percutaneous (pBCD) versus transcutaneous (tBCD) implantable bone-conduction devices for the treatment of hearing loss associated with congenital aural atresia (CAA).Databases Reviewed.PubMed, Scopus, CINAHL. METHODS: A systematic review was performed searching for English language articles from inception to December 14, 2022. Studies reporting audiometric outcomes or complications for either pBCDs or tBCDs for the treatment of CAA were selected for inclusion. A meta-analysis of single means and meta-analysis of proportions with comparison (Δ) of weighted proportions was conducted. RESULTS: A total of 56 articles with 756 patients were selected for inclusion. One hundred ninety patients were implanted with pBCDs, whereas the remaining 566 were implanted with tBCDs. Mean pure-tone audiometry improvement in the pBCD group (39.1 ± 1.1 dB) was significantly higher than in the tBCD group (34.6 ± 1.6 dB; Δ4.5 dB; 95% confidence interval, 4.2-4.7 dB; p < 0.0001). The average improvement in speech reception threshold was 38.6 ± 2.5 dB in the percutaneous group as compared with 32.7 ± 1.6 dB in the transcutaneous group (Δ5.9 dB [5.3-6.5 dB], p < 0.0001). Overall complication rates for patients implanted with pBCDs and tBCDs were 29.0% (15.7-44.4%) and 9.4% (6.5%-13.0%), respectively (Δ19.6% [12.0-27.7%], p < 0.0001). CONCLUSIONS: Patients with CAA implanted with pBCDs had significantly better audiometric outcomes than those implanted with tBCDs. However, complication rates were significantly higher among the pBCD group.


Assuntos
Orelha , Auxiliares de Audição , Humanos , Resultado do Tratamento , Orelha/anormalidades , Audição , Audiometria de Tons Puros , Estudos Retrospectivos , Condução Óssea , Perda Auditiva Condutiva
20.
Sci Rep ; 14(1): 1418, 2024 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-38228747

RESUMO

FLASH-radiotherapy may provide significant sparing of healthy tissue through ultra-high dose rates in protons, electrons, and x-rays while maintaining the tumor control. Key factors for the FLASH effect might be oxygen depletion, the immune system, and the irradiated blood volume, but none could be fully confirmed yet. Therefore, further investigations are necessary. We investigated the protective (tissue sparing) effect of FLASH in proton treatment using an in-vivo mouse ear model. The right ears of Balb/c mice were irradiated with 20 MeV protons at the ion microprobe SNAKE in Garching near Munich by using three dose rates (Conv = 0.06 Gy/s, Flash9 = 9.3 Gy/s and Flash930 = 930 Gy/s) at a total dose of 23 Gy or 33 Gy. The ear thickness, desquamation, and erythema combined in an inflammation score were measured for 180 days. The cytokines TGF-ß1, TNF-α, IL1α, and IL1ß were analyzed in the blood sampled in the first 4 weeks and at termination day. No differences in inflammation reactions were visible in the 23 Gy group for the different dose rates. In the 33 Gy group, the ear swelling and the inflammation score for Flash9 was reduced by (57 ± 12) % and (67 ± 17) % and for Flash930 by (40 ± 13) % and (50 ± 17) % compared to the Conv dose rate. No changes in the cytokines in the blood could be measured. However, an estimation of the irradiated blood volume demonstrates, that 100-times more blood is irradiated when using Conv compared to using Flash9 or Flash930. This indicates that blood might play a role in the underlying mechanisms in the protective effect of FLASH.


Assuntos
Neoplasias , Prótons , Animais , Camundongos , Orelha , Inflamação , Citocinas , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA