Your browser doesn't support javascript.
loading
Experimental investigation of the acoustic nonlinearity parameter tomography for excised pathological biological tissues.
Zhang, D; Gong, X F.
Afiliação
  • Zhang D; Institute of Acoustics, State Key Lab of Modern Acoustics, Nanjing University, China. dzhang@netra.nju.edu.cn
Ultrasound Med Biol ; 25(4): 593-9, 1999 May.
Article em En | MEDLINE | ID: mdl-10386735
ABSTRACT
The acoustic nonlinearity parameter B/A tomography is proposed as a novel imaging method in this paper. By using this method, the B/A tomography for various kinds of normal and pathological porcine tissues in vitro, including eight kinds of diseased livers, four kinds of diseased kidney and one kind of diseased spleen, are studied. Results indicate that all diseased tissues with changes in tissue composition and structural features exhibit higher grey-scale (higher B/A values) than corresponding normal tissues. In addition, the acoustic nonlinearity parameter is more sensitive to pathological states than acoustic linear parameters. To make a comparison with the acoustic nonlinearity parameter tomography, the acoustic linear parameter images, including two B-scan images for two kinds of diseased specimens, are also presented. Results of this paper show that the acoustic nonlinearity parameter tomography may be a novel method for tissue characterization in ultrasonic medical diagnosis.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Vísceras / Ultrassonografia Idioma: En Ano de publicação: 1999 Tipo de documento: Article País de afiliação: China
Buscar no Google
Base de dados: MEDLINE Assunto principal: Vísceras / Ultrassonografia Idioma: En Ano de publicação: 1999 Tipo de documento: Article País de afiliação: China