Room temperature measurement of the anisotropic loss tangent of sapphire using the whispering gallery mode technique.
Hartnett, John G; Tobar, Michael E; Ivanov, Eugene N; Krupka, Jerzy.
Afiliação
  • Hartnett JG; Frequency Standards & Metrology Group, School of Physics, University of Western Australia, 35 Stirling Hwy, Crawley WA 6009, Australia. john@physics.uwa.edu.au
Article em En | MEDLINE | ID: mdl-16471430
ABSTRACT
The anisotropic loss tangent has been determined in monocrystalline sapphire for components parallel and perpendicular to the crystal axis, using the whispering gallery (WG) mode method. The Q-factors of quasi-TE and quasi-TM modes were measured precisely in four cylindrical sapphire resonators at room temperature, from which was determined a maximum attainable Q-factor of (2.1 +/- 0.2) x 10(5) at 9 GHz in a quasi-TM mode. Sapphire dielectric material from three different manufacturers was compared over the 270-345 K temperature range and the 5-16 GHz frequency range.