[Three-dimensional finite element analysis of three conjunctive methods of free iliac bone graft for established mandibular body defects].
Hua Xi Kou Qiang Yi Xue Za Zhi
; 25(4): 345-8, 2007 Aug.
Article
em Zh
| MEDLINE
| ID: mdl-17896488
OBJECTIVE: To analyze the stress and displacement distribution of 3D-FE models in three conjunctive methods of vascularized iliac bone graft for established mandibular body defects. METHODS: Using computer image process technique, a series of spiral CT images were put into Ansys preprocess programe to establish three 3D-FE models of different conjunctions. RESULTS: The three 3D-FE models of established mandibular body defects by vascularized iliac bone graft were built up. The distribution of Von Mises stress and displacement around mandibular segment, grafted ilium, plates and screws was obtained. CONCLUSION: It may be determined successfully that the optimal conjunctive shape be the on-lay conjunction.
Buscar no Google
Base de dados:
MEDLINE
Assunto principal:
Análise de Elementos Finitos
/
Imageamento Tridimensional
Idioma:
Zh
Ano de publicação:
2007
Tipo de documento:
Article
País de afiliação:
China