Your browser doesn't support javascript.
loading
Fast measurement of the quadriceps femoris muscle transverse relaxation time at high magnetic field using segmented echo-planar imaging.
Fouré, Alexandre; Duhamel, Guillaume; Vilmen, Christophe; Bendahan, David; Jubeau, Marc; Gondin, Julien.
Afiliação
  • Fouré A; Aix-Marseille Université, CNRS, CRMBM UMR, 7339, Marseille, France.
  • Duhamel G; Aix-Marseille Université, CNRS, CRMBM UMR, 7339, Marseille, France.
  • Vilmen C; Aix-Marseille Université, CNRS, CRMBM UMR, 7339, Marseille, France.
  • Bendahan D; Aix-Marseille Université, CNRS, CRMBM UMR, 7339, Marseille, France.
  • Jubeau M; Aix-Marseille Université, CNRS, CRMBM UMR, 7339, Marseille, France.
  • Gondin J; Université de Nantes, Laboratoire "Motricité, Interactions, Performance,", Nantes, France.
J Magn Reson Imaging ; 45(2): 356-368, 2017 02.
Article em En | MEDLINE | ID: mdl-27381383
ABSTRACT

PURPOSE:

To assess and validate a technique for transverse relaxation time (T2 ) measurements of resting and recovering skeletal muscle following exercise with a high temporal resolution and large volume coverage using segmented spin-echo echo-planar imaging (sSE-EPI). MATERIALS AND

METHODS:

Experiments were performed on a 3T magnetic resonance imaging (MRI) scanner using a multislice sSE-EPI technique applied at different echo times (TEs). T2 measurements were first validated in vitro in calibrated T2 phantoms (range 25-152 ms) by comparing sSE-EPI, standard spin-echo (SE), and multislice multiecho (MSME) techniques (using a fitting procedure or a 2-TEs calculation). In vivo measurements of resting T2 quadriceps femoris (QF) muscle were performed with both sSE-EPI and MSME sequences. Finally, sSE-EPI was used to quantify T2 changes in recovering muscle after an exercise.

RESULTS:

T2 values measured in vitro with sSE-EPI were similar to those assessed with SE (P > 0.05). In vitro and in vivo T2 measurements obtained with sSE-EPI were independent of the T2 determination procedure (P > 0.05). In contrast, both in vitro and in vivo T2 values derived from MSME were significantly different when using 2-TEs calculation as compared to the fitting procedure (P < 0.05). sSE-EPI allowed the detection of increased T2 values in the QF muscle immediately after exercise (+14 ± 9%), while lower T2 values were recorded less than 2 min afterwards (P < 0.05).

CONCLUSION:

sSE-EPI sequence is a relevant method to monitor exercise-induced T2 changes of skeletal muscles over large volume coverage and to detect abnormal patterns of muscle activation. LEVEL OF EVIDENCE 1 J. Magn. Reson. Imaging 2017;45356-368.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Assistida por Computador / Exercício Físico / Imagem Ecoplanar / Recuperação de Função Fisiológica / Músculo Quadríceps / Contração Muscular Idioma: En Ano de publicação: 2017 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Assistida por Computador / Exercício Físico / Imagem Ecoplanar / Recuperação de Função Fisiológica / Músculo Quadríceps / Contração Muscular Idioma: En Ano de publicação: 2017 Tipo de documento: Article País de afiliação: França