BACKGROUND: Expiratory pressure relief continuous positive airway pressure (pressure relief CPAP; C-Flex™) causes increases in inspiratory duty cycle and shortening of expiratory time. It has been suggested that these changes are caused by an increase in work of breathing. OBJECTIVES: We studied the effects of C-Flex on work of breathing and intrinsic positive end-expiratory pressure as compared to fixed CPAP. METHODS: Work of breathing was analyzed in 24 patients with obstructive sleep apnea during treatment with fixed CPAP and C-Flex with 3 different pressure relief settings in a randomized order during rapid-eye-movement (REM) and non-REM sleep. Work of breathing was assessed on a breath-by-breath basis using a piezoelectric esophageal pressure catheter and a pneumotachograph for measuring airflow. RESULTS: We found there was no increase in inspiratory work of breathing observed using C-Flex compared to fixed CPAP. Instead, we found a linear decrease in inspiratory work of breathing with increasing pressure relief, with a mean difference of 1.22 J/min between CPAP and maximum pressure release (C-Flex 3; 90% of the value with nasal CPAP); however, the decrease was not statistically significant. The decrease in inspiratory work of breathing associated with C-Flex has a significant inverse correlation with BMI. CONCLUSIONS: The C-Flex technology does not change work of breathing but shows a tendency towards a reduction of inspiratory work of breathing in patients with a lower BMI using higher C-Flex. The effect is probably caused by diminishing airway resistance generated by the positive end-expiratory pressure. Our findings may lead to additional fields of application of the C-Flex technology, such as chronic obstructive pulmonary disease or muscular dystrophy.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Mecânica Respiratória / Resistência das Vias Respiratórias / Apneia Obstrutiva do Sono / Pressão Positiva Contínua nas Vias Aéreas Idioma: En Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Alemanha
Buscar no Google
Base de dados: MEDLINE Assunto principal: Mecânica Respiratória / Resistência das Vias Respiratórias / Apneia Obstrutiva do Sono / Pressão Positiva Contínua nas Vias Aéreas Idioma: En Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Alemanha