Your browser doesn't support javascript.
loading
Real-time fluorescence assay of alkaline phosphatase in living cells using boron-doped graphene quantum dots as fluorophores.
Chen, Li; Yang, Guancao; Wu, Ping; Cai, Chenxin.
Afiliação
  • Chen L; Jiangsu Key Laboratory of New Power Batteries, Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, National and Local Joint Engineering Research Center of Biomedical Functional Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210097, P
  • Yang G; Jiangsu Key Laboratory of New Power Batteries, Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, National and Local Joint Engineering Research Center of Biomedical Functional Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210097, P
  • Wu P; Jiangsu Key Laboratory of New Power Batteries, Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, National and Local Joint Engineering Research Center of Biomedical Functional Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210097, P
  • Cai C; Jiangsu Key Laboratory of New Power Batteries, Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, National and Local Joint Engineering Research Center of Biomedical Functional Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210097, P
Biosens Bioelectron ; 96: 294-299, 2017 Oct 15.
Article em En | MEDLINE | ID: mdl-28511112
ABSTRACT
This work reports a convenient and real-time assay of alkaline phosphatase (ALP) in living cells based on a fluorescence quench-recovery process at a physiological pH using the boron-doped graphene quantum dots (BGQDs) as fluorophore. The fluorescence of BGQDs is found to be effectively quenched by Ce3+ ions because of the coordination of Ce3+ ions with the carboxyl group of BGQDs. Upon addition of adenosine triphosphate (ATP) into the system, the quenched fluorescence can be recovered by the ALP-positive expressed cells (such as MCF-7 cells) due to the removal of Ce3+ ions from BGQDs surface by phosphate ions, which are generated from ATP under catalytic hydrolysis of ALP that expressed in cells. The extent of fluorescence signal recovery depends on the level of ALP in cells, which establishes the basis of ALP assay in living cells. This approach can also be used for specific discrimination of the ALP expression levels in different type of cells and thus sensitive detection of those ALP-positive expressed cells (for example MCF-7 cells) at a very low abundance (10±5 cells mL-1). The advantages of this approach are that it has high sensitivity because of the significant suppression of the background due to the Ce3+ ion quenching the fluorescence of BGQDs, and has the ability of avoiding false signals arising from the nonspecific adsorption of non-target proteins because it operates via a fluorescence quench-recovery process. In addition, it can be extended to other enzyme systems, such as ATP-related kinases.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Boro / Cério / Pontos Quânticos / Fosfatase Alcalina / Ensaios Enzimáticos / Corantes Fluorescentes / Grafite Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Boro / Cério / Pontos Quânticos / Fosfatase Alcalina / Ensaios Enzimáticos / Corantes Fluorescentes / Grafite Idioma: En Ano de publicação: 2017 Tipo de documento: Article