Your browser doesn't support javascript.
loading
Iodixanol versus Iopromide at Coronary CT Angiography: Lumen Opacification and Effect on Heart Rhythm-the Randomized IsoCOR Trial.
Lubbers, Marisa M; Kock, Marc; Niezen, André; Galema, Tjebbe; Kofflard, Marcel; Bruning, Tobias; Kooij, Henriette S; van Valen, Hanneke; Dijkshoorn, Marcel; Booij, Ronald; Padmos, Anthony; Vogels, Alain; Budde, Ricardo P J; Nieman, Koen.
Afiliação
  • Lubbers MM; From the Departments of Cardiology (M.M.L., T.G., K.N.) and Radiology (M.M.L., M.D., R.B., A.P., A.V., R.P.J.B., K.N.), Erasmus Medical Center, 's-Gravendijkwal 230, Room Ca-207a, Rotterdam 3015 CE, the Netherlands; Departments of Radiology (M. Kock, S.K.) and Cardiology (M. Kofflard), Albert Schwei
  • Kock M; From the Departments of Cardiology (M.M.L., T.G., K.N.) and Radiology (M.M.L., M.D., R.B., A.P., A.V., R.P.J.B., K.N.), Erasmus Medical Center, 's-Gravendijkwal 230, Room Ca-207a, Rotterdam 3015 CE, the Netherlands; Departments of Radiology (M. Kock, S.K.) and Cardiology (M. Kofflard), Albert Schwei
  • Niezen A; From the Departments of Cardiology (M.M.L., T.G., K.N.) and Radiology (M.M.L., M.D., R.B., A.P., A.V., R.P.J.B., K.N.), Erasmus Medical Center, 's-Gravendijkwal 230, Room Ca-207a, Rotterdam 3015 CE, the Netherlands; Departments of Radiology (M. Kock, S.K.) and Cardiology (M. Kofflard), Albert Schwei
  • Galema T; From the Departments of Cardiology (M.M.L., T.G., K.N.) and Radiology (M.M.L., M.D., R.B., A.P., A.V., R.P.J.B., K.N.), Erasmus Medical Center, 's-Gravendijkwal 230, Room Ca-207a, Rotterdam 3015 CE, the Netherlands; Departments of Radiology (M. Kock, S.K.) and Cardiology (M. Kofflard), Albert Schwei
  • Kofflard M; From the Departments of Cardiology (M.M.L., T.G., K.N.) and Radiology (M.M.L., M.D., R.B., A.P., A.V., R.P.J.B., K.N.), Erasmus Medical Center, 's-Gravendijkwal 230, Room Ca-207a, Rotterdam 3015 CE, the Netherlands; Departments of Radiology (M. Kock, S.K.) and Cardiology (M. Kofflard), Albert Schwei
  • Bruning T; From the Departments of Cardiology (M.M.L., T.G., K.N.) and Radiology (M.M.L., M.D., R.B., A.P., A.V., R.P.J.B., K.N.), Erasmus Medical Center, 's-Gravendijkwal 230, Room Ca-207a, Rotterdam 3015 CE, the Netherlands; Departments of Radiology (M. Kock, S.K.) and Cardiology (M. Kofflard), Albert Schwei
  • Kooij HS; From the Departments of Cardiology (M.M.L., T.G., K.N.) and Radiology (M.M.L., M.D., R.B., A.P., A.V., R.P.J.B., K.N.), Erasmus Medical Center, 's-Gravendijkwal 230, Room Ca-207a, Rotterdam 3015 CE, the Netherlands; Departments of Radiology (M. Kock, S.K.) and Cardiology (M. Kofflard), Albert Schwei
  • van Valen H; From the Departments of Cardiology (M.M.L., T.G., K.N.) and Radiology (M.M.L., M.D., R.B., A.P., A.V., R.P.J.B., K.N.), Erasmus Medical Center, 's-Gravendijkwal 230, Room Ca-207a, Rotterdam 3015 CE, the Netherlands; Departments of Radiology (M. Kock, S.K.) and Cardiology (M. Kofflard), Albert Schwei
  • Dijkshoorn M; From the Departments of Cardiology (M.M.L., T.G., K.N.) and Radiology (M.M.L., M.D., R.B., A.P., A.V., R.P.J.B., K.N.), Erasmus Medical Center, 's-Gravendijkwal 230, Room Ca-207a, Rotterdam 3015 CE, the Netherlands; Departments of Radiology (M. Kock, S.K.) and Cardiology (M. Kofflard), Albert Schwei
  • Booij R; From the Departments of Cardiology (M.M.L., T.G., K.N.) and Radiology (M.M.L., M.D., R.B., A.P., A.V., R.P.J.B., K.N.), Erasmus Medical Center, 's-Gravendijkwal 230, Room Ca-207a, Rotterdam 3015 CE, the Netherlands; Departments of Radiology (M. Kock, S.K.) and Cardiology (M. Kofflard), Albert Schwei
  • Padmos A; From the Departments of Cardiology (M.M.L., T.G., K.N.) and Radiology (M.M.L., M.D., R.B., A.P., A.V., R.P.J.B., K.N.), Erasmus Medical Center, 's-Gravendijkwal 230, Room Ca-207a, Rotterdam 3015 CE, the Netherlands; Departments of Radiology (M. Kock, S.K.) and Cardiology (M. Kofflard), Albert Schwei
  • Vogels A; From the Departments of Cardiology (M.M.L., T.G., K.N.) and Radiology (M.M.L., M.D., R.B., A.P., A.V., R.P.J.B., K.N.), Erasmus Medical Center, 's-Gravendijkwal 230, Room Ca-207a, Rotterdam 3015 CE, the Netherlands; Departments of Radiology (M. Kock, S.K.) and Cardiology (M. Kofflard), Albert Schwei
  • Budde RPJ; From the Departments of Cardiology (M.M.L., T.G., K.N.) and Radiology (M.M.L., M.D., R.B., A.P., A.V., R.P.J.B., K.N.), Erasmus Medical Center, 's-Gravendijkwal 230, Room Ca-207a, Rotterdam 3015 CE, the Netherlands; Departments of Radiology (M. Kock, S.K.) and Cardiology (M. Kofflard), Albert Schwei
  • Nieman K; From the Departments of Cardiology (M.M.L., T.G., K.N.) and Radiology (M.M.L., M.D., R.B., A.P., A.V., R.P.J.B., K.N.), Erasmus Medical Center, 's-Gravendijkwal 230, Room Ca-207a, Rotterdam 3015 CE, the Netherlands; Departments of Radiology (M. Kock, S.K.) and Cardiology (M. Kofflard), Albert Schwei
Radiology ; 286(1): 71-80, 2018 01.
Article em En | MEDLINE | ID: mdl-28809582
ABSTRACT
Purpose To show that equal coronary lumen opacification can be achieved with iso- and low-osmolar contrast media when it is injected at the same iodine delivery rate with contemporary cardiac computed tomographic (CT) protocols and to investigate the cardiovascular effect of iso-osmolar contrast media and the image quality achieved. Materials and Methods Institutional review board approval and written informed consent were obtained for the Effect of Iso-osmolar Contrast Medium on Coronary Opacification and Heart Rhythm in Coronary CT Angiography, or IsoCOR, trial. Between November 2015 and August 2016, 306 patients (167 [55%] women) at least 18 years old (weight range, 50-125 kg), were prospectively randomized to receive iso-osmolar iodixanol 270 or low-osmolar iopromide 300 contrast media. All coronary segments were assessed for intraluminal opacification and image quality and were compared by using the Student t test. Heart rate, arrhythmia, patient discomfort, and adverse events also were monitored. Results Mean measured coronary attenuation values ± standard deviation were comparable between the iodixanol 270 and iopromide 300 contrast media groups (469 HU ± 167 vs 447 HU ± 166, respectively [P = .241]; 95% confidence interval -15.1, 60.0), including those from subanalyses. Adjusted for the lower iodine concentration, the mean iodixanol 270 bolus was larger compared with that of iopromide 300 (76.8 mL ± 11.6 vs 69.7 mL ± 10.8, respectively; P < .001). The higher injection rate was associated with higher pressure (777 kPa ± 308 vs 630 kPa ± 252, respectively; P < .001). Although in the iodixanol 270 group patients experienced less heat discomfort (72% vs 86%, respectively; P < .001), no differences in heart rate or rhythm were observed. Conclusion If injected at comparable iodine delivery rates, the iso-osmolar contrast medium iodixanol 270 is not inferior to low-osmolar contrast medium iopromide 300 for assessment of coronary opacification. Iodixanol 270 was associated with less heat discomfort, but did not affect heart rate differently compared with iopromide 300. © RSNA, 2017 Online supplemental material is available for this article.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ácidos Tri-Iodobenzoicos / Iohexol / Angiografia Coronária / Meios de Contraste / Angiografia por Tomografia Computadorizada Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ácidos Tri-Iodobenzoicos / Iohexol / Angiografia Coronária / Meios de Contraste / Angiografia por Tomografia Computadorizada Idioma: En Ano de publicação: 2018 Tipo de documento: Article