Z-spectrum appearance and interpretation in the presence of fat: Influence of acquisition parameters.
Zhang, Shu; Keupp, Jochen; Wang, Xinzeng; Dimitrov, Ivan; Madhuranthakam, Ananth J; Lenkinski, Robert E; Vinogradov, Elena.
Afiliação
  • Zhang S; Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
  • Keupp J; Philips Research, Hamburg, Germany.
  • Wang X; Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
  • Dimitrov I; Philips Medical Systems, Gainesville, Florida, USA.
  • Madhuranthakam AJ; Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
  • Lenkinski RE; Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
  • Vinogradov E; Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
Magn Reson Med ; 79(5): 2731-2737, 2018 05.
Article em En | MEDLINE | ID: mdl-28862349
PURPOSE: Chemical exchange saturation transfer (CEST) MRI is increasingly evolving from brain to body applications. One of the known problems in the body imaging is the presence of strong lipid signals. Although their influence on the CEST effect is acknowledged, there was no study that focuses on the interplay among echo time, fat fraction, and Z-spectrum. This study strives to address these points, with the emphasis on the application in the breast. METHODS: Z-spectra were simulated in phase and out of phase of the main fat peak at -3.4 ppm, with the fat fraction varying from 0 to 100%. The magnetization transfer ratio asymmetry in two ranges, centering at the exchanging pool and at 3.5 ppm approximately opposite the nonexchanging fat pool, were calculated and were plotted against fat fraction. The results were verified in phantoms and in vivo. RESULTS: The results demonstrate the combined influence of fat fraction and echo time on the Z-spectrum for gradient echo based CEST acquisitions. The influence is straightforward in the in-phase images, but it is more complicated in the out-of-phase images, potentially leading to erroneous CEST contrast. CONCLUSIONS: This study provides a basis for understanding the origin and appearance of lipid artifacts in CEST imaging, and lays the foundation for their efficient removal. Magn Reson Med 79:2731-2737, 2018. © 2017 International Society for Magnetic Resonance in Medicine.