Your browser doesn't support javascript.
loading
Downgrading of Breast Masses Suspicious for Cancer by Using Optoacoustic Breast Imaging.
Menezes, Gisela L G; Pijnappel, Ruud M; Meeuwis, Carla; Bisschops, Robertus; Veltman, Jeroen; Lavin, Philip T; van de Vijver, Marc J; Mann, Ritse M.
Afiliação
  • Menezes GLG; From the Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, E01.132, P.O. Box 85500, 3508, GA Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, the Netherlands (G.L.G.M., R.M.P.); Department of Radiology, Rijnstate Hospital, Arnhem, the Netherlands (C.M.); Department of Ra
  • Pijnappel RM; From the Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, E01.132, P.O. Box 85500, 3508, GA Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, the Netherlands (G.L.G.M., R.M.P.); Department of Radiology, Rijnstate Hospital, Arnhem, the Netherlands (C.M.); Department of Ra
  • Meeuwis C; From the Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, E01.132, P.O. Box 85500, 3508, GA Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, the Netherlands (G.L.G.M., R.M.P.); Department of Radiology, Rijnstate Hospital, Arnhem, the Netherlands (C.M.); Department of Ra
  • Bisschops R; From the Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, E01.132, P.O. Box 85500, 3508, GA Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, the Netherlands (G.L.G.M., R.M.P.); Department of Radiology, Rijnstate Hospital, Arnhem, the Netherlands (C.M.); Department of Ra
  • Veltman J; From the Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, E01.132, P.O. Box 85500, 3508, GA Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, the Netherlands (G.L.G.M., R.M.P.); Department of Radiology, Rijnstate Hospital, Arnhem, the Netherlands (C.M.); Department of Ra
  • Lavin PT; From the Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, E01.132, P.O. Box 85500, 3508, GA Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, the Netherlands (G.L.G.M., R.M.P.); Department of Radiology, Rijnstate Hospital, Arnhem, the Netherlands (C.M.); Department of Ra
  • van de Vijver MJ; From the Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, E01.132, P.O. Box 85500, 3508, GA Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, the Netherlands (G.L.G.M., R.M.P.); Department of Radiology, Rijnstate Hospital, Arnhem, the Netherlands (C.M.); Department of Ra
  • Mann RM; From the Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, E01.132, P.O. Box 85500, 3508, GA Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, the Netherlands (G.L.G.M., R.M.P.); Department of Radiology, Rijnstate Hospital, Arnhem, the Netherlands (C.M.); Department of Ra
Radiology ; 288(2): 355-365, 2018 08.
Article em En | MEDLINE | ID: mdl-29664342
Purpose To assess the ability of optoacoustic (OA) ultrasonography (US) to help correctly downgrade benign masses classified as Breast Imaging Reporting and Data System (BI-RADS) 4a and 4b to BI-RADS 3 or 2. Materials and Methods OA/US technology uses laser light to detect relative amounts of oxygenated and deoxygenated hemoglobin in and around suspicious breast masses. In this prospective, multicenter study, results of 209 patients with 215 breast masses classified as BI-RADS 4a or 4b at US are reported. Patients were enrolled between 2015 and 2016. Masses were first evaluated with US with knowledge of previous clinical information and imaging results, and from this information a US imaging-based probability of malignancy (POM) and BI-RADS category were assigned to each mass. The same masses were then re-evaluated at OA/US. During the OA/US evaluation, radiologists scored five OA/US features, and then reassigned an OA/US-based POM and BI-RADS category for each mass. BI-RADS downgrade and upgrade percentages at OA/US were assessed by using a weighted sum of the five OA feature scores. Results At OA/US, 47.9% (57 of 119; 95% CI: 0.39, 0.57) of benign masses classified as BI-RADS 4a and 11.1% (three of 27; 95% CI: 0.03, 0.28) of masses classified as BI-RADS 4b were correctly downgraded to BI-RADS 3 or 2. Two of seven malignant masses classified as BI-RADS 4a at US were incorrectly downgraded, and one of 60 malignant masses classified as BI-RADS 4b at US was incorrectly downgraded for a total of 4.5% (three of 67; 95% CI: 0.01, 0.13) false-negative findings. Conclusion At OA/US, benign masses classified as BI-RADS 4a could be downgraded in BI-RADS category, which would potentially decrease biopsies negative for cancer and short-interval follow-up examinations, with the limitation that a few masses may be inappropriately downgraded.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Ultrassonografia Mamária / Técnicas Fotoacústicas Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Ultrassonografia Mamária / Técnicas Fotoacústicas Idioma: En Ano de publicação: 2018 Tipo de documento: Article