Transient acute left ventricular dysfunction post-pericardiocentesis for cardiac tamponade.
Sng, Chong Yu Edwin; Koh, Choong Hou; Lomarda, Aileen Mae; Tan, Swee Yaw.
Afiliação
  • Sng CYE; National Heart Centre, Singapore.
  • Koh CH; National Heart Centre, Singapore.
  • Lomarda AM; National Heart Centre, Singapore.
  • Tan SY; National Heart Centre, Singapore.
J Cardiol Cases ; 12(4): 133-137, 2015 Oct.
Article em En | MEDLINE | ID: mdl-30546577
ABSTRACT
A rare but serious complication of pericardiocentesis is the development of transient left ventricular dysfunction. In this report, we present a case of a 65-year-old male patient with cardiac tamponade who suffered from acute left ventricular heart failure post-pericardiocentesis. <Learning

objective:

Acute left ventricular dysfunction is a rare but serious complication of pericardiocentesis. However, there is lack of existing guidelines on pericardial fluid drainage and monitoring post-pericardiocentesis. To minimize the risk of the development of acute left ventricular dysfunction, the authors propose that every pericardiocentesis should be guided by predetermined parameters, e.g. rate of drainage, while taking into account each patient's physical profile.>.