Virtual versus true non-contrast dual-energy CT imaging for the diagnosis of aortic intramural hematoma.
Eur Radiol
; 29(12): 6762-6771, 2019 Dec.
Article
em En
| MEDLINE
| ID: mdl-31264015
PURPOSE: To assess whether virtual non-contrast (VNC) images derived from contrast dual-layer dual-energy computed tomography (DL-DECT) images could replace true non-contrast (TNC) images for aortic intramural hematoma (IMH) diagnosis in acute aortic syndrome (AAS) imaging protocols by performing quantitative as well as qualitative phantom and clinical studies. MATERIALS AND METHODS: Patients with confirmed IMH were included retrospectively in two centers. For in vitro imaging, a custom-made phantom of IMH was placed in a semi-anthropomorphic thorax phantom (QRM GmbH) and imaged on a DL-DECT at 120 kVp under various conditions of patient size, radiation exposure, and reconstruction modes. For in vivo imaging, 21 patients (70 ± 13 years) who underwent AAS imaging protocols at 120 kVp were included. In both studies, contrast-to-noise ratio (CNR) between hematoma and lumen was compared using a paired t test. Diagnostic confidence (1 = non-diagnostic, 4 = exemplary) for VNC and TNC images was rated by two radiologists and compared. Effective radiation doses for each acquisition were calculated. RESULTS: In both the phantom and clinical studies, we observed that the CNRs were similar between the VNC and TNC images. Moreover, both methods allowed differentiating the hyper-attenuation within the hematoma from the blood. Finally, we obtained equivalent high diagnostic confidence with both VNC and TNC images (VNC = 3.2 ± 0.7, TNC = 3.1 ± 0.7; p = 0.3). Finally, by suppressing TNC acquisition and using VNC, the mean effective dose reduction would be 40%. CONCLUSION: DL-DECT offers similar performances with VNC and TNC images for IMH diagnosis without compromise in diagnostic image quality. KEY POINTS: ⢠Dual-layer dual-energy CT enables virtual non-contrast imaging from a contrast-enhanced acquisition. ⢠Virtual non-contrast imaging with dual-layer dual-energy CT reduces the number of acquisitions and radiation exposure in acute aortic syndrome imaging protocol. ⢠Dual-layer dual-energy CT has the potential to become a suitable imaging tool for acute aortic syndrome.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Doenças da Aorta
/
Tomografia Computadorizada por Raios X
/
Hematoma
Idioma:
En
Ano de publicação:
2019
Tipo de documento:
Article
País de afiliação:
França