Allergic responses are mainly caused by IgE, which is often located on the cell surface. The current diagnostic method detects both allergen-specific IgE and total IgE levels, but a number of allergic patients have a normal serum IgE level, which is a poor clinical correlate for allergy. Here, we developed a simple method to detect the level of cell-bound IgE by dissociating it from blood cells with lactic acid. Dissociated cell-bound IgE and plasma IgE levels were detected using the same ELISA kit at the same time. We established two clinical cohorts: an allergic patient group and a healthy participant group. In general, cell-bound IgE correlated well with plasma IgE; however, some patients exhibited high cell-bound IgE levels but low plasma IgE levels. We recommended 350 ng/mL peripheral blood total IgE (cell-bound IgE + plasma IgE) as the cut-off value for allergy diagnosis. Using this indicator, 90.32% of our allergic patients were correctly diagnosed. The peripheral blood total IgE level is a promising clinical diagnostic indicator in allergic patients and will provide more guidance for allergy diagnosis and therapeutic evaluation.