In search of a one plan solution for VMAT post-mastectomy chest wall irradiation.
Monajemi, T T; Oliver, P A K; Day, A; Yewondwossen, M.
Afiliação
  • Monajemi TT; Department of Radiation Oncology, Dalhousie University, Halifax, Nova Scotia, Canada.
  • Oliver PAK; Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada.
  • Day A; Department of Radiation Oncology, Dalhousie University, Halifax, Nova Scotia, Canada.
  • Yewondwossen M; Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada.
J Appl Clin Med Phys ; 21(8): 216-223, 2020 Aug.
Article em En | MEDLINE | ID: mdl-32592451
PURPOSE: This study was designed to evaluate skin dose in both VMAT and tangent treatment deliveries for the purpose of identifying suitable bolus use protocols that should produce similar superficial doses. METHODS: Phantom measurements were used to investigate skin dose in chest wall radiotherapy with and without bolus for 3D and rotational treatment techniques. Optically stimulated luminescence dosimeters (OSLDs) with and without housing and EBT3 film were used. Superflab (3, 5, and 10 mm) and brass mesh were considered. Measured doses were compared with predictions by the Eclipse treatment planning system. Patient measurements were also performed and the bolusing effect of hospital gowns and blankets were highlighted. The effect of flash for VMAT plans was considered experimentally by using 2 mm couch shifts. RESULTS: For tangents, average skin doses without bolus were 0.64 (EBT3), 0.62 (bare OSLD), 0.77 (jacketed OSLD), and 0.68 (Eclipse) as a fraction of prescription. For VMAT, doses without bolus were 0.53 (EBT3), 0.53 (bare OSLD), 0.64 (jacketed OSLD), and 0.60 (Eclipse). For tangents, the average doses with different boluses as measured by EBT3 were 0.99 (brass mesh), 1.02 (3 mm), 1.03 (5 mm), and 1.07 (10 mm). For VMAT with bolus, average doses as measured by EBT3 were 0.83 (brass), 0.96 (3 mm), 1.03 (5 mm), and 1.04 (10 mm). Eclipse doses agreed with measurements to within 5% of measurements for all Superflab thicknesses and within 15% of measurements for no bolus. The presence of a hospital gown and blanket had a bolusing effect that increased the surface dose by approximately 10%. CONCLUSIONS: Results of this work allow for consideration of different bolus thicknesses, materials, and usage schedules based on desired skin dose and choice of either tangents or an arc beam techniques.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Parede Torácica / Radioterapia de Intensidade Modulada Idioma: En Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Parede Torácica / Radioterapia de Intensidade Modulada Idioma: En Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Canadá