Your browser doesn't support javascript.
loading
Development of ratiometric electrochemical molecular switches to assay endogenous formaldehyde in live cells, whole blood and creatinine in saliva.
Kumaravel, Sakthivel; Wu, Shao-Hsuan; Chen, Guan-Zhang; Huang, Sheng-Tung; Lin, Chun-Mao; Lee, Yu-Chieh; Chen, Ching-Hui.
Afiliação
  • Kumaravel S; Institute of Biochemical and Biomedical Engineering, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan.
  • Wu SH; Institute of Biochemical and Biomedical Engineering, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan.
  • Chen GZ; Institute of Biochemical and Biomedical Engineering, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan.
  • Huang ST; Institute of Biochemical and Biomedical Engineering, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan. Electronic address: ws75624@ntut.edu.tw.
  • Lin CM; Department of Biochemistry and Molecular Cell Biology, College of Medicine, Taipei Medical University, Taipei, 11031, Taiwan.
  • Lee YC; Department of Obstetrics and Gynecology, Taipei Medical University Hospital, Taipei, 11031, Taiwan.
  • Chen CH; Department of Obstetrics and Gynecology, Taipei Medical University Hospital, Taipei, 11031, Taiwan.
Biosens Bioelectron ; 171: 112720, 2021 Jan 01.
Article em En | MEDLINE | ID: mdl-33059167
ABSTRACT
Formaldehyde is a reactive carbonyl species (RCS) that is produced naturally in the human body via metabolic and epigenetic biochemical processes, yet in high concentrations is highly toxic to the environment as well as to living organisms. Therefore, we designed two ratiometric electrochemical molecular redox probes, Formaldehyde oxidative latent probe (FOLP) and dihydroxy-formaldehyde oxidative latent probe (HFOLP), for the selective profiling of endogenous formaldehyde. FOLP and HFOLP each underwent the aza-Cope reaction with formaldehyde followed by hydrolysis to eliminate unmask redox reporter N-alkylated aminoferrocene (AAF) to monitor their response current. The FOLP and HFOLP sensors showed broad dynamic ranges of 0.12-1000 µM and 0.09-3 mM for formaldehyde with detection limits of 48.2 nM and 31.6 µM, respectively. Also, since formaldehyde is the byproduct of biochemical reactions for detecting creatinine and creatinine is an important biomarker for chronic kidney disease (CKD), we tested the FOLP probe for its ability to monitor creatinine. It successfully did so, and this ability was used to develop an electrochemical platform for the quantification of creatinine; it showed a dynamic range of 3.25-200 µM and a limit of detection (1.3 µM). In addition, the FOLP-based assay platform delivered a reliable analytical performance for the quantification of formaldehyde in human whole blood and of creatinine in saliva, and also for the real-time monitoring of endogenous formaldehyde secretion in HeLa cells. Moreover, the concentrations determined using our method were found to be consistent with those determined using formaldehyde and creatinine fluorometric assay kits.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Saliva / Técnicas Biossensoriais Idioma: En Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Saliva / Técnicas Biossensoriais Idioma: En Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Taiwan