Your browser doesn't support javascript.
loading
Improved method for post-processing correction of B1 inhomogeneity in glutamate-weighted CEST images of the human brain.
Cember, Abigail T J; Hariharan, Hari; Kumar, Dushyant; Nanga, Ravi P R; Reddy, Ravinder.
Afiliação
  • Cember ATJ; Center for Magnetic Resonance and Optical Imaging, Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Hariharan H; Graduate Group in Biochemistry and Molecular Biophysics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Kumar D; Center for Magnetic Resonance and Optical Imaging, Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Nanga RPR; Center for Magnetic Resonance and Optical Imaging, Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Reddy R; Center for Magnetic Resonance and Optical Imaging, Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
NMR Biomed ; 34(6): e4503, 2021 06.
Article em En | MEDLINE | ID: mdl-33749037
Glutamate-weighted CEST (gluCEST) imaging is nearly unique in its ability to provide non-invasive, spatially resolved measurements of glutamate in vivo. In this article, we present an improved correction for B1 inhomogeneity of gluCEST images of the human brain. Images were obtained on a Siemens 7.0 T Terra outfitted with a single-volume transmit/32-channel receive phased array head coil. Numerical Bloch-McConnell simulations, fitting and data processing were performed using in-house code written in MATLAB and MEX (MATLAB executable). "Calibration" gluCEST data was acquired and fit with a phenomenological functional form first described here. The resulting surfaces were used to correct experimental data in accordance with a newly developed method. Healthy volunteers of varying ages were used for both fitted "calibration" data and corrected "experimental" data. Simulations allowed us to describe the dependence of CEST at 3.0 ppm (gluCEST) on saturation B1 using a new functional form, whose validity was confirmed by successful fitting to real human data. This functional form was used to parameterize surfaces over the space (B1 , T1 ), which could then be used to correct the signal from each pixel. The resulting images show less signal loss in areas of low B1 and greater contrast than those generated using the previously published method. We demonstrate that, using this method with appropriate nominal saturation B1 , the major limitation of correcting for B1 inhomogeneity becomes the effective flip angle of the acquisition module, rather than inability to correct for inhomogeneous saturation. The lower limit of our correction ability with respect to both saturation and acquisition B1 is about 40% of the nominal value. In summary, we demonstrate a more rigorous and successful approach to correcting gluCEST images for B1 inhomogeneity. Limitations of the method and further improvements to enable correction in regions with severe pathology are discussed.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Encéfalo / Imageamento por Ressonância Magnética / Ácido Glutâmico Idioma: En Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Encéfalo / Imageamento por Ressonância Magnética / Ácido Glutâmico Idioma: En Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos