Your browser doesn't support javascript.
loading
Development of Broadband High-Frequency Piezoelectric Micromachined Ultrasonic Transducer Array.
Wang, Xu-Bo; He, Le-Ming; Ma, You-Cao; Liu, Wen-Juan; Xu, Wei-Jiang; Ren, Jun-Yan; Riaud, Antoine; Zhou, Jia.
Afiliação
  • Wang XB; State Key Laboratory of ASIC and System, School of Microelectronics, Fudan University, Shanghai 201203, China.
  • He LM; State Key Laboratory of ASIC and System, School of Microelectronics, Fudan University, Shanghai 201203, China.
  • Ma YC; State Key Laboratory of ASIC and System, School of Microelectronics, Fudan University, Shanghai 201203, China.
  • Liu WJ; State Key Laboratory of ASIC and System, School of Microelectronics, Fudan University, Shanghai 201203, China.
  • Xu WJ; Univ. Polytechnique Hauts-de-France, CNRS, Univ. Lille, Centrale Lille, UMR 8520-IEMN, DOAE, F-59313 Valenciennes, France.
  • Ren JY; Univ. Polytechnique Hauts-de-France, CNRS, Univ. Lille, Centrale Lille, UMR 8520-IEMN, DOAE, F-59313 Valenciennes, France.
  • Riaud A; INSA Hauts-de-France, Le Mont Houy, F-59313 Valenciennes, France.
  • Zhou J; State Key Laboratory of ASIC and System, School of Microelectronics, Fudan University, Shanghai 201203, China.
Sensors (Basel) ; 21(5)2021 Mar 05.
Article em En | MEDLINE | ID: mdl-33807831
Piezoelectric micromachined ultrasonic transducers (PMUT) are promising elements to fabricate a two-dimensional (2D) array with a pitch small enough (approximately half wavelength) to form and receive arbitrary acoustic beams for medical imaging. However, PMUT arrays have so far failed to combine the wide, high-frequency bandwidth needed to achieve a high axial resolution. In this paper, a polydimethylsiloxane (PDMS) backing structure is introduced into the PMUTs to improve the device bandwidth while keeping a sub-wavelength (λ) pitch. We implement this backing on a 16 × 8 array with 75 µm pitch (3λ/4) with a 15 MHz working frequency. Adding the backing nearly doubles the bandwidth to 92% (-6 dB) and has little influence on the impulse response sensitivity. By widening the transducer bandwidth, this backing may enable using PMUT ultrasonic arrays for high-resolution 3D imaging.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China