Your browser doesn't support javascript.
loading
Factors associated with missing strings and expulsion after postplacental insertion of copper T380A intrauterine devices.
da Silva Nóbrega, Aureliana Barboza; Pitangui, Ana Carolina Rodarti; Vieira, Carolina Sales.
Afiliação
  • da Silva Nóbrega AB; Department of Obstetrics and Gynecology, Center of Medical Sciences, Federal University of Paraíba, João Pessoa, PB, Brazil.
  • Pitangui ACR; Department of Nursing, University of Pernambuco, Recife, PE, Brazil.
  • Vieira CS; Department of Gynecology and Obstetrics, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, SP, Brazil.
Int J Gynaecol Obstet ; 157(1): 67-75, 2022 Apr.
Article em En | MEDLINE | ID: mdl-34197636
ABSTRACT

OBJECTIVE:

To identify clinical and demographic factors associated with missing strings and expulsion after postplacental insertion of copper T380A intrauterine devices (TCu380A IUD).

METHODS:

This is a secondary analysis of an implementation study. We followed participants who had a postplacental TCu380A IUD insertion, at two postpartum visits 45-90 days (visit 1) and 6-9 months (visit 2). We used multiple log-binomial regression models to evaluate the demographic and clinical variables associated with missing strings and with IUD expulsion.

RESULTS:

We included 705 participants who had a postplacental IUD insertion. We observed missing strings in 275 (47.9%) participants at visit 1, and in 127 (34.2%) participants at visit 2. We identified 61 expulsions (8.9%) by visit 2. In the multiple regression models, only the delivery type was associated with missing strings and expulsion. Compared with vaginal delivery, cesarean delivery increased the risk of missing strings (adjusted relative risk [aRR] 6.21; 95% confidence interval [CI] 4.29-8.99) but reduced the risk of IUD expulsion (aRR 0.24; 95% CI 0.13-0.43).

CONCLUSION:

The delivery mode was the only factor associated with missing strings and expulsion after postplacental IUD insertion. Cesarean section was associated with an increased risk of missing strings but decreased risk of expulsion after postplacental TCu380A IUD insertion.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Dispositivos Intrauterinos / Dispositivos Intrauterinos de Cobre Idioma: En Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Dispositivos Intrauterinos / Dispositivos Intrauterinos de Cobre Idioma: En Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil