Your browser doesn't support javascript.
loading
Endobiliary Radiofrequency Ablation Using a Short-Type Balloon Enteroscope in Patients with Surgically Altered Anatomy.
Inoue, Tadahisa; Ibusuki, Mayu; Kitano, Rena; Sakamoto, Kazumasa; Kimoto, Satoshi; Kobayashi, Yuji; Ohashi, Tomohiko; Sumida, Yoshio; Nakade, Yukiomi; Ito, Kiyoaki; Yoneda, Masashi.
Afiliação
  • Inoue T; Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan. tinoue-tag@umin.ac.jp.
  • Ibusuki M; Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
  • Kitano R; Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
  • Sakamoto K; Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
  • Kimoto S; Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
  • Kobayashi Y; Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
  • Ohashi T; Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
  • Sumida Y; Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
  • Nakade Y; Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
  • Ito K; Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
  • Yoneda M; Department of Gastroenterology, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.
Dig Dis Sci ; 67(8): 4181-4187, 2022 08.
Article em En | MEDLINE | ID: mdl-34410572
BACKGROUND: Endoscopic radiofrequency ablation (RFA) is expected to prolong stent patency for malignant biliary obstruction (MBO). However, its feasibility when used in conjunction with a balloon enteroscope (BE) in patients with surgically altered anatomy (SAA) remains unknown. AIMS: This study aimed to investigate the feasibility of RFA combined with metal stent insertion under BE guidance for MBO in patients with SAA. METHODS: Thirty-seven patients who underwent treatment between October 2016 and January 2021 and met the eligibility criteria were investigated retrospectively. Study outcomes included technical and clinical success, recurrent biliary obstruction (RBO), and other adverse events besides RBO associated with RFA with metal stent placement using BE. RESULTS: Technical and clinical success rates were 100% (37/37) each. The rates of early and late adverse events were 8.1% (3/37) and 8.1% (3/37), respectively. RBO occurred in 32.4% (12/37) of the patients, and the median time to RBO was 296 days. The cause of RBO was ingrowth in eight patients, overgrowth in three patients, and indeterminate in one patient. All reinterventions for RBO were successful using the BE approach; all ingrowths, except one, were recanalized using additional RFA without additional stent placement. The frequency of reintervention-related adverse events was 9.1% (1/11). The median time to RBO after reintervention was 166 days. CONCLUSIONS: This study demonstrated the technical safety and feasibility as well as good long-term outcomes of endobiliary RFA combined with metal stent placement under BE guidance. This approach may be a useful option for treating MBO in patients with SAA.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias dos Ductos Biliares / Colestase / Ablação por Cateter Idioma: En Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias dos Ductos Biliares / Colestase / Ablação por Cateter Idioma: En Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Japão