Your browser doesn't support javascript.
loading
Rapid Optical Biosensing of SARS-CoV-2 Spike Proteins in Artificial Samples.
Tao, Ying; Bian, Sumin; Wang, Pengbo; Zhang, Hongyong; Bi, Wenwen; Zhu, Peixi; Sawan, Mohamad.
Afiliação
  • Tao Y; College of Pharmaceutical Sciences, Zhejiang University of Technology, Hangzhou 310014, China.
  • Bian S; CenBRAIN Lab, School of Engineering, Westlake University, Hangzhou 310024, China.
  • Wang P; CenBRAIN Lab, School of Engineering, Westlake University, Hangzhou 310024, China.
  • Zhang H; CenBRAIN Lab, School of Engineering, Westlake University, Hangzhou 310024, China.
  • Bi W; CenBRAIN Lab, School of Engineering, Westlake University, Hangzhou 310024, China.
  • Zhu P; Key Laboratory of Structural Biology of Zhejiang Province, School of Life Science, Westlake University, Hangzhou 310024, China.
  • Sawan M; Institute of Biology, Westlake Institute for Advanced Study, Hangzhou 310024, China.
Sensors (Basel) ; 22(10)2022 May 16.
Article em En | MEDLINE | ID: mdl-35632177
ABSTRACT
Tests for SARS-CoV-2 are crucial for the mass surveillance of the incidence of infection. The long waiting time for classic nucleic acid test results highlights the importance of developing alternative rapid biosensing methods. Herein, we propose a fiber-optic biolayer interferometry-based biosensor (FO-BLI) to detect SARS-CoV-2 spike proteins, extracellular domain (ECD), and receptor-binding domain (RBD) in artificial samples in 13 min. The FO-BLI biosensor utilized an antibody pair to capture and detect the spike proteins. The secondary antibody conjugated with horseradish peroxidase (HRP) reacted with the enzyme substrate for signal amplification. Two types of substrates, 3,3'-diaminobenzidine (DAB) and an advanced 3-Amino-9-ethylcarbazole (i.e., AMEC), were applied to evaluate their capabilities in enhancing signals and reaching high sensitivity. After careful comparison, the AMEC-based FO-BLI biosensor showed better assay performance, which detected ECD at a concentration of 32-720 pM and RBD of 12.5-400 pM in artificial saliva and serum, respectively. The limit of detection (LoD) for SARS-CoV-2 ECD and RBD was defined to be 36 pM and 12.5 pM, respectively. Morphology of the metal precipitates generated by the AMEC-HRP reaction in the fiber tips was observed using field emission scanning electron microscopy (SEM). Collectively, the developed FO-BLI biosensor has the potential to rapidly detect SARS-CoV-2 antigens and provide guidance for "sample-collect and result-out on-site" mode.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Glicoproteína da Espícula de Coronavírus / COVID-19 Idioma: En Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Glicoproteína da Espícula de Coronavírus / COVID-19 Idioma: En Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China