Your browser doesn't support javascript.
loading
Investigation of CFRP Reinforcement Ratio on the Flexural Capacity and Failure Mode of Plain Concrete Prisms.
Qureshi, Hisham Jahangir; Saleem, Muhammad Umair; Khurram, Nauman; Ahmad, Jawad; Amin, Muhammad Nasir; Khan, Kaffayatullah; Aslam, Fahid; Al Fuhaid, Abdulrahman Fahad; Arifuzzaman, Md.
Afiliação
  • Qureshi HJ; Department of Civil and Environmental Engineering, College of Engineering, King Faisal University, Al-Ahsa 31982, Saudi Arabia.
  • Saleem MU; Service Stream Limited Co., Chatswood, NSW 2067, Australia.
  • Khurram N; Department of Civil Engineering, University of Engineering and Technology Lahore, Lahore 54890, Pakistan.
  • Ahmad J; Department of Civil Engineering, Swedish College of Engineering, Wah Cantt 47040, Pakistan.
  • Amin MN; Department of Civil and Environmental Engineering, College of Engineering, King Faisal University, Al-Ahsa 31982, Saudi Arabia.
  • Khan K; Department of Civil and Environmental Engineering, College of Engineering, King Faisal University, Al-Ahsa 31982, Saudi Arabia.
  • Aslam F; Department of Civil Engineering, Prince Sattam Bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia.
  • Al Fuhaid AF; Department of Civil and Environmental Engineering, College of Engineering, King Faisal University, Al-Ahsa 31982, Saudi Arabia.
  • Arifuzzaman M; Department of Civil and Environmental Engineering, College of Engineering, King Faisal University, Al-Ahsa 31982, Saudi Arabia.
Materials (Basel) ; 15(20)2022 Oct 17.
Article em En | MEDLINE | ID: mdl-36295312
The utilization of carbon-fiber-reinforced polymer (CFRP) composites as strengthening materials for structural components has become quite famous over the last couple of decades. The present experimental study was carried out to examine the effect of varied widths of externally bonded CFRP on the debonding strain of CFRP and the failure mode of plain concrete beams. Twelve plain concrete prims measuring 100 mm × 100 mm × 500 mm were cast and tested under identical loading conditions. The twelve specimens include two control prisms, i.e., without CFRP strips, and the remaining ten prisms were reinforced with CFRP strips with widths of 10 mm, 20 mm, 30 mm, 40 mm, and 50 mm, respectively, i.e., two prisms in each group. Four-point loading flexural testing was carried out, and the resulting data are presented in the form of peak load vs. midpoint displacement, load vs. concrete strain, and load vs. CFRP strain. The peak load was directly recorded from the testing machine, while the midpoint deflection was recorded through the linear variable differential transducer (LVDT) installed at the midpoint. To measure the strain, two separate strain gauges were installed at the bottom of each concrete prism, i.e., one on the concrete surface and the other on the surface of the CFRP strip. The results of this study indicate that the debonding strain is a function of CFRP strip width and that the failure patterns of beams are significantly affected by the CFRP reinforcement ratio.