Your browser doesn't support javascript.
loading
To compare the influence of blind insertion and up-down optimized glottic exposure manoeuvre on oropharyngeal leak pressure using SaCoVLM™ video laryngeal mask among patients undergoing general anesthesia.
Yan, Chun-Ling; Zhang, Yi-Qi-Yuan; Chen, Ying; Qv, Zong-Yang; Zuo, Ming-Zhang.
Afiliação
  • Yan CL; Department of Anesthesia, Institute of Geriatric Medicine, Beijing Hospital, National Center of Gerontology, Chinese Academy of Medical Sciences, Beijing, People's Republic of China.
  • Zhang YQ; Department of Anesthesia, Institute of Geriatric Medicine, Beijing Hospital, National Center of Gerontology, Chinese Academy of Medical Sciences, Beijing, People's Republic of China.
  • Chen Y; Department of Anesthesia, Institute of Geriatric Medicine, Beijing Hospital, National Center of Gerontology, Chinese Academy of Medical Sciences, Beijing, People's Republic of China.
  • Qv ZY; Department of Anesthesia, Institute of Geriatric Medicine, Beijing Hospital, National Center of Gerontology, Chinese Academy of Medical Sciences, Beijing, People's Republic of China.
  • Zuo MZ; Department of Anesthesia, Institute of Geriatric Medicine, Beijing Hospital, National Center of Gerontology, Chinese Academy of Medical Sciences, Beijing, People's Republic of China. zuomz@163.com.
J Clin Monit Comput ; 37(2): 593-598, 2023 04.
Article em En | MEDLINE | ID: mdl-36308611
ABSTRACT
To compare the potential influences of blind insertion and up-down optimized glottic exposure manoeuvre on the oropharyngeal leak pressure (OPLP) in using SaCoVLM™ video laryngeal mask (VLM) among patients undergoing general anesthesia. A randomized self-control study controlled was conducted to investigate the effect of two insertion techniques on OPLP. A total of 60 patients (male or female, 18-78 years, BMI 18.0-30.0 kg m-2 and ASA I-II) receiving selective surgery under general anesthesia were randomly recruited. After induction of anesthesia, the SaCoVLM™ was inserted by blind insertion manoeuvre. The glottic exposure grading(V1) of the SaCoVLM™ visual laryngeal mask and the OPLP(P1) were recorded. And the glottic exposure grading(V2) and OPLP(P2) of SaCoVLM™ were recorded again when the glottic exposure grading was optimal. The glottis exposure grading and OPLP were compared before and after different insertion manoeuver. The glottic exposure grading (V2) obtained by using up-down optimized glottic exposure manoeuvre was better than that obtained by using blind insertion manoeuvre (V1)(P < 0.001). The OPLP was significantly lower in the blind insertion manoeuvre (P1) than in the up-down optimized glottic exposure manoeuvre (P2) (32.4 ± 5.0 cmH2O vs. 36.3 ± 5.2 cmH2O, P < 0.001). In using SaCoVLM™, higher OPLP and better glottic exposure grading were achieved through up-down optimized glottic exposure manoeuvre, protecting the airway while real-time monitoring of conditions around the glottis, which significantly improves airway safety. Our results suggests that up-down optimized glottic exposure manoeuver may be a useful technique for SaCoVLM™ insertion.Trial registration ChiCTR, ChiCTR2000028802. Registered 4 January 2020, http//www.chictr.org.cn/ChiCTR2000028802.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Máscaras Laríngeas / Anestesiologia Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Máscaras Laríngeas / Anestesiologia Idioma: En Ano de publicação: 2023 Tipo de documento: Article