Focused navigation for respiratory-motion-corrected free-running radial 4D flow MRI.
Falcão, Mariana B L; Rossi, Giulia M C; Rutz, Tobias; Prsa, Milan; Tenisch, Estelle; Ma, Liliana; Weiss, Elizabeth K; Baraboo, Justin J; Yerly, Jérôme; Markl, Michael; Stuber, Matthias; Roy, Christopher W.
Afiliação
  • Falcão MBL; Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.
  • Rossi GMC; Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.
  • Rutz T; Service of Cardiology, Centre de Resonance Magnétique Cardiaque (CRMC), Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Prsa M; Woman-Mother-Child Department, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Tenisch E; Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.
  • Ma L; Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.
  • Weiss EK; Department of Biomedical Engineering, Northwestern University, Chicago, Illinois, USA.
  • Baraboo JJ; Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.
  • Yerly J; Department of Biomedical Engineering, Northwestern University, Chicago, Illinois, USA.
  • Markl M; Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.
  • Stuber M; Department of Biomedical Engineering, Northwestern University, Chicago, Illinois, USA.
  • Roy CW; Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland.
Magn Reson Med ; 90(1): 117-132, 2023 07.
Article em En | MEDLINE | ID: mdl-36877140
PURPOSE: To validate a respiratory motion correction method called focused navigation (fNAV) for free-running radial whole-heart 4D flow MRI. METHODS: Using fNAV, respiratory signals derived from radial readouts are converted into three orthogonal displacements, which are then used to correct respiratory motion in 4D flow datasets. Hundred 4D flow acquisitions were simulated with non-rigid respiratory motion and used for validation. The difference between generated and fNAV displacement coefficients was calculated. Vessel area and flow measurements from 4D flow reconstructions with (fNAV) and without (uncorrected) motion correction were compared to the motion-free ground-truth. In 25 patients, the same measurements were compared between fNAV 4D flow, 2D flow, navigator-gated Cartesian 4D flow, and uncorrected 4D flow datasets. RESULTS: For simulated data, the average difference between generated and fNAV displacement coefficients was 0.04 ± $$ \pm $$ 0.32 mm and 0.31 ± $$ \pm $$ 0.35 mm in the x and y directions, respectively. In the z direction, this difference was region-dependent (0.02 ± $$ \pm $$ 0.51 mm up to 5.85 ± $$ \pm $$ 3.41 mm). For all measurements (vessel area, net volume, and peak flow), the average difference from ground truth was higher for uncorrected 4D flow datasets (0.32 ± $$ \pm $$ 0.11 cm2 , 11.1 ± $$ \pm $$ 3.5 mL, and 22.3 ± $$ \pm $$ 6.0 mL/s) than for fNAV 4D flow datasets (0.10 ± $$ \pm $$ 0.03 cm2 , 2.6 ± $$ \pm $$ 0.7 mL, and 5.1 ± 0 $$ \pm 0 $$ .9 mL/s, p < 0.05). In vivo, average vessel area measurements were 4.92 ± $$ \pm $$ 2.95 cm2 , 5.06 ± $$ \pm $$ 2.64 cm2 , 4.87 ± $$ \pm $$ 2.57 cm2 , 4.87 ± $$ \pm $$ 2.69 cm2 , for 2D flow and fNAV, navigator-gated and uncorrected 4D flow datasets, respectively. In the ascending aorta, all 4D flow datasets except for the fNAV reconstruction had significantly different vessel area measurements from 2D flow. Overall, 2D flow datasets demonstrated the strongest correlation to fNAV 4D flow for both net volume (r2  = 0.92) and peak flow (r2  = 0.94), followed by navigator-gated 4D flow (r2  = 0.83 and r2  = 0.86, respectively), and uncorrected 4D flow (r2  = 0.69 and r2  = 0.86, respectively). CONCLUSION: fNAV corrected respiratory motion in vitro and in vivo, resulting in fNAV 4D flow measurements that are comparable to those derived from 2D flow and navigator-gated Cartesian 4D flow datasets, with improvements over those from uncorrected 4D flow.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Taxa Respiratória Idioma: En Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Suíça