Your browser doesn't support javascript.
loading
AAPM task group report 305: Guidance for standardization of vendor-neutral reject analysis in radiography.
Little, Kevin; Reiser, Ingrid; Apgar, Bruce; Dalal, Poonam; Dave, Jaydev; Fisher, Ryan; Hulme, Katie; Jafari, Mary Ellen; Marshall, Emily; Meyer, Stephen; Moore, Quentin; Murphy, Nicole; Nishino, Thomas; Nye, Katelyn; O'Donnell, Kevin; Sabol, John; Sanchez, Adrian; Sensakovic, William; Tarbox, Lawrence; Uzenoff, Robert; Walz-Flannigan, Alisa; Willis, Charles; Zhang, Jie.
Afiliação
  • Little K; Ohio State University, Columbus, Ohio, USA.
  • Reiser I; The University of Chicago, Chicago, Illinois, USA.
  • Apgar B; AGFA HealthCare, Greenville, South Carolina, USA.
  • Dalal P; GE Healthcare, Chicago, Illinois, USA.
  • Dave J; Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
  • Fisher R; The MetroHealth System, Cleveland, Ohio, USA.
  • Hulme K; Cleveland Clinic, Cleveland, Ohio, USA.
  • Jafari ME; Atlantic Health System, Morristown, New Jersey, USA.
  • Marshall E; The University of Chicago, Chicago, Illinois, USA.
  • Meyer S; Canon Medical Components USA, Irvine, California, USA.
  • Moore Q; Mercy College of Ohio, Toledo, Ohio, USA.
  • Murphy N; Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, Illinois, USA.
  • Nishino T; University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
  • Nye K; GE Healthcare, Chicago, Illinois, USA.
  • O'Donnell K; Canon Medical Research USA, Vernon Hills, Illinois, USA.
  • Sabol J; GE Healthcare, Chicago, Illinois, USA.
  • Sanchez A; Vanderbilt University, Nashville, Tennessee, USA.
  • Sensakovic W; Mayo Clinic, Phoenix, Arizona, USA.
  • Tarbox L; University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA.
  • Uzenoff R; Fujifilm Medical Systems USA, Lexington, Massachusetts, USA.
  • Walz-Flannigan A; Marshfield Clinic, Marshfield, Wisconsin, USA.
  • Willis C; Canon Medical Research USA, Vernon Hills, Illinois, USA.
  • Zhang J; University of Kentucky, Lexington, Kentucky, USA.
J Appl Clin Med Phys ; 24(5): e13938, 2023 May.
Article em En | MEDLINE | ID: mdl-36995917
Reject rate analysis is considered an integral part of a diagnostic radiography quality control (QC) program. A rejected image is a patient radiograph that was not presented to a radiologist for diagnosis and that contributes unnecessary radiation dose to the patient. Reject rates that are either too high or too low may suggest systemic department shortcomings in QC mechanisms. Due to the lack of standardization, reject data often cannot be easily compared between radiography systems from different vendors. The purpose of this report is to provide guidance to help standardize data elements that are required for comprehensive reject analysis and to propose data reporting and workflows to enable an effective and comprehensive reject rate monitoring program. Essential data elements, a proposed schema for classifying reject reasons, and workflow implementation options are recommended in this task group report.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiografia Idioma: En Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiografia Idioma: En Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos