A sensitive and rapid LC-MS/MS assay for quantitation of free payload Aur0101 from antibody drug conjugate (ADC) PYX-201 in human plasma.
Yin, Feng; Adhikari, Diana; Li, Yan; Turner, Devan; Shane Woolf, M; Lebarbenchon, Diane; Ma, Eric; Mylott, William; Shaheen, Elizabeth; Harriman, Shawn; Pinkas, Jan.
Afiliação
  • Yin F; Department of Nonclinical Research, Pyxis Oncology, Inc., 321 Harrison Avenue, Suite 1, Boston, MA 02118, USA.
  • Adhikari D; Department of Nonclinical Research, Pyxis Oncology, Inc., 321 Harrison Avenue, Suite 1, Boston, MA 02118, USA.
  • Li Y; Chromatographic Services - Research & Development, Biologics by LC-MS/MS, PPD Laboratory Services (a part of ThermoFisher Scientific), 8700 Quioccasin Road, Henrico, VA 23229, USA.
  • Turner D; Chromatographic Services - Research & Development, Biologics by LC-MS/MS, PPD Laboratory Services (a part of ThermoFisher Scientific), 8700 Quioccasin Road, Henrico, VA 23229, USA.
  • Shane Woolf M; Chromatographic Services - Research & Development, Biologics by LC-MS/MS, PPD Laboratory Services (a part of ThermoFisher Scientific), 8700 Quioccasin Road, Henrico, VA 23229, USA.
  • Lebarbenchon D; Chromatographic Services - Research & Development, Biologics by LC-MS/MS, PPD Laboratory Services (a part of ThermoFisher Scientific), 8700 Quioccasin Road, Henrico, VA 23229, USA.
  • Ma E; Chromatographic Services - Research & Development, Biologics by LC-MS/MS, PPD Laboratory Services (a part of ThermoFisher Scientific), 8700 Quioccasin Road, Henrico, VA 23229, USA.
  • Mylott W; Chromatographic Services - Research & Development, Biologics by LC-MS/MS, PPD Laboratory Services (a part of ThermoFisher Scientific), 8700 Quioccasin Road, Henrico, VA 23229, USA.
  • Shaheen E; Department of Project Management, Pyxis Oncology, Inc., 321 Harrison Avenue, Suite 1, Boston, MA 02118, USA.
  • Harriman S; Department of Nonclinical Research, Pyxis Oncology, Inc., 321 Harrison Avenue, Suite 1, Boston, MA 02118, USA.
  • Pinkas J; Department of Nonclinical Research, Pyxis Oncology, Inc., 321 Harrison Avenue, Suite 1, Boston, MA 02118, USA. Electronic address: sharriman@pyxisoncology.com.
Article em En | MEDLINE | ID: mdl-37352642
PYX-201 is an investigational antibody drug conjugate (ADC) with an engineered, fully human IgG1 antibody, a cleavable chemical linker, and a toxin (Aur0101) with an average drug-antibody ratio (DAR) of âˆ¼ 4. A sensitive and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and fully validated to determine the presence in human plasma, of free payload Aur0101 from PYX-201 to assess drug safety and efficacy. Aur0101 and its deuterated internal standard (IS), Aur0101_d8, were extracted from 25 µL of human plasma using a solid liquid extraction (SLE) method. Chromatographic analysis was carried out on a Waters Acquity UPLC BEH C18 (2.1 mm × 50 mm, 1.7 µm, 130 A) column. Quantitation of free Aur0101 was conducted on a Sciex triple quadrupole mass spectrometer API 6500 + using multiple reaction monitoring (MRM) mode via positive electrospray ionization. The calibration curve was linear over the concentration range of 25.0 to 12,500 pg/mL with correlation coefficient, r2 ≥ 0.9988. The intra-assay %RE was between -4.3% to 14.3% with % CV was ≤ 6.2%. The inter-assay %RE was between -0.2% to 9.5% with % CV was ≤ 6.1%. The average analyte recovery was 89.7% and the average IS recovery was 88.7%. Aur0101 was found to be stable in human plasma and human whole blood under various tested conditions with and without the presence of PYX-201. To our knowledge, this is the first published fully validated assay for free, unconjugated Aur0101 in any matrix, from any species. This assay has been successfully applied to clinical sample analysis to support clinical studies.