Your browser doesn't support javascript.
loading
Agreement Between Virtual Reality Perimetry and Static Automated Perimetry in Various Neuro-Ophthalmological Conditions: A Pilot Study.
Badakere, Akshay; Mir, Amir Ali; Negi, Rahul; Kulkarni, Sampada; Kekunnaya, Ramesh; Sachdeva, Virender.
Afiliação
  • Badakere A; Consultant Ophthalmologist, Child Sight Institute, Jasti V Ramanamma Children's Eye Care Centre, L V Prasad Eye Institute, Hyderabad.
  • Mir AA; Junior Optometrist, Center For Technology Innovation, L V Prasad Eye Institute, Hyderabad, India.
  • Negi R; Junior Optometrist, Center For Technology Innovation, L V Prasad Eye Institute, Hyderabad, India.
  • Kulkarni S; Consultant Ophthalmologist, Child Sight Institute, Jasti V Ramanamma Childrens' Eye Care Centre, L V Prasad Eye Institute, Hyderabad.
  • Kekunnaya R; Head, Child Sight Institute, Jasti V Ramanamma Childrens' Eye Care Centre, L V Prasad Eye Institute, Hyderabad.
  • Sachdeva V; Consultant Ophthalmologist, Child Sight Institute, Nimmagadda Prasad Children's Eye Care Centre, L V Prasad Eye Institute, Vishakhapatnam, India.
Neuroophthalmology ; 47(5-6): 255-261, 2023.
Article em En | MEDLINE | ID: mdl-38130807
ABSTRACT
Our objective was to compare the agreement between virtual reality perimetry (VRP) (order of magnitude, OM) and static automated perimetry (SAP) in various neuro-ophthalmological conditions. We carried out a retrospective analysis of visual field plots of patients with various neuro-ophthalmological conditions who underwent visual field testing using VRP and SAP and between 1 January and 31 May 2022. Two fellowship-trained neuro-ophthalmologists compared the visual field defects observed on both devices. Per cent agreement was used to compare the interpretation of the two examiners on both techniques. The study criteria were met by 160 eyes from 148 patients (mean age 44 years, range 17-74 years). The most common aetiologies were optic atrophy due to various causes, optic neuritis, ischaemic optic neuropathy, and compressive optic neuropathy. Overall, we found good agreement between VRP and SAP for bitemporal (93.8%), hemianopic (90.8%), altitudinal (79.4%), and generalised visual field defects (86.4%). The agreement was acceptable for central/centrocaecal scotomas and not acceptable for enlarged blind spots. Between the two examiners there was good agreement for bitemporal (92.3%), hemianopic (82%), altitudinal (83%), and generalised field defects (76.4%). The results of our study suggest that VRP gives overall good agreement with SAP in various neuro-ophthalmological conditions, especially those likely to produce hemianopic, altitudinal, and generalised visual field defects. This could be useful in various settings; however, future larger studies are needed to explore real-world utilisation.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article