Your browser doesn't support javascript.
loading
Measurement of perfluoroalkyl substances in drinking water sources by DGT sampler with a novel fluorinated graphite binding gel.
Dong, Fan; Ge, Fan; Zhao, Xinting; Sun, Daming; Ren, Suyu; Wang, Yan; Tan, Feng.
Afiliação
  • Dong F; Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China.
  • Ge F; Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China.
  • Zhao X; Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China.
  • Sun D; Dalian Hydrological Bureau of Liaoning Province, Dalian 116023, China.
  • Ren S; School of Environmental and Material Engineering, Yantai University, Yan Tai 264005, China.
  • Wang Y; Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China.
  • Tan F; Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China. Electronic address: tanf@dlut.edu.cn.
Sci Total Environ ; 912: 169658, 2024 Feb 20.
Article em En | MEDLINE | ID: mdl-38159764
ABSTRACT
Extensive use of per- and polyfluoroalkyl substances (PFASs) has resulted in their widespread presence in natural waters. Concern for public health requires reliable measurement methods for determining their distribution and risks. Here, a sampling method based on diffusive gradients in thin films (DGT) was developed for measuring PFASs in drinking water sources. Fluorinated graphite (FG) particles were used to prepare the DGT binding gel for selective enrichment of trace PFASs in an aqueous environment. The FG-DGT method did not show sensitivity to relevant environmental parameters including pH (5.0-9.0), ionic strength (0.001-0.5 M), or DOM concentration (0-30 mg/L). The FG-DGT had enough capacity for deployment of up to four months. Six traditional and emerging PFASs including PFOS, PFOA, PFHpA, PFHxS, PFNA, and 62 FTSA at the ng/L level were detected in two major reservoirs serving as public drinking water sources by FG-DGT method coupled with liquid chromatography tandem mass spectrometry (LC-MS/MS). PFOA appeared at the highest observed concentrations in the drinking water sources. The research demonstrates that FG-DGT is an effective and efficient tool for monitoring PFASs in drinking water.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Água Potável / Fluorocarbonos / Grafite Idioma: En Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Água Potável / Fluorocarbonos / Grafite Idioma: En Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China