Your browser doesn't support javascript.
loading
Effect of variable left ventricular ejection fraction assessed by equilibrium radionuclide angiocardiography using different software packages on the diagnosis of cardiotoxicity in patients with cancer.
Suero-Abreu, Giselle Alexandra; Lim, Phillip; Raza, Anoshia; Tysarowski, Maciej; Mehta, Khyati; Kortbawi, Michael; Feldman, Stephanie; Waller, Alfonso H.
Afiliação
  • Suero-Abreu GA; Division of Cardiology, Massachusetts General Hospital, Boston, MA, USA.
  • Lim P; Department of Medicine, Rutgers New Jersey Medical School, Newark, NJ, USA.
  • Raza A; Division of Cardiology, Rutgers New Jersey Medical School, Newark, NJ, USA.
  • Tysarowski M; Division of Cardiology, Hartford Hospital, Hartford, CT, USA.
  • Mehta K; Department of Medicine, Rutgers New Jersey Medical School, Newark, NJ, USA.
  • Kortbawi M; Department of Nuclear Medicine, University Hospital, Newark, NJ, USA.
  • Feldman S; Division of Cardiology, Department of Medicine, Weill Cornell Medical College, New York, NY, USA.
  • Waller AH; Department of Medicine, Rutgers New Jersey Medical School, Newark, NJ, USA; Division of Cardiology, Rutgers New Jersey Medical School, Newark, NJ, USA; Department of Nuclear Medicine, University Hospital, Newark, NJ, USA. Electronic address: ahw22@njms.rutgers.edu.
J Nucl Cardiol ; 31: 101782, 2024 Jan.
Article em En | MEDLINE | ID: mdl-38216410
ABSTRACT

BACKGROUND:

The equilibrium radionuclide angiocardiography (ERNA) scan is an established imaging modality for assessing left ventricular ejection fraction (LVEF) in oncology patients. This study aimed to explore the interchangeability of two commercially available software packages (MIM and JS) for LVEF measurement for a cancer-therapy-related cardiac dysfunction (CTRCD) diagnosis.

METHODS:

This is a single-center retrospective study among 322 patients who underwent ERNA scans. A total of 582 scans were re-processed using MIM and JS for cross-sectional and longitudinal LVEF measurements.

RESULTS:

The median LVEF for MIM and JS were 56% and 66%, respectively (P < 0.001). LVEF processed by JS was 9.91% higher than by MIM. In 87 patients with longitudinal ERNA scans, serial studies processed by MIM were classified as having CTRCD in a higher proportion than serial studies processed by JS (26.4% vs 11.4%, P = 0.020). There were no significant differences in intra- or inter-observer LVEF measurement variability (R = 0.99, P < 0.001).

CONCLUSIONS:

Software packages for processing ERNA studies are not interchangeable; thus, reports of ERNA studies should include details on the post-processing software. Serial ERNA studies should be processed on the same software when feasible to avoid discrepancies in the diagnosis and management of CTRCD.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Disfunção Ventricular Esquerda / Neoplasias Idioma: En Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Disfunção Ventricular Esquerda / Neoplasias Idioma: En Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos