Your browser doesn't support javascript.
loading
Effective extraction and determination of 24 quinolones in water and egg samples using a novel magnetic covalent organic framework combined with UPLC-MS/MS.
Li, Na; Liang, Mengnan; Zhang, Hao; Hua, Zhongxia; Ma, Ling; Qi, Yanyu; Wang, Ke.
Afiliação
  • Li N; College of Chemistry and Materials Science, Hebei Normal University Shijiazhuang 050023 China wkecdc@163.com hbsdqyy@hebtu.edu.cn.
  • Liang M; College of Chemistry and Materials Science, Hebei Normal University Shijiazhuang 050023 China wkecdc@163.com hbsdqyy@hebtu.edu.cn.
  • Zhang H; College of Chemistry and Materials Science, Hebei Normal University Shijiazhuang 050023 China wkecdc@163.com hbsdqyy@hebtu.edu.cn.
  • Hua Z; Shijiazhuang Center for Disease Control and Prevention Shijiazhuang 050011 China mamalin001@163.com.
  • Ma L; Shijiazhuang Technology Innovation Center for Chemical Poison Detection and Risk Early Warning Shijiazhuang 050011 China.
  • Qi Y; Shijiazhuang Center for Disease Control and Prevention Shijiazhuang 050011 China mamalin001@163.com.
  • Wang K; Shijiazhuang Technology Innovation Center for Chemical Poison Detection and Risk Early Warning Shijiazhuang 050011 China.
RSC Adv ; 14(12): 8303-8312, 2024 Mar 06.
Article em En | MEDLINE | ID: mdl-38487520
ABSTRACT
The excessive use of quinolones (QNs) has seriously threatened human health. In this study, a novel functionalized magnetic covalent organic framework Fe3O4@SiO2@Ah-COF was fabricated with biphenyl-3,3',5,5'-tetracarbaldehyde and hydrazine hydrate (85%) as monomers and was used as a magnetic solid-phase extraction (MSPE) absorbent for the determination of 24 QNs in water and egg samples through ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The extraction parameters of MSPE were optimized, including pH, adsorbent dosage, adsorption time, and eluent type. An effective and rapid detection method was then established, which showed good linearity (R2 ≥ 0.9990), low limits of detection (0.003-0.036 µg L-1) and low limits of quantitation (0.008-0.110 µg L-1) for QNs. The good recoveries of 24 QNs in water and egg samples were in the range of 70.3-106.1% and 70.4-119.7%, respectively, with relative standard deviations lower than 10% (n = 5). As a result, Fe3O4@SiO2@Ah-COF is a promising magnetic adsorbent, and the established method was successfully applied for the determination of 24 QNs in water and egg samples.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article