Your browser doesn't support javascript.
loading
Pitfalls and possibilities of using Root SedLine for continuous assessment of EEG waveform-based metrics in intensive care research.
Bögli, Stefan Yu; Cherchi, Marina Sandra; Olakorede, Ihsane; Lavinio, Andrea; Beqiri, Erta; Moyer, Ethan; Moberg, Dick; Smielewski, Peter.
Afiliação
  • Bögli SY; Brain Physics Laboratory, Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge, United Kingdom.
  • Cherchi MS; Brain Physics Laboratory, Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge, United Kingdom.
  • Olakorede I; Department of Critical Care, Marqués de Valdecilla University Hospital, and Biomedical Research Institute (IDIVAL), Santander, Cantabria, Spain.
  • Lavinio A; Brain Physics Laboratory, Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge, United Kingdom.
  • Beqiri E; Division of Anaesthesia, Addenbrooke's Hospital, University of Cambridge, Cambridge, United Kingdom.
  • Moyer E; Brain Physics Laboratory, Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge, United Kingdom.
  • Moberg D; Moberg Analytics Ltd, Philadelphia, PA, United States of America.
  • Smielewski P; Moberg Analytics Ltd, Philadelphia, PA, United States of America.
Physiol Meas ; 45(5)2024 May 30.
Article em En | MEDLINE | ID: mdl-38697208
ABSTRACT
Objective.The Root SedLine device is used for continuous electroencephalography (cEEG)-based sedation monitoring in intensive care patients. The cEEG traces can be collected for further processing and calculation of relevant metrics not already provided. Depending on the device settings during acquisition, the acquired traces may be distorted by max/min value cropping or high digitization errors. We aimed to systematically assess the impact of these distortions on metrics used for clinical research in the field of neuromonitoring.Approach.A 16 h cEEG acquired using the Root SedLine device at the optimal screen settings was analyzed. Cropping and digitization error effects were simulated by consecutive reduction of the maximum cEEG amplitude by 2µV or by reducing the vertical resolution. Metrics were calculated within ICM+ using minute-by-minute data, including the total power, alpha delta ratio (ADR), and 95% spectral edge frequency. Data were analyzed by creating violin- or box-plots.Main Results.Cropping led to a continuous reduction in total and band power, leading to corresponding changes in variability thereof. The relative power and ADR were less affected. Changes in resolution led to relevant changes. While the total power and power of low frequencies were rather stable, the power of higher frequencies increased with reducing resolution.Significance.Care must be taken when acquiring and analyzing cEEG waveforms from Root SedLine for clinical research. To retrieve good quality metrics, the screen settings must be kept within the central vertical scale, while pre-processing techniques must be applied to exclude unacceptable periods.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cuidados Críticos / Eletroencefalografia Idioma: En Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cuidados Críticos / Eletroencefalografia Idioma: En Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Reino Unido