Your browser doesn't support javascript.
loading
Bearing-Related Complications of Total Hip Arthroplasty Using Fourth-Generation Ceramic-On-Ceramic Articulations: Does Articular Noise Increase Over Time?
Park, Chan-Woo; Jeong, Sang-Jin; Cho, Kyungjun; Kim, Si Yeon; Lim, Seung-Jae; Park, Youn-Soo.
Afiliação
  • Park CW; Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
  • Jeong SJ; Department of Orthopedic Surgery, Myongji hospital, Hanyang University School of Medicine, Goyang, South Korea.
  • Cho K; Department of Orthopedic Surgery, Osan Hankook Hospital, Osan, South Korea.
  • Kim SY; Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
  • Lim SJ; Department of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
  • Park YS; Department of Orthopedic Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, South Korea.
J Arthroplasty ; 2024 May 10.
Article em En | MEDLINE | ID: mdl-38735552
ABSTRACT

BACKGROUND:

We previously reported the mean 6-year outcomes of total hip arthroplasty (THA) using fourth-generation ceramic-on-ceramic (CoC) articulations. With extended observations, this study aimed to report the mean 12-year outcomes focusing on bearing-related complications of CoC THA.

METHODS:

We reviewed primary CoC THAs performed between May 2009 and April 2012 at a single institution. Of the 831 hips (739 patients), 716 hips (635 patients) that satisfied a minimum 10-year follow-up were included. The mean age at operation was 54 years (range, 16 to 83). The occurrence of bearing-specific complications, including ceramic fractures and noise generation, was evaluated. The mean follow-up duration was 12 years (range, 10 to 14).

RESULTS:

A total of 2 (0.3%) ceramic liner fractures occurred, as previously reported. No additional ceramic fractures were observed during the extended follow-up period. However, the cumulative incidence of audible noise increased from 6.4 (48 of 749) to 8.2% (59 of 716). Of the 59 hips with noise, 26 (44.1%) developed noise within 1 year, whereas 13 (22.0%) presented with noise more than 5 years after THA. The noise was described as clicking in 35 hips (4.9%) and as squeaking in 24 hips (3.4%). No revision surgeries were performed for noise, except in 2 cases of concomitant liner fractures. The implant survivorship free of any revision was 98.1% at 12 years.

CONCLUSIONS:

No additional ceramic fractures were identified in this extension study at a minimum follow-up of 10 years. However, the prevalence of articular noise has increased from 6.4 to 8.2% since the previous report. Possible late-onset noise should be considered when performing CoC THA in younger patients.