Your browser doesn't support javascript.
loading
Hybrid spectral CT system with clinical rapid kVp-switching x-ray tube and dual-layer detector for improved iodine quantification.
Sandvold, Olivia F; Proksa, Roland; Daerr, Heiner; Perkins, Amy E; Brown, Kevin M; Shapira, Nadav; Koehler, Thomas; Stayman, J Webster; Gang, Grace J; Manjeshwar, Ravindra M; Noël, Peter B.
Afiliação
  • Sandvold OF; Department of Radiology, Perelman School of Medicine, Philadelphia, USA 19104.
  • Proksa R; Department of Bioengineering, University of Pennsylvania, Philadelphia, USA 19104.
  • Daerr H; Department of Radiology, Perelman School of Medicine, Philadelphia, USA 19104.
  • Perkins AE; Philips Innovative Technologies, Hamburg, Germany 22335.
  • Brown KM; Philips Healthcare, Cleveland, USA 44122.
  • Shapira N; Philips Healthcare, Cleveland, USA 44122.
  • Koehler T; Department of Radiology, Perelman School of Medicine, Philadelphia, USA 19104.
  • Stayman JW; Philips Innovative Technologies, Hamburg, Germany 22335.
  • Gang GJ; Johns Hopkins University, Baltimore, USA 21218.
  • Manjeshwar RM; Department of Radiology, Perelman School of Medicine, Philadelphia, USA 19104.
  • Noël PB; Philips Healthcare, Cleveland, USA 44122.
Article em En | MEDLINE | ID: mdl-38803525
ABSTRACT
Spectral computed tomography (CT) is a powerful diagnostic tool offering quantitative material decomposition results that enhance clinical imaging by providing physiologic and functional insights. Iodine, a widely used contrast agent, improves visualization in various clinical contexts. However, accurately detecting low-concentration iodine presents challenges in spectral CT systems, particularly crucial for conditions like pancreatic cancer assessment. In this study, we present preliminary results from our hybrid spectral CT instrumentation which includes clinical-grade hardware (rapid kVp-switching x-ray tube, dual-layer detector). This combination expands spectral datasets from two to four channels, wherein we hypothesize improved quantification accuracy for low-dose and low-iodine concentration cases. We modulate the system duty cycle to evaluate its impact on quantification noise and bias. We evaluate iodine quantification performance by comparing two hybrid weighting strategies alongside rapid kVp-switching. This evaluation is performed with a polyamide phantom containing seven iodine inserts ranging from 0.5 to 20 mg/mL. In comparison to alternative methodologies, the maximum separation configuration, incorporating data from both the 80 kVp, low photon energy detector layer and the 140 kVp, high photon energy detector layer produces spectral images containing low quantitative noise and bias. This study presents initial evaluations on a hybrid spectral CT system, leveraging clinical hardware to demonstrate the potential for enhanced precision and sensitivity in spectral imaging. This research holds promise for advancing spectral CT imaging performance across diverse clinical scenarios.