Your browser doesn't support javascript.
loading
Value of fractional-order calculus (FROC) model diffusion-weighted imaging combined with simultaneous multi-slice (SMS) acceleration technology for evaluating benign and malignant breast lesions.
Wang, Fei; Sun, Yi-Nan; Zhang, Bao-Ti; Yang, Qing; He, An-Dong; Xu, Wang-Yan; Liu, Jun; Liu, Meng-Xiao; Li, Xiao-Hu; Yu, Yong-Qiang; Zhu, Juan.
Afiliação
  • Wang F; Department of Radiology, The First Affiliated Hospital of Anhui Medical University, No.218, Jixi Road, Hefei, 230032, China.
  • Sun YN; Department of Radiology, Anqing Municipal Hospital, No.352, Renmin Road, Anqing, 246003, China.
  • Zhang BT; Department of Radiology, Anqing Municipal Hospital, No.352, Renmin Road, Anqing, 246003, China.
  • Yang Q; Department of Radiology, Anqing Municipal Hospital, No.352, Renmin Road, Anqing, 246003, China.
  • He AD; Department of Radiology, Anqing Municipal Hospital, No.352, Renmin Road, Anqing, 246003, China.
  • Xu WY; Department of Radiology, Anqing Municipal Hospital, No.352, Renmin Road, Anqing, 246003, China.
  • Liu J; Department of Radiology, Anqing Municipal Hospital, No.352, Renmin Road, Anqing, 246003, China.
  • Liu MX; Department of Radiology, Anqing Municipal Hospital, No.352, Renmin Road, Anqing, 246003, China.
  • Li XH; MR Research & Marketing Department, Siemens Healthineers Co., Ltd, No.278, Zhouzugong Road, Shanghai, 201318, China.
  • Yu YQ; Department of Radiology, The First Affiliated Hospital of Anhui Medical University, No.218, Jixi Road, Hefei, 230032, China.
  • Zhu J; Department of Radiology, The First Affiliated Hospital of Anhui Medical University, No.218, Jixi Road, Hefei, 230032, China. cjr.yuyongqiang@vip.163.com.
BMC Med Imaging ; 24(1): 190, 2024 Jul 29.
Article em En | MEDLINE | ID: mdl-39075336
ABSTRACT

BACKGROUND:

This study explores the diagnostic value of combining fractional-order calculus (FROC) diffusion-weighted model with simultaneous multi-slice (SMS) acceleration technology in distinguishing benign and malignant breast lesions.

METHODS:

178 lesions (73 benign, 105 malignant) underwent magnetic resonance imaging with diffusion-weighted imaging using multiple b-values (14 b-values, highest 3000 s/mm2). Independent samples t-test or Mann-Whitney U test compared image quality scores, FROC model parameters (D,, ), and ADC values between two groups. Multivariate logistic regression analysis identified independent variables and constructed nomograms. Model discrimination ability was assessed with receiver operating characteristic (ROC) curve and calibration chart. Spearman correlation analysis and Bland-Altman plot evaluated parameter correlation and consistency.

RESULTS:

Malignant lesions exhibited lower D, and ADC values than benign lesions (P < 0.05), with higher values (P < 0.05). In SSEPI-DWI and SMS-SSEPI-DWI sequences, the AUC and diagnostic accuracy of D value are maximal, with D value demonstrating the highest diagnostic sensitivity, while value exhibits the highest specificity. The D and combined model had the highest AUC and accuracy. D and ADC values showed high correlation between sequences, and moderate. Bland-Altman plot demonstrated unbiased parameter values.

CONCLUSION:

SMS-SSEPI-DWI FROC model provides good image quality and lesion characteristic values within an acceptable time. It shows consistent diagnostic performance compared to SSEPI-DWI, particularly in D and values, and significantly reduces scanning time.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Imagem de Difusão por Ressonância Magnética Idioma: En Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Imagem de Difusão por Ressonância Magnética Idioma: En Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China