Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 193
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38967206

ABSTRACT

BACKGROUND: The Alterra adaptive prestent is a novel self-expanding device designed to provide a landing zone for the 29 mm SAPIEN 3 valve to treat pulmonary regurgitation in patients with a right ventricular outflow tract that is too large for a balloon expandable valve alone. The mechanism of fixation for the Alterra prestent is radial force from the self-expanding stent frame, combined with a unique set of flared "tines" that protrude from both ends of the stent. AIMS, METHODS, AND RESULTS: In this report, we describe 6 patients who underwent uncomplicated transcatheter pulmonary valve replacement with an Alterra adaptive prestent and SAPIEN 3 valve and had surveillance chest computed tomography (CT) scans performed 1 day to 21 months after implant. In each patient, the CT scan demonstrated extravascular extension of a portion of the Alterra prestent, without clinical sequelae, but with extension into the ascending aorta in 1 patient and contact with the ascending aorta, left pulmonary vein, or left atrial appendage in 3 others. CONCLUSIONS: Surveillance CT imaging shows that the Alterra prestent can perforate the pulmonary artery and/or right ventricle. Although no sequelae were seen in these patients, prestent perforation has the potential to be clinically important. Implanters should be aware of this finding and its potential implications. As experience with the Alterra prestent grows, it will be important to further define the risk factors, incidence, and implications of this phenomenon.

2.
Eur Heart J ; 44(34): 3278-3291, 2023 09 07.
Article in English | MEDLINE | ID: mdl-37592821

ABSTRACT

BACKGROUND AND AIMS: For patients with congenitally corrected transposition of the great arteries (ccTGA), factors associated with progression to end-stage congestive heart failure (CHF) remain largely unclear. METHODS: This multicentre, retrospective cohort study included adults with ccTGA seen at a congenital heart disease centre. Clinical data from initial and most recent visits were obtained. The composite primary outcome was mechanical circulatory support, heart transplantation, or death. RESULTS: From 558 patients (48% female, age at first visit 36 ± 14.2 years, median follow-up 8.7 years), the event rate of the primary outcome was 15.4 per 1000 person-years (11 mechanical circulatory support implantations, 12 transplantations, and 52 deaths). Patients experiencing the primary outcome were older and more likely to have a history of atrial arrhythmia. The primary outcome was highest in those with both moderate/severe right ventricular (RV) dysfunction and tricuspid regurgitation (n = 110, 31 events) and uncommon in those with mild/less RV dysfunction and tricuspid regurgitation (n = 181, 13 events, P < .001). Outcomes were not different based on anatomic complexity and history of tricuspid valve surgery or of subpulmonic obstruction. New CHF admission or ventricular arrhythmia was associated with the primary outcome. Individuals who underwent childhood surgery had more adverse outcomes than age- and sex-matched controls. Multivariable Cox regression analysis identified older age, prior CHF admission, and severe RV dysfunction as independent predictors for the primary outcome. CONCLUSIONS: Patients with ccTGA have variable deterioration to end-stage heart failure or death over time, commonly between their fifth and sixth decades. Predictors include arrhythmic and CHF events and severe RV dysfunction but not anatomy or need for tricuspid valve surgery.


Subject(s)
Heart Failure , Transposition of Great Vessels , Tricuspid Valve Insufficiency , Ventricular Dysfunction, Right , Adult , Humans , Female , Child , Young Adult , Middle Aged , Male , Congenitally Corrected Transposition of the Great Arteries , Retrospective Studies , Transposition of Great Vessels/complications , Transposition of Great Vessels/surgery , Tricuspid Valve Insufficiency/complications , Ventricular Dysfunction, Right/complications , Heart Failure/complications
3.
Catheter Cardiovasc Interv ; 101(1): 135-139, 2023 01.
Article in English | MEDLINE | ID: mdl-36434791

ABSTRACT

The Harmony™ Transcatheter Pulmonary Valve (Medtronic) was recently approved by the Food and Drug Administration for transcatheter pulmonary valve replacement in native right ventricular outflow tracts. Despite this milestone, some patients have main pulmonary arteries that are severely dilated and continue to require surgical pulmonary valve replacement. The hybrid approach combines surgical creation of a landing zone, transcatheter valve deployment, and suture stabilization of the implanted valve. In this case series, we report the first use of a hybrid approach for Harmony™ transcatheter pulmonary valve replacement. Two cases are reported with varying approaches for surgical creation of a landing zone followed by successful placement of a Harmony™ valve.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Humans , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/surgery , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/surgery , Heart Valve Prosthesis Implantation/adverse effects , Treatment Outcome , Cardiac Catheterization , Prosthesis Design
4.
Article in English | MEDLINE | ID: mdl-36842803

ABSTRACT

The field of adult congenital heart disease has changed greatly over the past sixty years. As patients are now surviving longer into adulthood due to various improvements in surgical technique and medical technology, the demographic of patients with congenital heart disease (CHD) has changed, such that there are now more adults with CHD than there are children with CHD. This older and more medically complex population needs more interventions to treat residual defects or sequelae of their initial surgeries, and many of these patients are now deemed high risk for surgery. When the surgical risk becomes too great, either due to patient complexity, surgical complexity, or both, then transcatheter procedures may have a role in either mitigating or avoiding the risk altogether.


Subject(s)
Heart Defects, Congenital , Child , Adult , Humans , Heart Defects, Congenital/surgery , Disease Progression , Catheters
5.
Curr Opin Cardiol ; 37(1): 123-129, 2022 Jan 01.
Article in English | MEDLINE | ID: mdl-34857720

ABSTRACT

PURPOSE OF REVIEW: Adult congenital heart disease patients with systemic right ventricle comprise a distinctly clinically challenging group of patients with increased morbidity and mortality. This article aims to review the different subgroups, most common complications and different treatment strategies. RECENT FINDINGS: Most commons long-term complications include heart failure and arrhythmias. Heart failure medical therapy treatments include several new agents, which show promise in systemic right ventricle patients. In addition, interventional therapies to mitigate atrioventricular valve regurgitation, baffle/conduit stenosis are discussed. Furthermore, several electrophysiological approaches to manage tachyarrhythmias as well as bradycardias are discussed. There is ongoing excitement on the new medical as well as interventional therapies that could provide benefit in additional to standard goal-directed medical therapy. SUMMARY: There is an array of medications as well as interventions aimed to treat patients with systemic right ventricle with limited benefits. A multidisciplinary approach with a prudent combination of such therapies to maximize benefit is imperative. This article reviews the data supporting such therapies.


Subject(s)
Heart Defects, Congenital , Heart Failure , Adult , Arrhythmias, Cardiac , Heart Defects, Congenital/complications , Heart Defects, Congenital/therapy , Heart Failure/etiology , Heart Failure/therapy , Heart Ventricles , Humans
6.
Catheter Cardiovasc Interv ; 100(3): 399-403, 2022 09.
Article in English | MEDLINE | ID: mdl-35819275

ABSTRACT

Transcatheter correction of a superior sinus venosus defect and partial anomalous pulmonary venous connection with covered stents is a feasible alternative to surgical repair in select patients. Commercially available balloon-expandable covered stents may be of inadequate length to treat some patients. This may require multiple stents to be placed, which increases the risk of stent migration or embolization. A modification of this technique utilizing two interdigitating covered stents secured together with sutures is described, allowing for increased stability of a long stent complex. One failed case and a second successful case are presented.


Subject(s)
Heart Septal Defects, Atrial , Pulmonary Veins , Heart Septal Defects, Atrial/surgery , Heart Septal Defects, Atrial/therapy , Humans , Pulmonary Veins/abnormalities , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Stents , Sutures , Treatment Outcome
7.
J Cardiothorac Vasc Anesth ; 36(3): 707-712, 2022 03.
Article in English | MEDLINE | ID: mdl-34175203

ABSTRACT

OBJECTIVE: To determine if patients with congenital heart disease are undergoing laparoscopic surgery requiring abdominal insufflation and to compare the outcomes of these procedures with those who underwent an open surgical approach. DESIGN, SETTING, PARTICIPANTS: This was a retrospective study using the National Inpatient Sample from 2006 to 2014. Individuals with congenital heart disease who underwent at least one of six selected surgical procedures (laparoscopic or open) were included in the study. Subgroup analysis was performed on patients with Fontan palliation. MEASUREMENTS AND MAIN RESULTS: The primary outcome was to determine the frequency with which congenital heart disease patients undergo laparoscopic surgery requiring abdominal insufflation compared with open surgery. Secondary outcomes included all-cause in-hospital mortality and in-hospital length of stay. Of the 5,527 patients included, nearly half underwent laparoscopic surgery (46.3%), and 128 (2.3%) had single-ventricle circulation. All-cause mortality was significantly higher for those who underwent open surgery compared with the laparoscopic approach (3.6% v 0.9%; odds ratio [OR], 4.0 [2.6-6.3]; p < 0.0001). Subgroup analysis of patients with Fontal palliation older than five years showed 30 (42%) underwent laparoscopic surgery and there was no mortality difference between the laparoscopic and open approaches (OR, 1.4 [0.2-21.3], p = 0.8). Length of stay was significantly shorter for patients undergoing laparoscopic compared with open surgery (median three days [interquartile range, two-five] v six days [three-13], p < 0.0001). CONCLUSIONS: Individuals with congenital heart disease are being offered laparoscopic surgery that requires abdominal insufflation. All-cause mortality and length of stay were higher for patients who underwent open surgical operations.


Subject(s)
Heart Defects, Congenital , Insufflation , Laparoscopy , Heart Defects, Congenital/surgery , Hospital Mortality , Humans , Length of Stay , Postoperative Complications/surgery , Retrospective Studies , Treatment Outcome
8.
Pediatr Cardiol ; 43(4): 894-902, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34894280

ABSTRACT

Guidelines for management of Melody transcatheter pulmonary valve (TPV) infective endocarditis (IE) are lacking. We aimed to identify factors associated with surgical valve removal versus antimicrobial therapy in Melody TPV IE. Multicenter retrospective analysis of all patients receiving Melody TPV from 10/2010 to 3/2019 was performed to identify cases of IE. Surgical explants versus non-surgical cases were compared. Of the 663 Melody TPV implants, there were 66 cases of IE in 59 patients (59/663, 8.8%). 39/66 (59%) were treated with IV antimicrobials and 27/66(41%) underwent valve explantation. 26/59 patients (44%) were treated medically without explantation or recurrence with average follow-up time of 3.5 years (range:1-9). 32% of Streptococcus cases, 53% of MSSA, and all MRSA cases were explanted. 2 of the 4 deaths had MSSA. CART analysis demonstrated two important parameters associated with explantation: a peak echo gradient ≥ 47 mmHg at IE diagnosis(OR 10.6, p < 0.001) and a peak echo gradient increase of > 24 mmHg compared to baseline (OR 6.7, p = 0.01). Rates of explantation varied by institution (27 to 64%). In our multicenter experience, 44% of patients with Melody IE were successfully medically treated without valve explantation or recurrence. The degree of valve stenosis at time of IE diagnosis was strongly associated with explantation. Rates of explantation varied significantly among the institutions.


Subject(s)
Endocarditis, Bacterial , Endocarditis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Cardiac Catheterization/adverse effects , Endocarditis/etiology , Endocarditis/surgery , Endocarditis, Bacterial/drug therapy , Endocarditis, Bacterial/surgery , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Humans , Prosthesis Design , Pulmonary Valve/surgery , Pulmonary Valve Insufficiency/surgery , Retrospective Studies , Treatment Outcome
9.
Eur Heart J ; 42(19): 1858-1865, 2021 05 14.
Article in English | MEDLINE | ID: mdl-33313664

ABSTRACT

We are witnessing an unparalleled pandemic caused by the novel Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) associated with coronavirus disease 2019 (COVID-19). Current data show that SARS-CoV-2 results in mild flu-like symptoms in the majority of healthy and young patients affected. Nevertheless, the severity of COVID-19 respiratory syndrome and the risk of adverse or catastrophic outcomes are increased in patients with pre-existing cardiovascular disease. Patients with adult congenital heart disease (ACHD)-by definition-have underlying cardiovascular disease. Many patients with ACHD are also afflicted with residual haemodynamic lesions such as valve dysfunction, diminished ventricular function, arrhythmias or cyanosis, have extracardiac comorbidities, and face additional challenges regarding pregnancy. Currently, there are emerging data of the effect of COVID-19 on ACHD patients, but many aspects, especially risk stratification and treatment considerations, remain unclear. In this article, we aim to discuss the broad impact of COVID-19 on ACHD patients, focusing specifically on pathophysiology, risk stratification for work, self-isolation, hospitalization, impact on pregnancy, psychosocial health, and longer-term implications for the provision of ACHD care.


Subject(s)
COVID-19 , Cardiovascular Diseases , Heart Defects, Congenital , Adult , Heart Defects, Congenital/complications , Heart Defects, Congenital/epidemiology , Heart Defects, Congenital/therapy , Humans , Pandemics , SARS-CoV-2
10.
Cardiol Young ; 32(4): 597-605, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34294186

ABSTRACT

The Patient Registry for Adolescents and Adults with Stable Fontan Circulation aims to describe a contemporary cohort of Fontan patients who could be eligible for a clinical trial investigating macitentan, an endothelin receptor antagonist. This international, non-interventional, multicentre, cross-sectional, observational registry enrolled patients with "stable" Fontan circulation ≥10 years following extra-cardiac conduit or lateral tunnel procedure. Main exclusion criteria were NYHA functional class IV, reoperation of Fontan circulation, or signs of disease worsening. Patient characteristics at enrolment are described; available data were collected during a single registration visit. Of the 266 screened patients, 254 were included in this analysis. At enrolment, median (interquartile range) age was 24 (20;30) years, 37%/63% of patients were from the USA/Europe, 54% were male, 54%/47% had undergone extra-cardiac conduit/lateral tunnel procedures, and 95% were in NYHA functional class I or II. History of arrhythmia was more common in older patients and patients with lateral tunnel; overall prevalence was 19%. Most laboratory values were within the normal range but mean creatinine clearance was abnormally low (87.7 ml/min). Angiotensin-converting enzyme inhibitors were used by 48% of patients and their use was associated with creatinine clearance <90 ml/min (p = 0.007), as was Fontan completion at an older age (p = 0.007). 53.4% of patients had clinical characteristics that could potentially meet an endothelin receptor antagonist trial's eligibility criteria. The PREpArE-Fontan registry describes a cohort of patients who could potentially participate in an endothelin receptor antagonist trial and identified early subtle signs of Fontan failure, even in "stable" patients.


Subject(s)
Fontan Procedure , Heart Defects, Congenital , Adolescent , Adult , Aged , Creatinine , Cross-Sectional Studies , Endothelin Receptor Antagonists , Female , Fontan Procedure/adverse effects , Heart Defects, Congenital/diagnosis , Humans , Male , Registries , Retrospective Studies , Treatment Outcome
11.
Catheter Cardiovasc Interv ; 98(4): 810-814, 2021 10.
Article in English | MEDLINE | ID: mdl-33856112

ABSTRACT

Cor triatriatum sinister (CTS) is a rare congenital cardiac anomaly representing <0.1% of all congenital cardiac malformations. It is characterized by the presence of a left atrial (LA) membrane that leads to left ventricular inflow obstruction. Uncorrected, obstructed CTS may have significant sequelae such as pulmonary hypertension or arrhythmias. Transcatheter balloon decompression has been described as a successful alternative to surgical resection of the obstructing membrane. Our review of the literature revealed no reported cases utilizing radiofrequency (RF) energy to perforate the CTS membrane prior to balloon decompression. This manuscript describes two patients with CTS who were treated successfully with a transcatheter technique using RF energy to perforate the obstructing membrane prior to balloon angioplasty and decompression of the LA.


Subject(s)
Cor Triatriatum , Heart Defects, Congenital , Cor Triatriatum/complications , Cor Triatriatum/diagnostic imaging , Cor Triatriatum/surgery , Decompression , Heart Ventricles , Humans , Treatment Outcome
12.
BMC Cardiovasc Disord ; 21(1): 592, 2021 12 09.
Article in English | MEDLINE | ID: mdl-34886795

ABSTRACT

BACKGROUND: COVID-19 and Fontan physiology have each been associated with an elevated risk of venous thromboembolism (VTE), however little is known about the risks and potential consequences of having both. CASE PRESENTATION: A 51 year old male with tricuspid atresia status post Fontan and extracardiac Glenn shunt, atrial flutter, and sinus sick syndrome presented with phlegmasia cerulea dolens (PCD) of the left lower extremity in spite of supratherapeutic INR in the context of symptomatic COVID-10 pneumonia. He was treated with single session, catheter directed mechanical thrombectomy that was well-tolerated. CONCLUSIONS: This report of acute PCD despite therapeutic anticoagulation with a Vitamin K antagonist, managed with emergent mechanical thrombectomy, calls to attention the importance of altered flow dynamics in COVID positive patients with Fontan circulation that may compound these independent risk factors for developing deep venous thrombosis with the potential for even higher morbidity.


Subject(s)
COVID-19 , Fontan Procedure , Gangrene , Mechanical Thrombolysis , Postoperative Complications , Thrombophlebitis , Tricuspid Atresia , Warfarin/therapeutic use , Amputation, Surgical/methods , Atrial Flutter/drug therapy , Atrial Flutter/etiology , COVID-19/blood , COVID-19/complications , COVID-19/therapy , Fontan Procedure/adverse effects , Fontan Procedure/methods , Gangrene/etiology , Gangrene/surgery , Heart Defects, Congenital/surgery , Humans , Image Processing, Computer-Assisted/methods , Lower Extremity/blood supply , Lower Extremity/pathology , Lower Extremity/surgery , Male , Mechanical Thrombolysis/adverse effects , Mechanical Thrombolysis/methods , Middle Aged , Phlebography/methods , Postoperative Complications/diagnosis , Postoperative Complications/physiopathology , Postoperative Complications/surgery , Sick Sinus Syndrome/diagnosis , Sick Sinus Syndrome/etiology , Thrombophlebitis/diagnosis , Thrombophlebitis/etiology , Thrombophlebitis/surgery , Tomography, X-Ray Computed/methods , Treatment Outcome , Tricuspid Atresia/etiology , Tricuspid Atresia/surgery
13.
Catheter Cardiovasc Interv ; 96(2): 384-388, 2020 08.
Article in English | MEDLINE | ID: mdl-32073720

ABSTRACT

Congenital heart disease patients, specifically with unbalanced atrioventricular septal defects and common atrioventricular valves requiring single ventricle palliation, have substantial morbidity and mortality. Atrioventricular valve regurgitation (AVVR) is associated with poor outcomes in single ventricle patients, and many of them require surgical treatment of AVVR in their lifetimes. We describe a unique case of transcatheter edge-to-edge valve repair using the MitraClip system (Abbott, Chicago, IL) in a single ventricle patient with severe common AVVR.


Subject(s)
Cardiac Surgical Procedures , Double Outlet Right Ventricle/surgery , Heart Septal Defects/complications , Heart Septal Defects/surgery , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation , Heart Valves/surgery , Heterotaxy Syndrome/surgery , Adult , Cardiac Surgical Procedures/adverse effects , Double Outlet Right Ventricle/diagnostic imaging , Double Outlet Right Ventricle/physiopathology , Heart Septal Defects/physiopathology , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/etiology , Heart Valve Diseases/physiopathology , Heart Valve Prosthesis Implantation/instrumentation , Heart Valves/diagnostic imaging , Heart Valves/physiopathology , Heterotaxy Syndrome/diagnostic imaging , Heterotaxy Syndrome/physiopathology , Humans , Male , Recovery of Function , Treatment Outcome
14.
Catheter Cardiovasc Interv ; 96(6): E646-E652, 2020 11.
Article in English | MEDLINE | ID: mdl-32073725

ABSTRACT

OBJECTIVE: To assess the utility of the 65-cm-long Gore DrySeal sheath when compared to the standard 36-cm-long Edwards expandable sheath (e-sheath) for transcatheter pulmonary valve implantation (TPVI) with the Edwards Sapien 3 valve. METHODS: All patients who underwent TPVI with the Sapien 3 valve, excluding those performed via hybrid approach, at our center between September 2015 and November 2019 were retrospectively reviewed and compared between two groups. RESULTS: A total of 94 patients were enrolled; 29 patients underwent TPVI with the Sapien valve using the DrySeal sheath and 65 underwent TPVI using the e-sheath. The height and body weight of patients implanted using the DrySeal sheath ranged from 137 to 193 cm and from 33 to 129 kg, respectively. Valve delivery time was significantly shorter in the DrySeal group (median time 4 min 33 s vs. 9 min 6 s, p = .002). There were no complications in the DrySeal group (0/27). Nine procedural complications occurred in the e-sheath group (9/65), five of which were potentially directly related to sheath choice, including tricuspid valve injury in four and embolization of the tip of the e-sheath during retrieval of a ruptured balloon in one patient. CONCLUSIONS: TPVI with the Sapien 3 valve using the 65-cm-long DrySeal sheath facilitates faster and safer valve implantation when compared to the e-sheath.


Subject(s)
Cardiac Catheterization/instrumentation , Cardiac Catheters , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Stenosis/surgery , Pulmonary Valve/surgery , Adolescent , Adult , Cardiac Catheterization/adverse effects , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Male , Middle Aged , Operative Time , Postoperative Complications/etiology , Prosthesis Design , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/physiopathology , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Stenosis/diagnostic imaging , Pulmonary Valve Stenosis/physiopathology , Retrospective Studies , Time Factors , Treatment Outcome , Young Adult
15.
Catheter Cardiovasc Interv ; 95(3): 365-372, 2020 02 15.
Article in English | MEDLINE | ID: mdl-31654558

ABSTRACT

OBJECTIVES: To compare residual shunt rate and complications associated with six different devices used for PFO closure. BACKGROUND: Transcutaneous PFO closure is an effective treatment for preventing recurrent stroke in patients with a history of cryptogenic stroke. The rate of residual shunt is one metric by which the technical success of PFO closure can be measured. METHODS: Patients who underwent PFO closure at a single center between February 2001 and July 2019 were retrospectively enrolled in the study. Right-to-left shunt at baseline and during follow-up was assessed using transcranial Doppler (TCD) or transthoracic echocardiography (TTE). Periprocedural and device-related complications, including atrial fibrillation, were also assessed. RESULTS: Of 467 PFO closures performed during this period, 320 patients received quantitative assessment of right-to-left shunting both before and after percutaneous closure. The highest effective closure was achieved with the Cardioform device (100%, n = 104), followed by the Amplatzer Cribriform (93%, n = 14), Helex (90%, n = 137), Amplatzer ASO (88%, n = 17), CardioSEAL (86%, n = 14), and Amplatzer PFO (85%, n = 33) devices. The most common significant adverse event was atrial fibrillation, which was more common with the Cardioform device (13%) than the Helex (4%) or the Amplatzer PFO (4%) devices. CONCLUSIONS: The Gore Cardioform Septal Occluder provides more robust closure of a PFO when compared to other devices but its effectiveness is offset by the higher prevalence of transient atrial fibrillation.


Subject(s)
Atrial Fibrillation/epidemiology , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Foramen Ovale, Patent/therapy , Hemodynamics , Septal Occluder Device , Stroke/prevention & control , Adult , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Female , Foramen Ovale, Patent/diagnostic imaging , Foramen Ovale, Patent/epidemiology , Foramen Ovale, Patent/physiopathology , Humans , Male , Middle Aged , Prevalence , Prosthesis Design , Recurrence , Retrospective Studies , Risk Factors , Stroke/diagnostic imaging , Stroke/epidemiology , Stroke/physiopathology , Time Factors , Treatment Outcome , United States/epidemiology
16.
Catheter Cardiovasc Interv ; 95(2): 253-261, 2020 02.
Article in English | MEDLINE | ID: mdl-31609055

ABSTRACT

OBJECTIVES: To describe our initial experience with pediatric transcatheter aortic valve replacement. BACKGROUND: Transcatheter aortic valve replacement (TAVR) has been approved and used to treat calcific aortic stenosis in adult patients. Select pediatric patients with congenital heart disease (CHD) who are poor candidates for conventional surgical aortic valve replacement can benefit from TAVR. METHODS: A retrospective review was performed to identify and describe pediatric patients with CHD who underwent transcatheter or hybrid aortic valve replacement using a Melody Valve (Medtronic, Minneapolis, MN), or Sapien S3/XT valve (Edwards Life sciences LLC, Irvine, CA). Patients in whom transcatheter valves were implanted on cardiopulmonary bypass were included. Imaging data, procedural elements, and clinical follow-up data were collected to evaluate acute and short-term results. RESULTS: A total of eight pediatric patients underwent treatment of aortic valvular disease using balloon expandable valves and delivery systems. Two patients had Melody valve implantation and six received a Sapien valve (one XT/five S3). In one patient, a Melody valve was placed surgically, failed, and was replaced with a Sapien valve 2 years later. Two patients were treated using a standard transfemoral route, four had the valve delivered on cardiopulmonary bypass via a median sternotomy, one was placed with a transapical approach, and one via a carotid cut down. Patients were followed for an average 16 months (range 1-208 weeks). There were no early or late deaths in this cohort. There were no embolic events, and all valves worked well in the immediate postoperative period. Both Melody implants developed moderate to severe regurgitation at 2 years and 4 years, respectively, and both required replacement at that time. One Sapien 3 valve developed a paravalvular leak that required reintervention within 6 months of implantation. CONCLUSIONS: Transcatheter valves offer a reasonable alternative to traditional surgical aortic valve replacement in certain pediatric patients who are suboptimal surgical candidates. Hybrid approaches and valve delivery on cardiopulmonary bypass has been used in smaller patients. Long-term performance of these valves in young patients has not been studied.


Subject(s)
Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/instrumentation , Adolescent , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Child , Child, Preschool , Device Removal , Hemodynamics , Humans , Prosthesis Design , Prosthesis Failure , Recovery of Function , Retrospective Studies , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
17.
Curr Cardiol Rep ; 22(12): 166, 2020 10 10.
Article in English | MEDLINE | ID: mdl-33037927

ABSTRACT

PURPOSE OF REVIEW: With increasing use of prosthetic valves to treat degenerative valvular heart disease (VHD) in an aging population, the incidence and adverse consequences of paravalvular leaks (PVL) are better recognized. The present work aims to provide a cohesive review of the available literature in order to better guide the evaluation and management of PVL. RECENT FINDINGS: Despite gains in operator experience and design innovation, significant PVL remains a significant complication that may present with congestive heart failure and/or hemolytic anemia. To date, clear consensus or guidelines on the evaluation and management of PVL remain lacking. Although the evolution of transcatheter valve therapies has had a tremendous impact on the management of patients with VHD, the limitations and complications of such techniques, including PVL, present further challenges. Incidence of PVL, graded as moderate or greater, ranges from 4 to 7.4% in surgical and transcatheter valve replacements, respectively. Improved imaging modalities and the advent of novel surgical and percutaneous therapies have undoubtedly yielded a better understanding of PVL including its anatomical location, mechanism, severity, and treatment options. Echocardiography, used in conjunction with cardiac computed tomography and cardiac magnetic resonance, provides essential details for diagnosis and management of PVL. Transcatheter intervention has become a favored approach in lieu of surgical intervention in select patients after previous surgical or percutaneous valve replacement. PVL treatment with vascular plugs, balloon post-dilation, and the valve-in-valve methods have shown technical success with promising clinical outcomes in appropriately selected patients.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Diseases , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/surgery , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Humans , Prosthesis Failure , Treatment Outcome
19.
Catheter Cardiovasc Interv ; 93(6): 1165-1169, 2019 05 01.
Article in English | MEDLINE | ID: mdl-30565408

ABSTRACT

Transcatheter valve replacement offers a safe and effective alternative to traditional surgical techniques in patients with congenital heart disease, especially those at high surgical risk. The most common causes of morbidity and mortality in patients with D-transposition of the great arteries status post Senning or Mustard repair is severe tricuspid valve (TV) regurgitation. Replacement of the systemic TV may be useful in those without severe systemic ventricular dysfunction. We present a case of a patient with D-loop transposition of the great arteries status post Mustard repair and TV ring placement with subsequent severe systemic TV regurgitation, at high surgical risk, who underwent a transcatheter valve replacement via a trans-apical approach using an Edwards Sapien XT valve.


Subject(s)
Cardiac Valve Annuloplasty/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve/surgery , Female , Hemodynamics , Humans , Middle Aged , Prosthesis Design , Recovery of Function , Severity of Illness Index , Treatment Outcome , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/physiopathology , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/physiopathology
20.
Catheter Cardiovasc Interv ; 94(4): 625-635, 2019 Oct 01.
Article in English | MEDLINE | ID: mdl-31471941

ABSTRACT

OBJECTIVES: We sought to delineate the risk factors for infective endocarditis (IE) in patients undergoing transcatheter pulmonary valve replacement (TCPVR). BACKGROUND: Despite the therapeutic benefits of TCPVR for treatment of dysfunctional right ventricular outflow tracts, IE is a major complication of the approach. Specific hemodynamic gradients and patient immune status as predisposing factors for IE are largely unexplored. METHODS: We performed a retrospective review of patients who had undergone TCPVR at UCLA between October 2010 and October 2017. Cases of IE were diagnosed based on the modified Duke criteria. RESULTS: Two hundred and thirty-five cases of TCPVR were performed with a mean follow-up of 2.6 years (range 0.0-8.0 years). Sixteen distinct IE events developed in 13 patients (Melody™ n = 12, SAPIEN n = 1), with a median time from implant to IE of 3.3 years (range 2.0-7.2 years). Univariate Cox regression showed that immunocompromised status was significantly associated with the development of IE hazard ratios (HR 5.43 [1.80-16.4], p = .003). Kaplan-Meier curves show that the 5-year freedom from IE among immunocompetent patients was 87% (95% CI 78-96%) versus 64% (95% CI 39-89%) among immunocompromised patients (log-rank p = .02). Postimplant right ventricular systolic pressure was higher among immunocompromised patients (p = .03). The risk of IE post-TCPVR in immunocompromised patients with residual pulmonary stenosis was 43%. CONCLUSIONS: Among the risk factors examined in this study, immunocompromised status was the most significant predictor of IE development post-TCPVR. Patients with the lowest risk of IE are those with competent immune systems, without a history of IE, and with minimal residual pulmonary valve gradients post-TCPVR.


Subject(s)
Cardiac Catheterization/adverse effects , Endocarditis/etiology , Heart Defects, Congenital/surgery , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis/adverse effects , Prosthesis-Related Infections/etiology , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Stenosis/surgery , Pulmonary Valve/surgery , Adolescent , Adult , Cardiac Catheterization/instrumentation , Clinical Decision-Making , Endocarditis/diagnosis , Endocarditis/immunology , Female , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/immunology , Heart Defects, Congenital/physiopathology , Heart Valve Prosthesis Implantation/instrumentation , Hemodynamics , Humans , Immunocompromised Host , Male , Progression-Free Survival , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/immunology , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/physiopathology , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/immunology , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Stenosis/diagnostic imaging , Pulmonary Valve Stenosis/immunology , Pulmonary Valve Stenosis/physiopathology , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL