Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 85
Filter
Add more filters

Country/Region as subject
Affiliation country
Publication year range
1.
Pacing Clin Electrophysiol ; 46(2): 185-189, 2023 02.
Article in English | MEDLINE | ID: mdl-36063407

ABSTRACT

The presence of mechanical heart valves in both aortic and mitral positions is a significant limitation for traditional left ventricular (LV) access, including retrograde transaortic and/or antegrade interatrial transseptal routes. We present a case of successful catheter ablation for ventricular tachycardia via a traditional transfemoral venous approach, which involves direct puncture of the inferior and medial aspect of the right atrium adjacent to the posteroseptal process of LV (PSPLV). Percutaneous trans-right atrial access to the left ventricle appears to be a safe and feasible method for catheter ablation of ventricular tachycardia in patients with mechanical aortic and mitral valves.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Tachycardia, Ventricular , Humans , Heart Ventricles/surgery , Mitral Valve/surgery , Atrial Fibrillation/surgery , Tachycardia, Ventricular/surgery , Heart Atria , Catheter Ablation/methods
2.
Kardiologiia ; 63(5): 47-52, 2023 May 31.
Article in Russian | MEDLINE | ID: mdl-37307208

ABSTRACT

Aim    The aim of this study was to determine the average minimum number of slow pathway ablation procedures required to reach a steady success rate among inexperienced operators.Material and Methods    We analyzed the consecutive AVNRT ablation procedures of three inexperienced operators for the rate of operational success and complications.Results    Operators performed a total of 156 AVNRT ablation procedures. There was no statistical significance between the three operators regarding the rate of success (p=0.69) and complications. There were significant differences between the operators in terms of procedure time, fluoroscopy time, and cumulative air kerma. The variability of procedure time and cumulative air kerma, both among three operators and within each operator, decreased significantly after the 25th case. Each operator was analyzed individually for the probability of success as related to the cumulative number of ablations. All trainee operators reached a success rate of 90 % at the 27th procedure.Conclusion    An average of 27 slow pathway ablation procedures should be performed by a beginner operator to achieve proficiency.


Subject(s)
Radiofrequency Ablation , Tachycardia, Atrioventricular Nodal Reentry , Humans , Learning Curve , Bundle of His , Probability
3.
J Cardiovasc Electrophysiol ; 33(1): 117-122, 2022 01.
Article in English | MEDLINE | ID: mdl-34674347

ABSTRACT

INTRODUCTION: Single-center observational studies have shown promising results with fragmented electrogram (FE)-guided ganglionated plexus (GP) ablation in patients with vagally mediated bradyarrhythmia (VMB). We aimed to compare the acute procedural characteristics during FE-guided GP ablation in patients with VMB performed by first-time operators and those of a single high-volume operator. METHODS AND RESULTS: This international multicenter cohort study included data collected over 2 years from 16 cardiac hospitals. The primary operators were classified according to their prior GP ablation experience: a single high-volume operator who had performed > 50 GP ablation procedures (Group 1), and operators performing their first GP ablation cases (Group 2). Acute procedural characteristics and syncope recurrence were compared between groups. Forty-seven consecutive patients with VMB who underwent FE-guided GP ablation were enrolled, n = 31 in Group 1 and n = 16 in Group 2. The mean number of ablation points in each GP was comparable between groups. The ratio of positive vagal response during ablation on the left superior GP was higher in Group 1 (90.3% vs. 62.5%, p = .022). Ablation of the right superior GP increased heart rate acutely without any vagal response in 45 (95.7%) cases. The procedure time was longer in group 2 (83.4 ± 21 vs. 118.0 ± 21 min, respectively, p < .001). Over a mean follow-up duration of 8.0 ± 3 months (range 2-24 months), none of the patients suffered from syncope. CONCLUSION: This multi-center pilot study shows for the first time the feasibility of FE-guided GP ablation across a large group of procedure-naïve operators.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Atrial Fibrillation/surgery , Bradycardia/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cohort Studies , Humans , Pilot Projects , Treatment Outcome , Vagus Nerve/surgery
4.
J Electrocardiol ; 70: 50-55, 2022.
Article in English | MEDLINE | ID: mdl-34922221

ABSTRACT

BACKGROUND: The aim of the present study is to investigate the possible factors that might be predictive of effective antiarrhythmic effect of beta-blockers on premature ventricular complexes (PVC). METHODS: Data of 190 eligible consecutive patients to whom beta-blocker therapy had been initiated for treatment of PVC's were retrospectively evaluated. The Holter recording acquired before beta-blocker initiation and the first Holter acquired after beta blocker initiation during follow up was comprehensively evaluated for each patient. Parameters obtained from pre- and post-beta-blocker 24 h Holter recordings were compared with each other and possible predictors were evaluated for positive response to beta-blocker therapy. RESULTS: Sixty-one patients (32.1%) were observed to respond beta-blocker therapy with at least 50% reduction of daily PVC burden. Patients who responded to beta-blockers had significantly higher ratio of patients who had positive correlation between hourly heart rate and corresponding hourly PVC number (fast HR-PVC status) compared with non-responders (73.8% vs 48.1%, p < 0.001). Binary logistic regression analysis revealed PVC QRS width (Odds ratio: 0.971; p: 0.037) and fast HR-PVC status (Odds ratio: 2.935; p: 0.007) as the independent predictors of positive response to beta-blockers for treatment of PVC. CONCLUSION: Positive correlation between hourly heart rate and PVC incidence was found to be independent positive predictor and PVC QRS width was found to be independent negative predictor of beta-blocker success in our study. This observation might have important clinical implications to guide medical treatment of PVCs in clinical practice.


Subject(s)
Catheter Ablation , Ventricular Premature Complexes , Adrenergic beta-Antagonists/therapeutic use , Electrocardiography , Electrocardiography, Ambulatory , Humans , Retrospective Studies
5.
Herz ; 46(5): 476-481, 2021 Oct.
Article in English | MEDLINE | ID: mdl-33464357

ABSTRACT

BACKGROUND: The aim of the present study was to determine the predictors of adequate intraprocedural premature ventricular complex (PVC) frequency for successful mapping and ablation of idiopathic PVCs. METHODS: A total of 101 consecutive patients (45 men; age: 47.9 ± 14.2 years) who had undergone idiopathic PVC ablation between 01 November 2018 and 24 June 2020 constituted our study population. Clinical and demographic data, procedural details and 24 h rhythm recordings that had been recorded before the procedure were retrospectively evaluated. Total PVC burden and diurnal variability assessed by the ratio of night time (22:00-06:00) over day time (06:00-22:00) PVC burden was calculated. The relationship between hourly PVC number and heart rate was also evaluated for each patient. Clinical characteristics and Holter parameters were compared between groups with and without adequate intraprocedural frequency of PVCs that permitted activation mapping. RESULTS: In all, 27 patients (26.7%) had infrequent intraprocedural PVCs which necessitated isoproterenol infusion or cancellation of ablation procedure due to inability of activation mapping. PVC burden was significantly higher in the group with frequent intraprocedural PVCs (26.1 ± 9.4% vs 21.2 ± 10.3%; p: 0.026). There were no significant differences between groups regarding the relationship between hourly PVC number and heart rate or the ratio of night/day PVC burden. Binary logistic regression analysis revealed the 24 h Holter PVC burden as the sole parameter that is significant predictor of frequent intraprocedural PVCs permitting activation mapping. CONCLUSION: The 24 h PVC burden was the only predictor of adequate intraprocedural PVC frequency permitting activation mapping during idiopathic PVC ablation.


Subject(s)
Catheter Ablation , Ventricular Premature Complexes , Adult , Heart Rate , Humans , Male , Middle Aged , Retrospective Studies , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/surgery
6.
Herz ; 46(1): 82-88, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33009623

ABSTRACT

BACKGROUND: The growing problem of endocardial lead infections and lead malfunctions has increased interest in percutaneous lead-removal technology. Transvenous lead extraction (TLE) via simple manual traction (SMT) is the first-line therapy. When SMT is not successful, TLE from the femoral vein using a gooseneck snare (GS) with a radiofrequency ablation catheter (RFAC) may be an alternative option. The aim of our study was to evaluate the success rate of transvenous extraction of chronically implanted leads via the femoral approach using a GS with RFCA in cases of failure with SMT. METHODS: The study included 94 consecutive patients who were referred for lead extraction due to pocket erosion and infection (71 patients) and to lead malfunction (23 patients). Initially, SMT was attempted for all patients. If SMT was not successful, patients underwent TLE using a GS with RFAC. RESULTS: Leads were extracted successfully with SMT in 34 patients (54 leads), while 60 patients (83 leads) underwent TLE using a GS with RFAC. The mean indwelling time of the leads was longer in the femoral approach with GS (87.5 ± 37.9 vs. 31.3 ± 25.8 months; p < 0.001). The procedural success rate was 96.7% in the femoral approach with GS. A preceding implantation lead duration of >51 months predicted an unsuccessful SMT necessitating alternative TLE using a GS with RFAC with 86% sensitivity and 78% specificity (p < 0.001). CONCLUSION: Transvenous lead extraction via the femoral approach using GS with RFAC may be an alternative approach to SMT with a high success rate, especially when the indwelling time of the leads is long.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Defibrillators, Implantable/adverse effects , Device Removal , Femoral Artery , Humans , Retrospective Studies , Treatment Outcome
7.
J Electrocardiol ; 59: 93-99, 2020.
Article in English | MEDLINE | ID: mdl-32035356

ABSTRACT

INTRODUCTION: ST segment elevation (STE) in the standard 12­lead surface electrocardiography (ECG) is a well-known finding in patients with metastatic cardiac tumors. It is important to identify the specific characteristics of STE among those patients to prevent unnecessary aggressive treatments. In the present study, we aimed to demonstrate the ECG characteristics of patients with metastatic cardiac tumors who has STE. MATERIAL AND METHODS: Medical literature was searched from Pubmed database with key words "metastatic cardiac tumors" or "cardiac tumors" and "ST segment elevation" or "ST elevation". In addition, remaining articles were explored using the references of case reports which were obtained during former screening (snowball procedure). RESULTS: Thirty six of 46 case reports were included and ECG characteristics of each case were evaluated. Convex- shaped STE was observed in all patients and it showed a specific coronary territory in 35 of 36 patients (97.2%). Pathologic Q wave and/or loss of R wave progression were observed in only one patient. T wave inversion following STE was detected in 34 patients (94.4%). STE evolution was absent in 32 of 36 patients while the information regarding STE evolution were not provided in the remaining cases. CONCLUSION: STE due to tumor invasion has certain characteristics which could help clinicians in the differential diagnosis.


Subject(s)
Heart Neoplasms , Myocardial Infarction , Arrhythmias, Cardiac , Diagnosis, Differential , Electrocardiography , Heart Neoplasms/diagnosis , Humans , Myocardial Infarction/diagnosis
8.
J Electrocardiol ; 61: 71-76, 2020.
Article in English | MEDLINE | ID: mdl-32554159

ABSTRACT

OBJECTIVES: Data is scarce regarding the relation between P wave indices and new onset atrial fibrillation (NOAF) after trans-catheter aortic valve replacement (TAVR). AIMS: The present study aimed to find out certain characteristics of P wave that may predict NOAF after TAVR procedure. METHOD: Patients with severe calcific aortic stenosis who had undergone TAVR procedure between 2013 and 2019 in two centers were investigated. P wave abnormalities that have been resumed to reflect impaired atrial conduction; partial and advanced inter atrial block (IAB), P-wave terminal force in lead V1, P wave dispersion, reduced amplitude of P- wave in lead I, P wave peak time in D2 and V1 were evaluated on pre- procedural 12 derivation surface electrocardiography (ECG). The relationship between these parameters and incidence of NOAF during index hospitalization was evaluated. RESULTS: A total of 227 consecutive patients (median age 79 [74-83]; 134 [59%] female) were included in the study. NOAF occurred in 46 (20.3%) patients. P wave duration, P wave dispersion, number of patients with partial and advanced IAB, left atrium diameter, STS score were higher in NOAF patients. Use of general anesthesia and history of prior open heart surgery were also more frequent in NOAF group. In multivariable logistic regression analysis; advanced IAB (OR 6.413 [2.555-16.095] p < 0.01), P wave dispersion (OR 3.544 [1.431-8.780] p = 0.006) and use of general anesthesia (OR 2.736 [1.225-6.109] p = 0.014) were independent predictors of NOAF. CONCLUSION: Among P wave abnormalities evaluated on pre-procedural 12-derivation surface ECG, advanced IAB and P wave dispersion may predict NOAF after TAVR procedure.


Subject(s)
Aortic Valve Stenosis , Atrial Fibrillation , Transcatheter Aortic Valve Replacement , Aged , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Atrial Fibrillation/diagnosis , Catheters , Electrocardiography , Female , Humans , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects
9.
Pacing Clin Electrophysiol ; 42(12): 1573-1578, 2019 12.
Article in English | MEDLINE | ID: mdl-31696518

ABSTRACT

BACKGROUND: The aim of the present study is to evaluate whether catheter-induced premature ventricular complexes (PVCs) produced at the presumptive ablation site may aid in the identification of the optimal timing of the earliest local activation for the successful ablation of clinical PVCs. METHODS: Sixty-three consecutive patients (35 males, age: 53.5 ± 14.4 years) without any exclusion criteria who had undergone PVC ablation between 1 July 2018 and 1 July 2019 constituted our study population. The time interval between the beginning of the EGM and the beginning of the QRS of each catheter-induced PVC (Cath EGM-ECG) and the time interval between the beginning of the EGM of clinical PVCs at the earliest site and the beginning of the QRS of clinical PVCs (PVC earliest EGM-ECG) were noted for each patient. The value of Cath EGM-ECG as a reference for procedural success of ablation was evaluated by examining the relationship between Cath EGM-ECG and PVC earliest EGM-ECG. RESULTS: Fifty-two patients had successful ablation, and 43 of them (82.7%) had PVC earliest EGM-ECG values greater than or equal to Cath EGM-ECG. Eleven patients had procedural failure, and all of them had PVC earliest EGM-ECG values lower than Cath EGM-ECG. A PVC earliest EGM-ECG value -1.5 ms greater than Cath EGM-ECG predicted successful ablation with a sensitivity of 90.4% and a specificity of 100.0% in the general patient population. CONCLUSION: Cath EGM-ECG seems to serve as a reliable guide for finding the optimal timing of the earliest site for successful PVC ablation.


Subject(s)
Cardiac Catheterization , Catheter Ablation , Ventricular Premature Complexes/physiopathology , Ventricular Premature Complexes/surgery , Electrocardiography , Female , Humans , Male , Middle Aged
10.
Pacing Clin Electrophysiol ; 42(3): 321-326, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30653680

ABSTRACT

BACKGROUND: The deterioration of left atrial and ventricular functions was demonstrated in patients with frequent ventricular extrasystole (fVES). The exact pathophysiology of left atrial dysfunction in patients with fVES is unclear. Retrograde ventriculoatrial conduction (VAC) often accompanies fVES, which may contribute to atrial dysfunction. We investigated whether atrial electromechanical delay and VAC are related to these atrial functions in patients with frequent right ventricular outflow tract (RVOT) VES and preserved ejection fraction (pEF). METHODS: This study included 21 patients with pEF (eight males, 48 ± 11 years), who had experienced more than 10 000 RVOT-VES during 24-h Holter monitoring and had undergone electrophysiological study/ablation. The study also included 20 healthy age- and sex-matched control subjects. Transthoracic echocardiography was performed on all of the subjects. Atrial conduction time was obtained by using tissue Doppler imaging. Strain analysis was performed with two-dimensional speckle tracking echocardiography. RESULTS: The peak atrial longitudinal strain was significantly impaired in patients with fVES (P = 0.01). In addition, although the interatrial and left atrial conduction delay times were significantly different between each group (P < 0.001, P < 0.001), the right atrial conduction delay times were similar. When patients with fVES were divided into groups depending on the existence of retrograde VAC, atrial deformation parameters and conduction delay time did not significantly differ between either group. CONCLUSION: Frequent RVOT-VES causes left atrial dysfunction. This information is obtained through strain analyses and recordings of left atrial conduction times in patients with pEF. Regardless, retrograde VAC is not related to atrial dysfunction.


Subject(s)
Cardiac Complexes, Premature/physiopathology , Heart Atria/physiopathology , Heart Conduction System/physiopathology , Stroke Volume , Ventricular Outflow Obstruction/physiopathology , Cardiac Complexes, Premature/surgery , Case-Control Studies , Catheter Ablation , Echocardiography, Doppler , Electrocardiography, Ambulatory , Female , Heart Atria/surgery , Heart Conduction System/surgery , Humans , Male , Middle Aged , Ventricular Outflow Obstruction/surgery
11.
J Electrocardiol ; 51(3): 409-412, 2018.
Article in English | MEDLINE | ID: mdl-29525385

ABSTRACT

Malignant ventricular arrhythmias are challenging to manage, requiring a multidisciplinary approach. The mechanism, which triggers ventricular fibrillation (VF) associated with ventricular extrasystoles has not been clarified yet, however, abolishing ventricular extrasystoles may stop ventricular fibrillation in these patients. By this case presentation, we aimed to present a successful treatment of an electrical storm (ES), which developed after an acute myocardial infarction, by catheter ablation.


Subject(s)
Catheter Ablation/methods , Ventricular Fibrillation/surgery , Coronary Angiography , Defibrillators, Implantable , Diagnosis, Differential , Echocardiography , Electrocardiography , Humans , Male , Middle Aged , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/physiopathology
13.
Echocardiography ; 34(12): 1948-1949, 2017 12.
Article in English | MEDLINE | ID: mdl-29082593

ABSTRACT

A 19-year-old male patient was admitted to our institute with dyspnea. His medical history had no rheumatic fever or infective endocarditis. Physical examination revealed a diastolic murmur over the aortic area, rales of bilateral lungs. Bedside transthoracic echocardiography (TTE) revealed a severe aortic regurgitation (AR) without aortic valve stenosis and a moderately dilated left ventricle accompanied by an ejection fraction of 55%. The aortic valve could not be clearly demonstrated as either bicuspid or tricuspid. Congenital AR typically occurs in conjunction with an additional cardiac abnormality or aortic valve stenosis. Furthermore, bicuspid aortic valves are observed in the majority of patients. The aortic valve is created from the truncus ridge of the truncus arteriosus while the embryological development.


Subject(s)
Aortic Valve Insufficiency/congenital , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve/abnormalities , Echocardiography/methods , Adult , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/physiopathology , Diagnosis, Differential , Echocardiography, Transesophageal , Humans , Male , Young Adult
14.
Echocardiography ; 34(9): 1376-1378, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28681443

ABSTRACT

A 36-year-old female was admitted to hospital exhibiting chest pain, dyspnea, and a heart murmur on the right upper sternal border, radiating to both carotid arteries. The blood pressure of the patient's right arm exceeded the pressure in the left by 25 mm Hg (Coanda effect). In spite of laboratory results that did not fall outside the expected range, the left ventricle was revealed to be hypertrophic following electrocardiography. Transthoracic echocardiography revealed a severe supravalvular aortic stenosis (SVAS) with a peak Doppler velocity of 6.04 cm/s and an estimated mean pressure gradient of 89 mm Hg, with moderate aortic and mitral regurgitation. Contrast-enhanced computed tomography (CCT) indicated a partial hourglass-shaped narrowing of the ascending aorta. Lesions associated with supravalvular stenosis of the pulmonary artery, patent ductus arteriosus, and aortic coarctation were ruled out by the CCT. Congenital SVAS is a rare heart condition, and three anatomically distinct forms have been described. The most common type is the "hourglass," which produces a marked thickening and disorganization of the aortic tissue, producing a constricting annular ridge at the superior margin of the sinuses of Valsalva.


Subject(s)
Aorta, Thoracic/diagnostic imaging , Aortic Stenosis, Supravalvular/diagnosis , Aortic Valve/diagnostic imaging , Echocardiography, Doppler/methods , Magnetic Resonance Imaging, Cine/methods , Multimodal Imaging , Tomography, X-Ray Computed/methods , Adult , Aortic Stenosis, Supravalvular/congenital , Aortic Valve/abnormalities , Diagnosis, Differential , Electrocardiography , Female , Humans
15.
Echocardiography ; 34(11): 1714-1716, 2017 Nov.
Article in English | MEDLINE | ID: mdl-29071746

ABSTRACT

A 24-year-old man was admitted to our outpatient clinic for his routine checkup of consecutively percutaneously treated atrial septal defect (ASD) and pulmonary valvular stenosis 45 days ago. A 24 mm ASD occluder device was implanted under transthoracic echocardiographic guidance and 80 mm Hg peak-to-peak pulmonary valvular gradient decreased to 20 mm Hg gradient after pulmonary valve dilatation with 23 mm NUMED II transluminal valvuloplasty catheter balloon. Atrial septal defect (ASD) closure is now routinely performed using a percutaneous approach under echocardiographic guidance especially transthoracic echocardiography (TEE). Centrally located, ostium secundum type and less than 3.5 cm in size are considered ideal for device closure. Although there is considerable variation in size and location of the defects, TEE guidance is quite important for this proportion of ASDs. The selection of patients for percutaneous transcatheter closure of a secundum ASD requires accurate information regarding the anatomy of the defect such as its maximal diameter and the amount of circumferential tissue rims.


Subject(s)
Echocardiography/methods , Foreign-Body Migration/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Heart Ventricles/diagnostic imaging , Pulmonary Valve Stenosis/complications , Septal Occluder Device , Adult , Foreign-Body Migration/surgery , Heart Septal Defects, Atrial/complications , Heart Ventricles/surgery , Humans , Male , Treatment Outcome , Young Adult
16.
Clin Sci (Lond) ; 126(4): 297-304, 2014 Feb.
Article in English | MEDLINE | ID: mdl-23947743

ABSTRACT

The presence of the metabolic syndrome is a strong predictor for the presence of NASH (non-alcoholic steatohepatitis) in patients with NAFLD (non-alcoholic fatty liver disease). In the present study, we assessed LA (left atrial) deformation parameters in patients with NAFLD using 2D-STE (speckle tracking echocardiography) and to investigate if any changes exist between subgroups of the NAFLD. A total of 55 NAFLD patients and 21 healthy controls were included in the study. The diagnosis of NAFLD was based on liver biopsy. After patients were categorized into groups according to histopathological analysis (simple steatosis, borderline NASH, definitive NASH), all patients underwent echocardiography with Doppler examination. In the 2D-STE analysis of the left atrium, LA-Res (peak LA strain during ventricular systole), LA-Pump (peak LA strain during atrial systole), LA-SR(S) (peak LA strain rate during ventricular systole), LA-SR(E) (peak LA strain rate during early diastole) and LA-SR(A) (peak LA strain rate during atrial systole) were obtained. LA-Res, LA-Pump and LA-SR(A) were lower in the NAFLD group than in the control group. LA-Res was found to be significantly lower in NAFLD subgroups compared with healthy subjects (43.9±14.2 in healthy controls compared with 31.4±8.3 with simple steatosis, 32.8±12.8 with borderline NASH and 33.8±9.0 with definitive NASH). LA-Pump was significantly lower in the NAFLD group (18.2±3.1 in healthy controls compared with 13.3±4.7 with borderline NASH and 14.4±4.7 with definitive NASH). There were significant differences in LA-SR(A) between healthy controls compared with simple steatosis and borderline NASH (-1.56±0.36 compared with 1.14±0.38 and 1.24±0.32 respectively). Correlation analysis showed significant correlation of LA-Res values with E (early diastolic peak velocity)/E(m) (early diastolic mitral annular velocity) ratio (r=-0.50, P≤0.001), with LAVI (LA volume index; r=-0.45, P≤0.001) and with V(p) (propagation velocity; r=0.39, P≤0.001). 2D-STE-based LA deformation parameters are impaired in patients with NAFLD with normal systolic function. Although LA-Res and pump function parameters might be useful in estimating LV (left ventricular) filling pressure in the NAFLD patient group, it could not be used for differentiating the subgroups.


Subject(s)
Atrial Function, Left/physiology , Fatty Liver/physiopathology , Heart Atria/physiopathology , Heart Ventricles/physiopathology , Ventricular Dysfunction, Left/physiopathology , Adult , Diagnostic Imaging/methods , Echocardiography/methods , Fatty Liver/diagnosis , Female , Heart Atria/diagnostic imaging , Heart Ventricles/diagnostic imaging , Humans , Male , Middle Aged , Non-alcoholic Fatty Liver Disease , Systole/physiology , Ventricular Dysfunction, Left/diagnostic imaging
17.
Pacing Clin Electrophysiol ; 37(12): 1665-70, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25041179

ABSTRACT

BACKGROUND: The two predominant etiologies of right ventricular tachycardia (VT) are arrhythmogenic right ventricular cardiomyopathy (ARVC) and idiopathic VT arising from the right ventricular outflow tract (RVOT). Discrimination between these two entities is critical, as their prognoses and therapeutic options differ. The Tpeak -Tend (Tpe) interval reflects the transmural repolarization dispersion and its prolongation is associated with high mortality. METHODS: We compared the sinus rhythm electrocardiogram (ECG) of 43 patients (24 male, 43 ± 16 years) with VT originating from right ventricle. Five patients under antiarrhythmic drug therapy were excluded. Tpe interval was measured in each precordial leads and compared among patients with ARVC and RVOT-VT. RESULTS: Twenty-five patients (16 male, 42 ± 16 years) met the Task Force criteria for the diagnosis of ARVC, and 13 patients (seven male, 45 ± 14 years) had idiopathic RVOT tachycardia. Patients with ARVC had significantly prolonged Tpe intervals in all precordial leads compared to patients with idiopathic RVOT VT (137.1 ± 32.6 ms vs 93.8 ± 16.9 ms; P < 0.001 in V1, 133.2 ± 35.5 ms vs 104.7 ± 16.9 ms; P = 0.01 in V2, 125.7 ± 31.5 ms vs 99.1 ± 19.6 ms; P = 0.09 in V3, 121.9 ± 26.5 ms vs 92.3 ± 19.7 ms; P = 0.001 in V4, 123.1 ± 26.5 ms vs 99.5 ± 20:1 ms; P = 0.04 in V5 and 126.9 ± 32.2 ms vs 89 ± 11.3 ms; P < 0.001 in V6, respectively). For the diagnosis of ARVC, Tpe cut-off value of 97 ms in V1 had 84% sensitivity and 62% specificity (area under curve = 0.880). CONCLUSION: In patients with VT of RV origin, the prolonged Tpe interval in sinus rhythm electrocardiogram supports the diagnosis of ARVC.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia/diagnosis , Electrocardiography , Tachycardia, Ventricular/diagnosis , Adult , Diagnosis, Differential , Female , Heart Ventricles , Humans , Male , Retrospective Studies
18.
J Heart Valve Dis ; 23(3): 279-88, 2014 May.
Article in English | MEDLINE | ID: mdl-25296449

ABSTRACT

BACKGROUND AND AIM OF THE STUDY: Bicuspid aortic valve (BAV), one of the most common congenital cardiac abnormalities, is the result of abnormal aortic leaflet formation during valvulogenesis. Recent studies have reported BAV to be associated with abnormal aortic stiffness, which has a negative impact on left ventricular (LV) diastolic function. The study aim was to investigate the relationship between LV diastolic function, as measured with two-dimensional speckle tracking echocardiography (2D-STE), and arterial stiffness. METHODS: A total of 38 patients with isolated BAV, and 18 age- and gender-matched healthy controls were enrolled prospectively. Patients with aortic valve velocity > 1.7 m/s, more than mild aortic regurgitation (AR) and ascending aorta diameter > 3.6 cm (indexed diameter > 2.1 cm/m2) were excluded. BAV was classified as either anterior-posterior (AP) orientation or right-left (RL) orientation. The LV diastolic function (E/A and E/Em ratio), left atrial (LA) volume index (LAVI), LA systolic strain and strain rate (SR) was assessed using echocardiography. Strain measurements were reported as longitudinal LA strain during ventricular systole (LA-Res), strain during late diastole (LA-Pump), and also as SR during ventricular contraction (LA-SR(s)), during passive ventricular filling (LA-SR(E)), and during active atrial contraction (LA-SR(A)) from four-chamber views. Arterial stiffness was evaluated by measuring the aortic pulse wave velocity (PWV), wave reflection was assessed by measuring the central systolic blood pressure (cSBP), central pulse pressure (cPP) and augmentation index (AIx) with applanation tonometry. RESULTS: The aortic diameter at the proximal ascending aorta was larger in patients with BAV than in controls. Compared to controls, the E/Em ratio and LAVI were significantly higher in BAV patients. Although PWV was higher in BAV patients than in controls, no differences were found between the groups in terms of cSBP, cPP and AIx. The BAV group was observed to have significant lower LA-Res and LA-Pump strain values compared to controls. Significant correlations were identified between the PWV and echocardiographic parameters of LV diastolic function determinants, such as LA-Res and LA-Pump. However, there were no significant differences between BAV subgroups in terms of LV diastolic parameters and PWV. CONCLUSION: Patients with isolated BAV have early features of subclinical LV diastolic dysfunction, as measured with 2D-STE. In addition, aortic stiffness assessed by PWV was impaired. The LV diastolic parameters were related to aortic stiffness.


Subject(s)
Aortic Valve/abnormalities , Heart Valve Diseases/physiopathology , Vascular Stiffness , Ventricular Dysfunction, Left/physiopathology , Aorta/anatomy & histology , Aorta/pathology , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Aortic Valve/physiopathology , Bicuspid Aortic Valve Disease , Blood Flow Velocity , Diastole , Female , Heart Atria/physiopathology , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/pathology , Humans , Male , Manometry/methods , Reproducibility of Results , Ultrasonography , Ventricular Dysfunction, Left/diagnostic imaging
19.
J Electrocardiol ; 47(1): 113-7, 2014.
Article in English | MEDLINE | ID: mdl-24119748

ABSTRACT

BACKGROUND: YouTube has become a useful resource for knowledge and is widely used by medical students as an e-learning source. The purpose of this study was to assess the videos relating electrocardiogram (ECG) on YouTube. METHODS: YouTube was searched on May 28, 2013 for the search terms "AF ecg" for atrial fibrillation, "AVNRT" for atrioventricular nodal reentrant tachycardia, "AVRT" for atrioventricular reentrant tachycardia, "AV block or heart block" for atrioventricular block, "LBBB, RBBB" for bundle branch block, "left anterior fascicular block or left posterior fascicular block" for fascicular blocks, "VT ecg" for ventricular tachycardia, "long QT" and "Brugada ecg". Non-English language, unrelated and non-educational videos were excluded. Remaining videos were assessed for usefulness, source and characteristics. Usefulness was assessed with using a checklist developed by the authors. RESULTS: One hundred nineteen videos were included in the analysis. Sources of the videos were as follows: individuals n=70, 58.8%, universities/hospitals n=10, 8.4% and medical organizations n=3, 2.5%, health ads n=10 8.4%, health websites n=26, 21.8%. Fifty-six (47.1%) videos were classified as very useful and 16 (13.4%) videos were misleading. 90% of the videos uploaded by universities/hospitals were grouped as very useful videos, the same ratio was 45% for the individual uploads. There were statistically significant differences in ECG diagnosis among the groups (for very useful, useful and misleading, p<0.001, 0.02 and 0.008, respectively). The ratio of the misleading information in ventricular tachycardia videos was found to be 42.9%. CONCLUSIONS: YouTube has a substantial amount of videos on ECG with a wide diversity from useful to misleading content. The lack of quality content relating to ECG on YouTube necessitates that videos should be selected with utmost care.


Subject(s)
Arrhythmias, Cardiac/diagnosis , Computer-Assisted Instruction/statistics & numerical data , Educational Measurement/statistics & numerical data , Electrocardiography/statistics & numerical data , Internet/statistics & numerical data , Software , User-Computer Interface , Educational Measurement/methods , Humans
20.
Turk Kardiyol Dern Ars ; 42(7): 629-34, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25490297

ABSTRACT

OBJECTIVES: The aim was to investigate the microbiological characteristics and complications of infective endocarditis (IE) in 119 patients treated in our center for IE, diagnosed by modified Duke criteria. STUDY DESIGN: The archive records of 119 patients (82 [69%] males; 37 [31%] females; mean age 39 ± 16 years) with a definite diagnosis of IE between January 1997 and November 2004 were systematically reviewed for clinical and microbiological properties and complications. RESULTS: The most common complaint of the patients was fever and malaise (102 patients, 85.7%, each). Culture was negative in 68 patients (57.1%), while Staphylococcus aureus was the most common etiological agent in culture positive cases. The aortic valve was the most common region of vegetation (43 patients, 36.1%). The frequency of surgical operation for valvular insufficiency due to IE was 75.6%, and the frequency of congestive heart failure was 53.8% (64 patients). CONCLUSION: IE is still an important disease considering its high morbidity and mortality rates, increased life expectancy of the patients, and increased number of valve replacement procedures.


Subject(s)
Endocarditis, Bacterial/epidemiology , Staphylococcal Infections/epidemiology , Staphylococcus aureus/isolation & purification , Adult , Aortic Valve/microbiology , Endocarditis, Bacterial/complications , Endocarditis, Bacterial/microbiology , Female , Humans , Male , Mitral Valve/microbiology , Retrospective Studies , Staphylococcal Infections/complications , Staphylococcal Infections/microbiology , Turkey/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL