Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
Am J Obstet Gynecol MFM ; 6(3): 101306, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38301997

ABSTRACT

Preeclampsia remains the leading cause of maternal morbidity and mortality and is associated with abnormal body fluid homeostasis and cardiovascular dysfunction. Moreover, 2 distinct hemodynamic phenotypes have been described in preeclampsia, which might require different therapeutic approaches. Fluid restriction is mandatory in women at risk of pulmonary edema, whereas additional fluid administration may be required to correct tissue hypoperfusion in women with intravascular volume depletion. As clinical examination alone cannot discriminate among different hemodynamic patterns, optimal management of women with preeclampsia remains challenging. Noninvasive bedside ultrasound has become an important diagnostic and monitoring tool in critically ill patients, and it has been demonstrated that it can also be used in the monitoring of women with preeclampsia. Echocardiography in combination with lung ultrasound provides information on hemodynamic status, cardiac function, lung congestion, and fluid responsiveness and, therefore, could help clinicians identify women at higher risk of life-threatening complications. This review describes the cardiovascular changes in preeclampsia and provides an overview of the ultrasound methodologies that could be efficiently used for better hemodynamic assessment and management of women with preeclampsia.


Subject(s)
Pre-Eclampsia , Pregnancy , Humans , Female , Pre-Eclampsia/diagnosis , Hemodynamics , Echocardiography/methods , Lung/diagnostic imaging , Ultrasonography
2.
Int J Cardiovasc Imaging ; 40(4): 757-767, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38159132

ABSTRACT

The concept of disproportionate mitral regurgitation (dispropMR) has been introduced to identify patients with functional mitral regurgitation (MR) who benefit from percutaneous treatment. We aimed to examine echocardiographic characteristics behind this entity. We retrospectively included 172 consecutive patients with reduced left ventricular ejection fraction (LVEF), and more than mild MR referred to clinically indicated echocardiography. According to the proportionality ratio (effective regurgitant orifice area (EROA)/left ventricular end-diastolic volume (LVEDV)) patients were divided into dispropMR and proportionate MR (propMR) group. Potential factors which might affect proportionality definition were analyzed. 55 patients (32%) had dispropMR. Discrepant grading of MR severity was observed when using regurgitant volume (RegVol) by proximal isovelocity surface area (PISA) method or volumetric method, with significant discordance only in dispropMR (p < 0.001). Patients with dispropMR had more frequently left ventricular foreshortened images for LVEDV calculation than patients with propMR (p = 0.003), resulting in smaller LVEDV in dispropMR group. DispropMR group had more substantial dynamic variation of regurgitant flow compared to propMR. Accordingly, EROA was consistently overestimated by standard single-point PISA method compared to serial PISA method. This was more pronounced in dispropMR (bias:10.5 ± 28.3 mm2) compared to propMR group (bias:6.4 ± 12.8 mm2). DispropMR may be found in roughly one third of clinically indicated echocardiographic studies in patients with reduced LVEF and more than mild MR. EROA overestimation due to dynamic variation of regurgitant flow and LVEDV underestimation due to LV foreshortening were more frequently found in dispropMR. Our results indicate that methodological limitations of echocardiographic MR grading could not be neglected in classifying the proportionality of MR.


Subject(s)
Mitral Valve Insufficiency , Mitral Valve , Predictive Value of Tests , Severity of Illness Index , Stroke Volume , Ventricular Function, Left , Humans , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/classification , Retrospective Studies , Female , Male , Aged , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Middle Aged , Reproducibility of Results , Echocardiography, Doppler, Color , Aged, 80 and over
3.
Life (Basel) ; 13(6)2023 Jun 14.
Article in English | MEDLINE | ID: mdl-37374168

ABSTRACT

Resting and exercise right heart catheterisation is the gold standard method to diagnose and differentiate types of pulmonary hypertension (PH). As it carries technical challenges, the question arises if non-invasive exercise stress echocardiography may be used as an alternative. Exercise echocardiography can unmask exercise PH, detect the early stages of left ventricular diastolic dysfunction, and, therefore, differentiate between pre- and post-capillary PH. Regardless of the underlying aetiology, a developed PH is associated with increased mortality. Parameters of overt right ventricle (RV) dysfunction, including RV dilation, reduced RV ejection fraction, and elevated right-sided filling pressures, are detectable with resting echocardiography and are associated with worse outcome. However, these measures all fail to identify occult RV dysfunction. Echocardiographic measures of RV contractile reserve during exercise echocardiography are very promising and provide incremental prognostic information on clinical outcome. In this paper, we review pulmonary haemodynamic response to exercise, briefly describe the modalities for assessing pulmonary haemodynamics, and discuss in depth the contemporary key clinical application of exercise stress echocardiography in patients with PH.

4.
J Matern Fetal Neonatal Med ; 34(3): 379-385, 2021 Feb.
Article in English | MEDLINE | ID: mdl-31056999

ABSTRACT

Objectives: To compare soluble-ST2 (sST2) concentrations in patients with severe features of preeclampsia and healthy pregnant controls before as well as 1 year after delivery. Another objective was to assess potential correlation between sST2 concentrations and myocardial function.Methods: Patients with singleton pregnancy complicated by severe features of preeclampsia and healthy controls were included in a prospective observational study. Plasma sST2 concentrations were measured within 24 h before delivery and 1 year after delivery. Standard two-dimensional and Doppler echocardiography was performed at the time of first sST2 measurement before delivery. Mann-Whitney U test was used to compare sST2 values in preeclamptic patients versus controls. Kendall's tau was used to assess correlation between sST2 values and echocardiographic measures of left ventricular systolic and diastolic function (p < .05 significant).Results: We included 24 patients with severe preeclampsia and 29 controls. One year after delivery, sST2 concentrations were available for 24 (45%) participants (13 in preeclampsia group and 11 controls). Concentrations of sST2 were markedly elevated in patients with severe preeclampsia compared to healthy controls before delivery (p = .04), but not 1 year after delivery (p = .80). There was no significant correlation between sST2 and parameters of systolic function. In preeclamptic patients, we found a significant inverse correlation between sST2 and markers of diastolic function: peak early mitral inflow velocity E (Kendall's tau = -0.40; p = .02), peak early diastolic myocardial velocities at septal and lateral mitral annulus (e') (Kendall's tau = -0.354, p = .04) and ratio between e' and peak systolic myocardial velocities at the septal and lateral mitral annulus (e'/s') (Kendall's tau = -0.362, p = .04).Conclusions: Preeclampsia with severe features is associated with increased maternal plasma concentrations of sST2, which return to normal values in the first year after delivery. Higher sST2 levels in preeclamptic patients correlate with impaired parameters of left ventricular diastolic function.


Subject(s)
Pre-Eclampsia , Ventricular Dysfunction, Left , Diastole , Echocardiography , Echocardiography, Doppler , Female , Humans , Pre-Eclampsia/diagnostic imaging , Pregnancy , Reference Values , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Function, Left
5.
JACC Case Rep ; 3(6): 932-934, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34317658

ABSTRACT

A large left ventricular pseudoaneurysm was discovered in a patient who presented with bacterial endophthalmitis 1 year after medically treated Staphylococcus aureus mitral valve endocarditis. After medical therapy, the patient underwent cardiac surgery uneventfully. We present a rare finding of a pseudoaneurysm complicated with a very late ocular septic event. (Level of Difficulty: Advanced.).

6.
Int J Cardiovasc Imaging ; 37(7): 2217-2225, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33713218

ABSTRACT

Preeclampsia is associated with left ventricular (LV) geometrical and functional changes, which could be related to cardiovascular risk later in life. The purpose of our study was to evaluate evolution of LV dimensions and function in severe preeclamptic women from immediately post-delivery to 1 year postpartum. Twenty-five women with severe preeclampsia and 15 healthy term controls underwent standard and speckle-tracking echocardiography 1 day after delivery and 1 year postpartum. On day 1 post-delivery preeclamptic women were exposed to higher preload (p = 0.003) and afterload (p < 0.001) compared to controls. Parameter of longitudinal LV systolic function s' was significantly lower in preeclamptic compared to control group (p = 0.017) 1 day post-delivery. Additionally, diastolic function parameters were significantly more impaired in preeclamptic compared to control group (lower e' (p = 0.02) and higher E/e' ratio (p = 0.003) in preeclamptic group). Larger LV mass (p = 0.03) and a trend of higher proportion of altered cardiac geometry (p = 0.061) were observed in preeclampsia 1 day post-delivery. One year after delivery both groups had comparable geometric and functional parameters with similar afterload and preload (p > 0.05, for all). In preeclamptic group systolic and diastolic functional parameters improved significantly during follow-up (p < 0.05), while no such evolution was noted in controls (> 0.05). In women with severe preeclampsia subtle cardiac functional impairment immediately post-delivery completely resolved 1 year postpartum. Observed cardiac alterations suggest intrinsic myocardial dysfunction in preeclampsia, which became unmasked or exacerbated by higher load imposed on the LV immediately post-delivery that disappeared in mid-term follow-up.


Subject(s)
Pre-Eclampsia , Ventricular Dysfunction, Left , Case-Control Studies , Female , Heart , Humans , Postpartum Period , Pre-Eclampsia/diagnostic imaging , Predictive Value of Tests , Pregnancy , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/etiology , Ventricular Function, Left
7.
Hypertens Pregnancy ; 40(1): 9-14, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33205686

ABSTRACT

Objective: To examine the correlation between plasma cerebral biomarkers (S100B and neuron-specific enolase (NSE)) and ultrasonographic optic-nerve-sheath-diameter (ONSD) in preeclampsia. Methods: Thirty preeclampsia patients and 27 controls were included. Mann-Whitney-U test was used for comparison of S100B, NSE, and ONSD in preeclampsia vs. controls. Kendall's tau was used to assess the correlation between biomarkers and ONSD (p < 0.05 significant). Results: ONSD, S100B and NSE were significantly higher in preeclampsia (p < 0.001, p = 0.004, and p < 0.001, respectively). There was significant correlation between NSE levels and ONSD: Kendall's tau = 0.26; p = 0.01. Conclusions: S100B and NSE are elevated in severe preeclampsia. NSE correlates with increased ONSD suggesting cerebral edema.


Subject(s)
Biomarkers/blood , Optic Nerve/diagnostic imaging , Phosphopyruvate Hydratase/blood , Pre-Eclampsia/blood , S100 Calcium Binding Protein beta Subunit/blood , Ultrasonography/methods , Adult , Brain Edema/blood , Case-Control Studies , Female , Humans , Pregnancy , Prospective Studies
8.
Anaesth Crit Care Pain Med ; 40(1): 100800, 2021 02.
Article in English | MEDLINE | ID: mdl-33453456

ABSTRACT

OBJECTIVE: To determine whether vitamin C in the first three days postpartum reduces pulmonary oedema (PE) assessed by lung ultrasound in patients with severe preeclampsia. DESIGN: Randomised, placebo-controlled, double-blind trial. SETTING: Tertiary perinatal centre. POPULATION: Consecutively admitted patients with singleton pregnancies complicated by severe preeclampsia. METHODS: Thirty-four patients received vitamin C (1.5 g/6 h) (n = 17) or placebo (n = 17) at days 1, 2, and 3 postdelivery. Mann-Whitney-U test was used to compare vitamin C vs placebo groups. A p ≤ 0.05 was considered statistically significant. MAIN OUTCOME MEASURES: Lung ultrasound was performed once daily in the first three days following delivery. Echo Comet Score (ECS) on day 1 postdelivery was the primary outcome studied and was obtained using the 28-rib interspaces technique. ECS on days 2 and 3 postdelivery were secondary outcomes. RESULTS: There was no significant difference in ECS on day 1 (median 23 (inter-quartile range (IQR) 21-61) vs 18 (IQR 8-35); p = 0.31). All ultrasound examinations on day 1 were performed within six hours from delivery. On days 2 and 3, ECS was significantly lower in vitamin C group compared to placebo (8 (IQR 3-14) vs 35 (IQR 15-78); p = 0.03 and 5 (IQR 3-10) vs 18 (IQR 18-44); p = 0.04, respectively). CONCLUSION: A single dose of intravenous vitamin C did not reduce PE in postpartum patients with severe preeclampsia on day 1 after delivery. Repeated doses, however, seem to have a delayed effect with a reduction in PE detected on ultrasound on days 2 and 3 following delivery. TRIAL REGISTRATION: This trial is registered at ClinicalTrials.gov: ID NCT03451266 (https://clinicaltrials.gov/ct2/show/NCT03451266?term=NCT03451266&draw=2&rank=1).


Subject(s)
Pre-Eclampsia , Pulmonary Edema , Ascorbic Acid , Double-Blind Method , Female , Humans , Lung , Pre-Eclampsia/drug therapy , Pregnancy , Pulmonary Edema/diagnostic imaging
9.
J Hypertens ; 38(7): 1367-1374, 2020 07.
Article in English | MEDLINE | ID: mdl-32195819

ABSTRACT

OBJECTIVES: In women with severe preeclampsia the period immediately before and early postdelivery carries the greatest risk for cardiac decompensation due to acute changes in loading conditions. The authors aimed to evaluate dynamic changes in hemodynamic and echocardiographic-derived systolic and diastolic function parameters in preeclamptic women compared with healthy controls. METHODS: Thirty women with severe preeclampsia and 30 healthy controls underwent transthoracic echocardiography 1 day before, 1 and 4 days postdelivery. Fluid responsiveness was assessed by passive leg raising. RESULTS: Peak systolic myocardial velocities (s') and global longitudinal strain (GLS) were significantly lower in preeclamptic group compared with controls only postdelivery (s': 7.3 ±â€Š0.8 vs. 8.3 ±â€Š0.9 cm/s, P < 0.001; GLS: -21.4 ±â€Š2.0 vs. -23.0 ±â€Š1.4%, P = 0.027). In addition, significant decrease in s' after delivery was observed only in preeclamptic group (P = 0.004). For diastolic parameters there were differences both before and postdelivery in E/e' ratio (before: 8.4 ±â€Š2.16 vs. 6.7 ±â€Š1.89, P = 0.002; postdelivery: 8.3 ±â€Š1.64 vs. 6.8 ±â€Š1.27, P = 0.003) and mitral e' velocity (before: 11.0 ±â€Š2.39 vs. 12.6 ±â€Š1.86, P = 0.004; postdelivery: 11.1 ±â€Š2.28 vs. 14.0 ±â€Š2.40 cm/s, P < 0.001). Significant increase in left ventricular stroke volume (P = 0.005) and transmitral E velocity (P = 0.003) was observed only in control group, reflecting response to volume load after delivery. Accordingly, only the minority of preeclamptic women were fluid responsive (11 vs. 43%, P = 0.014 between groups). CONCLUSION: Variations in cardiac parameters in healthy women seem to follow changes in loading conditions before and early after delivery. Different pattern in preeclamptic women, however, may be related to subtle myocardial dysfunction, that becomes uncovered with augmented volume load in early postpartum period.


Subject(s)
Diastole , Heart/physiopathology , Pre-Eclampsia/physiopathology , Stroke Volume , Systole , Adult , Cardiomyopathies/physiopathology , Case-Control Studies , Echocardiography , Female , Hemodynamics , Humans , Postpartum Period , Pregnancy , Prospective Studies , Reproducibility of Results , Ventricular Dysfunction, Left , Ventricular Function, Left
12.
Wien Klin Wochenschr ; 130(5-6): 211-219, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29204737

ABSTRACT

BACKGROUND: MitraClip is a percutaneous mitral repair technology increasingly used for high surgical risk patients with primary or secondary mitral regurgitation. We describe initial Slovenian experience with MitraClip and discuss the importance of identifying the suitable candidates for this procedure. METHODS: We retrospectively analyzed the first 10 patients (mean age 75.6 ± 6.9 years, logistic Euroscore 28.4 ± 10.9%) with severe and moderate to severe mitral regurgitation (8 secondary, 1 primary and 1 mixed etiology) who underwent a MitraClip procedure between January 2015 and February 2017. RESULTS: Acute reduction of mitral regurgitation was achieved in all but one patient (90%). There were no periprocedural mortalities and at short to mid-term follow-up (median 12 months, interquartile range 3-15 months). In eight patients improvement of functional class was observed at discharge. No functional improvement was achieved in a patient with advanced ischemic cardiomyopathy, and in a patient with degenerative mitral disease in whom the MitraClip procedure had failed necessitating mitral valve surgery. One patient experienced late leaflet detachment and was effectively managed with a second MitraClip procedure. There were two vascular complications at the access site and one percutaneous closure of an iatrogenic atrial septal defect. CONCLUSION: Our initial experiences with a small number of patients indicate that percutaneous mitral repair with MitraClip is a feasible and safe method in high-risk patients. Special attention should be paid to careful patient selection including detailed echocardiographic evaluation of mitral valve anatomy, technical performance and final result, particularly at the beginning of the learning curve in order to reduce the rate of serious complications.


Subject(s)
Cardiac Catheterization/instrumentation , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Patient Selection , Suture Techniques/instrumentation , Aged , Aged, 80 and over , Equipment Design , Female , Humans , Male , Retrospective Studies , Slovenia , Treatment Outcome
13.
Radiol Oncol ; 52(4): 377-382, 2018 11 26.
Article in English | MEDLINE | ID: mdl-30511937

ABSTRACT

Background There are no data on usefulness of optic nerve sheath diameter (ONSD) as a marker of patient's fluid status in preeclampsia. The objective was to examine potential correlation between ONSD and lung ultrasound estimates of extravascular lung water in severe preeclampsia. Patients and methods Thirty patients with severe preeclampsia were included. Optic and lung ultrasound were performed within 24 hours from delivery. ONSD was measured 3 mm behind the globe. Lung ultrasound Echo Comet Score (ECS) was obtained summing B-lines ("comet tails") in parasternal intercostal spaces bilaterally. Pearson's correlation analysis was used to assess the relationship between ONSD and ECS (p < 0.05 significant). Results Median ONSD was 5.7 mm (range 3.8-7.5 mm). Median ECS value was 19 (range 0-24). Statistically significant correlation was found between ONSD and ECS (r2 = 0.464; p < 0.001). Conclusions Significant correlation between ONSD and ECS suggests optic ultrasound could be used for assessing fluid status and guiding peripartum fluid therapy in patients with severe preeclampsia.


Subject(s)
Intracranial Hypertension/physiopathology , Intracranial Pressure/physiology , Optic Nerve/diagnostic imaging , Pre-Eclampsia/physiopathology , Ultrasonography/methods , Water-Electrolyte Imbalance/physiopathology , Adult , Extravascular Lung Water , Female , Humans , Pregnancy , Prospective Studies , Pulmonary Edema/diagnostic imaging , Pulmonary Edema/physiopathology , Reproducibility of Results
14.
Wien Klin Wochenschr ; 128(13-14): 516-20, 2016 Jul.
Article in English | MEDLINE | ID: mdl-26983954

ABSTRACT

BACKGROUND: Aortic stenosis is a progressive disease. Symptomatic aortic stenosis has a poor prognosis, which is frequently worse than that of a malignant disease. Cancer patients with severe aortic stenosis may be denied for optimal oncologic treatment because of high operative risk and for aortic valve replacement because of the significant comorbidity itself. In patients treated with medical therapy alone, 1-year-mortality exceeds 50 %. CASE REPORT: A 71-year-old woman with well-differentiated, surgically treated, ovarian carcinoma and two relapses treated with chemo- and radiotherapy presented with symptomatic severe aortic stenosis (aortic valve area 0.6 cm(2), mean gradient 60 mmHg). The tumor was in stagnation. She was rejected for surgical valve replacement. We implanted a 29 mm CoreValve aortic prosthesis via transfemoral approach. After the procedure haemodynamic variables remain stable, patient's exertional capacity is excellent. CONCLUSION: Aortic valve replacement improves survival of cancer patients with symptomatic aortic stenosis. Transcatheter aortic valve replacement (TAVI) is a treatment option in inoperable patients and patients at high surgical risk. Symptoms should not be confused for the progression of the malignant disease. In patient selection emphasis should be made on their frailty and futility. Eligible patients must have a life expectancy of at least 1 year. Final decision has to be made by a multidisciplinary heart team. TAVI can reduce treatment risk and facilitate the oncologic treatment.


Subject(s)
Aortic Valve Stenosis/complications , Aortic Valve Stenosis/surgery , Ovarian Neoplasms/complications , Patient Selection , Transcatheter Aortic Valve Replacement/methods , Aged , Female , Heart Valve Prosthesis , Humans , Treatment Outcome
15.
Wien Klin Wochenschr ; 115(3-4): 132-4, 2003 Feb 28.
Article in English | MEDLINE | ID: mdl-12674692

ABSTRACT

Percutaneous coronary revascularization plays an important role in the management of acute coronary syndrome. Unpredictable angiographic findings of severe coronary ectasia and tortuosity may, however, compromise the otherwise high and predictable success rates of this intervention. We report on two patients with acute coronary syndrome in whom difficult anatomy precluded successful percutaneous recanalization of the culprit vessel.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Aneurysm/diagnosis , Coronary Artery Disease/complications , Coronary Disease/diagnosis , Coronary Disease/therapy , Coronary Angiography , Coronary Artery Bypass , Coronary Artery Disease/diagnosis , Coronary Artery Disease/surgery , Coronary Artery Disease/therapy , Coronary Disease/diagnostic imaging , Coronary Disease/surgery , Coronary Thrombosis/etiology , Dilatation, Pathologic/diagnosis , Electrocardiography , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL