Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Prof Inferm ; 74(4): 160-165, 2021.
Article in Italian | MEDLINE | ID: mdl-35363958

ABSTRACT

INTRODUCTION: The handover has relevant implications in terms of patient safety. An effective handover requires the use of a standardized and shared communication tool. AIM: This observational study explored the nursing handover at shift change in order to detect eventual omissions. Furthermore, it investigated the quality perceived by the nurses involved. METHOD: At each shift change, an external observer detected the referred and omitted information by the delivering nurse, through the use of a direct observational grid (modified ISBAR). The percentage of the omitted information was calculated excluding any unforeseen information, not linked to the patient care pathway and detected through the consultation of the nursing record. The quality perceived by the nurses involved was investigated through the use of the Handoff CEX tool. The data was processed through a descriptive and inferential statistical analysis. RESULTS: 256 handovers were observed and 256 nursing records were reviewed. The omissions were detected in 43.17% of the cases. The results highlight a propensity for a prospective approach. A high statistical significance emerges in relation to the modality of handover, the type of patient, the nurse/patients ratio and the number of interruptions. Referring to the perceived quality, 40 Handoff CEX evaluation forms were completed. The results show a more than satisfactory perception. However, the thematic analysis highlights scarcely detailed and dispersive handovers as well as the difficulty to focus on the information to deliver. CONCLUSION: According to the findings of this research, it is necessary to implement a standardized tool which supports the handover process.


Subject(s)
Patient Handoff , Hospitals , Humans , Inpatients , Nurse-Patient Relations , Patient Safety
2.
Diagnostics (Basel) ; 14(4)2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38396398

ABSTRACT

Olfactory dysfunction (OD) is one of the most common symptoms in COVID-19 patients and can impact patients' lives significantly. The aim of this review was to investigate the multifaceted impact of COVID-19 on the olfactory system and to provide an overview of magnetic resonance (MRI) findings and neurocognitive disorders in patients with COVID-19-related OD. Extensive searches were conducted across PubMed, Scopus, and Google Scholar until 5 December 2023. The included articles were 12 observational studies and 1 case report that assess structural changes in olfactory structures, highlighted through MRI, and 10 studies correlating the loss of smell with neurocognitive disorders or mood disorders in COVID-19 patients. MRI findings consistently indicate volumetric abnormalities, altered signal intensity of olfactory bulbs (OBs), and anomalies in the olfactory cortex among COVID-19 patients with persistent OD. The correlation between OD and neurocognitive deficits reveals associations with cognitive impairment, memory deficits, and persistent depressive symptoms. Treatment approaches, including olfactory training and pharmacological interventions, are discussed, emphasizing the need for sustained therapeutic interventions. This review points out several limitations in the current literature while exploring the intricate effects of COVID-19 on OD and its connection to cognitive deficits and mood disorders. The lack of objective olfactory measurements in some studies and potential validity issues in self-reports emphasize the need for cautious interpretation. Our research highlights the critical need for extensive studies with larger samples, proper controls, and objective measurements to deepen our understanding of COVID-19's long-term effects on neurological and olfactory dysfunctions.

3.
J Vasc Access ; 24(6): 1495-1499, 2023 Nov.
Article in English | MEDLINE | ID: mdl-35343297

ABSTRACT

BACKGROUND: COVID-19 patients require frequent arterial blood gas analysis for the assessment of oxygenation status. OBJECTIVE: The main objective of this research is to describe a dedicated protocol developed to standardize the insertion and management of peripheral Arterial Catheters (AC) for on-demand use, in the Emergency Department of "Maggiore" Hospital (Lodi, Italy).This strategy represents a valid alternative to repeated arterial punctures outside the intensive care unit. METHODS: The crucial points of the protocol were defined: vessel selection criteria, device used, technique of insertion, choice of securement and dressing device, and procedures had been created for correct management. RESULTS: During April and December 2020, 50 AC were inserted, two dislocations and one malfunction were observed. No major complications (Catheter Related Bloodstream Infection, thrombosis, bleeding, pseudoaneurysms, hematoma, artery occlusion - even temporary - and skin irritation) were observed. CONCLUSIONS: To the authors knowledge, this is the first article describing the insertion and management of ACs for on-demand utilization outside the intensive care unit. The safe and effective use of this technique could be clinically relevant in patients requiring multiple ABG without need of invasive monitoring; it also allows the reduction of both artery sticks and workload of health care providers. However, clinical studies are needed to confirm the validity of the proposed treatment, especially the use of the most appropriate securement system and the most effective solution for locking catheters.


Subject(s)
Catheterization, Central Venous , Catheterization, Peripheral , Humans , Retrospective Studies , Catheters, Indwelling , Intensive Care Units , Cannula
4.
J Vasc Access ; 23(4): 610-614, 2022 Jul.
Article in English | MEDLINE | ID: mdl-33726584

ABSTRACT

BACKGROUND: The tunneling technique is currently widely used for placement of CVC. Recently, some clinicians have used this technique for peripherally inserted central catheters (PICC), or Midline catheters (MCs). OBJECTIVE: To describe a safe antegrade tunneling technique for PICCs and MCs insertion with a blunt tunneler. METHODS: This retrospective monocentric survey collected ASST Lodi hospital data from January 1st to December 31st, 2019. The indication for PICCs and MCs tunneled implant was to respect the correct vein/catheter ratio or special clinical situation (children, burns, wounds, and wider catheter 5/6 fr). Contraindications included the operator's low skills and severe risk of bleeding (INR > 3; Platelet count <50'000). RESULTS: About 390 PICCs (327 4 fr and 63 5 fr) and 183 MCs were placed. One hundred and sixty-five PICCs (42%) and 110 MCs (60%) were tunneled. Five fr PICCs were more present among tunneled catheters (54/165 [32.7%] vs 9/225 [4%] p < 0.0001). In the majority tunneling was necessary to respect the correct catheter/vein ratio. The exit site was shifted only for four special clinical situations: skin infections (one PICC and two MCs); burns (one MC). No early complication (intraprocedural, major bleeding), catheter related thrombosis, or device fractures occurred. Two catheter-related bloodstream infections (one PICC, one MC), nine dislocations (four PICCs, five MCs), one MC occlusion were recorded. CONCLUSIONS: The antegrade tunneling technique with blunt tunneler of PICCs and MCs is simple, rapid and is regarded as a safe maneuver. More in-depth and future prospective studies are needed to evaluate the impact of tunneling on early and late complications.


Subject(s)
Catheter-Related Infections , Catheterization, Central Venous , Catheterization, Peripheral , Central Venous Catheters , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/methods , Catheters , Child , Humans , Retrospective Studies , Risk Factors
5.
J Vasc Access ; 23(4): 532-537, 2022 Jul.
Article in English | MEDLINE | ID: mdl-33618564

ABSTRACT

BACKGROUND: Venous Access Devices (VADs) are the most used devices in COVID-19 patients. OBJECTIVE: Identify VADs implanted, catheter related thrombosis (CRT), catheter-related bloodstream infection (CRBSI), and accidental remove of VADs in both COVID-19 positive and COVID-19 free patients. Successive analysis was conducted comparing COVID-19 positive patients with COVID-19 free with inverse probability propensity score weights using simple regression to account for these two confounders (peripheral tip as central/peripheral and hospitalization as no/yes). METHODS: This multicenter, retrospective cohort study collected data from seven hospitals in Lombardy during the pandemic period from February 21st to May 31st 2020. RESULTS: A total of 2206 VADs were evaluated, 1107 (50.2%) of which were inserted in COVID-19 patients. In COVID-19 cohort the first choice was Long Peripheral Cannula in 388 patients (35.1%) followed by Midline Catheter in 385 (34.8%). The number of "central tip" VADs inserted in COVID-free inpatients and COVID-19 positive were similar (307 vs 334). We recorded 42 (1.9%) CRT; 32 (79.2%) were observed in COVID-19 patients. A total of 19 CRBSI were diagnosed; 15 (78.95%) were observed in COVID-19. Accidental removals were the more represented complication with 123 cases, 85 (69.1%) of them were in COVID-19. COVID-19 significantly predicted occurrence of CRT (OR = 2.00(1.85-5.03); p < 0.001), CRSB (OR = 3.82(1.82-8.97); p < 0.001), and Accidental Removal (OR = 2.39(1.80-3.20); p < 0.001) in our propensity score weighted models. CONCLUSIONS: CRT, CRBSI, and accidental removal are significantly more frequent in COVID-19 patients. Accidental removals are the principal complication, for this reason, the use of subcutaneously anchored securement is recommended for a shorter period than usual.


Subject(s)
COVID-19 , Catheter-Related Infections , Catheterization, Central Venous , Central Venous Catheters , COVID-19/epidemiology , Catheter-Related Infections/epidemiology , Catheterization, Central Venous/adverse effects , Catheters , Humans , Retrospective Studies
6.
J Patient Saf ; 17(3): e143-e148, 2021 04 01.
Article in English | MEDLINE | ID: mdl-28333697

ABSTRACT

OBJECTIVE: Medication errors are one of the leading causes of patient harms. Medication reconciliation is a fundamental process that to be effective, it should be embraced during each single care transition. Our objectives were to investigate current medication reconciliation practices in the 2 Fondazione Toscana Gabriele Monasterio hospitals and comprehensively assess the quality of medication reconciliation practices between inpatient and outpatient care by analyzing the medication patterns 6 months before admission, during hospitalization, and 9 months after discharge for a selected group of patients with cardiovascular diseases. METHODS: A retrospective observational study was conducted in the Cardiothoracic Department of the Fondazione Toscana Gabriele Monasterio hospitals. Medication history was reviewed for all the patients admitted from and discharged to the community, from January to March 2013. Patients were excluded if they had less than 4 drugs or less than 2 drugs for cardiovascular system in their prescription list at admission or if they died during follow-up. We selected 714 patients, and we obtained the clinical charts and all drug prescriptions collected during patients' hospitalization by the electronic clinical recording system. We also analyzed the list of prescriptions of this sample of patients, from 6 months before admission to 9 months after discharge, extracted from the regional prescription registry. In the resulting sample, prescriptions were analyzed to assess unintentional discrepancies. RESULTS: The study included 298 patients (mean age, 71.2 years), according to the inclusion and exclusion criteria. Among 14,573 prescriptions analyzed, we found 4363 discrepancies (14.6 discrepancies per patient). Among these discrepancies, 1310 were classified as unintentional (4.4 discrepancies per patient). Among unintentional discrepancies, only 63 (4.8%) took place during hospitalization. Although at the hospital-home interface, 33.1% of unintentional discrepancies were detected through the comparison between the patients' declared therapy and the previous medication consumption and 62.1% were identified in the comparison between the prescription at the discharge and the following medication pattern at home. CONCLUSIONS: Medication errors have important implications for patient safety, and their identification is a main target for improving clinical practice. The comparison between the medication patterns acquired through the regional prescription registry before and after hospitalization outlined critical touchpoint in the current medication reconciliation process, calling for the definition of shared medication reconciliation standards between hospitals and primary care services to minimize medication discrepancies and enhance patient safety.


Subject(s)
Medication Reconciliation , Patient Admission , Aged , Drug Prescriptions , Hospitalization , Hospitals, University , Humans , Retrospective Studies
7.
Eur Heart J Cardiovasc Imaging ; 21(8): 896-905, 2020 08 01.
Article in English | MEDLINE | ID: mdl-32259844

ABSTRACT

AIMS: To obtain the normal range for 2D echocardiographic (2DE) measurements of left ventricular (LV) layer-specific strain from a large group of healthy volunteers of both genders over a wide range of ages. METHODS AND RESULTS: A total of 287 (109 men, mean age: 46 ± 14 years) healthy subjects were enrolled at 22 collaborating institutions of the EACVI Normal Reference Ranges for Echocardiography (NORRE) study. Layer-specific strain was analysed from the apical two-, three-, and four-chamber views using 2DE software. The lowest values of layer-specific strain calculated as ±1.96 standard deviations from the mean were -15.0% in men and -15.6% in women for epicardial strain, -16.8% and -17.7% for mid-myocardial strain, and -18.7% and -19.9% for endocardial strain, respectively. Basal-epicardial and mid-myocardial strain decreased with age in women (epicardial; P = 0.008, mid-myocardial; P = 0.003) and correlated with age (epicardial; r = -0.20, P = 0.007, mid-myocardial; r = -0.21, P = 0.006, endocardial; r = -0.23, P = 0.002), whereas apical-epicardial, mid-myocardial strain increased with the age in women (epicardial; P = 0.006, mid-myocardial; P = 0.03) and correlated with age (epicardial; r = 0.16, P = 0.04). End/Epi ratio at the apex was higher than at the middle and basal levels of LV in men (apex; 1.6 ± 0.2, middle; 1.2 ± 0.1, base 1.1 ± 0.1) and women (apex; 1.6 ± 0.1, middle; 1.1 ± 0.1, base 1.2 ± 0.1). CONCLUSION: The NORRE study provides useful 2DE reference ranges for novel indices of layer-specific strain.


Subject(s)
Echocardiography , Heart Ventricles , Adult , Endocardium , Female , Heart Ventricles/diagnostic imaging , Humans , Male , Middle Aged , Myocardium , Reference Values , Ventricular Function, Left
8.
Eur Heart J Cardiovasc Imaging ; 21(5): 533-541, 2020 05 01.
Article in English | MEDLINE | ID: mdl-31408147

ABSTRACT

AIMS: The present study sought to evaluate the correlation between indices of non-invasive myocardial work (MW) and left ventricle (LV) size, traditional and advanced parameters of LV systolic and diastolic function by 2D echocardiography (2DE). METHODS AND RESULTS: A total of 226 (85 men, mean age: 45 ± 13 years) healthy subjects were enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. Global work index (GWI), global constructive work (GCW), global work waste (GWW), and global work efficiency (GWE) were estimated from LV pressure-strain loops using custom software. Peak LV pressure was estimated non-invasively from brachial artery cuff pressure. LV size, parameters of systolic and diastolic function and ventricular-arterial coupling were measured by echocardiography. As advanced indices of myocardial performance, global longitudinal strain (GLS), global circumferential strain (GCS), and global radial strain (GRS) were obtained. On multivariable analysis, GWI was significantly correlated with GLS (standardized beta-coefficient = -0.23, P < 0.001), ejection fraction (EF) (standardized beta-coefficient = 0.15, P = 0.02), systolic blood pressure (SBP) (standardized beta-coefficient = 0.56, P < 0.001) and GRS (standardized beta-coefficient = 0.19, P = 0.004), while GCW was correlated with GLS (standardized beta-coefficient = -0.55, P < 0.001), SBP (standardized beta-coefficient = 0.71, P < 0.001), GRS (standardized beta-coefficient = 0.11, P = 0.02), and GCS (standardized beta-coefficient = -0.10, P = 0.01). GWE was directly correlated with EF and inversely correlated with Tei index (standardized beta-coefficient = 0.18, P = 0.009 and standardized beta-coefficient = -0.20, P = 0.004, respectively), the opposite occurred for GWW (standardized beta-coefficient =--0.14, P = 0.03 and standardized beta-coefficient = 0.17, P = 0.01, respectively). CONCLUSION: The non-invasive MW indices show a good correlation with traditional 2DE parameters of myocardial systolic function and myocardial strain.


Subject(s)
Ventricular Dysfunction, Left , Ventricular Function, Left , Adult , Diastole , Echocardiography , Humans , Male , Middle Aged , Stroke Volume , Systole , Ventricular Dysfunction, Left/diagnostic imaging
9.
Eur Heart J Cardiovasc Imaging ; 20(5): 582-590, 2019 May 01.
Article in English | MEDLINE | ID: mdl-30590562

ABSTRACT

AIMS: To obtain the normal ranges for 2D echocardiographic (2DE) indices of myocardial work (MW) from a large group of healthy volunteers over a wide range of ages and gender. METHODS AND RESULTS: A total of 226 (85 men, mean age: 45 ± 13 years) healthy subjects were enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. Global work index (GWI), global constructive work (GCW), global work waste (GWW), and global work efficiency (GWE) were estimated from left ventricle (LV) pressure-strain loops. Peak LV systolic pressure was non-invasively derived from brachial artery cuff pressure. The lowest values of MW indices in men and women were 1270 mmHg% and 1310 mmHg% for GWI, 1650 mmHg% and 1544 mmHg% for GCW, and 90% and 91% for GWE, respectively. The highest value for GWW was 238 mmHg% in men and 239 mmHg% in women. Men had significant lower values of GWE and higher values of GWW. GWI and GCW significantly increased with age in women. CONCLUSION: The NORRE study provides useful 2DE reference ranges for novel indices of non-invasive MW.


Subject(s)
Echocardiography/methods , Heart Function Tests , Europe , Female , Humans , Male , Middle Aged , Prospective Studies , Reference Values
10.
Eur Heart J Cardiovasc Imaging ; 19(6): 630-638, 2018 06 01.
Article in English | MEDLINE | ID: mdl-29529180

ABSTRACT

Aims: To obtain the normal ranges for echocardiographic measurements of left atrial (LA) function from a large group of healthy volunteers accounting for age and gender. Methods and results: A total of 371 (median age 45 years) healthy subjects were enrolled at 22 collaborating institutions collaborating in the Normal Reference Ranges for Echocardiography (NORRE) study of the European Association of Cardiovascular Imaging (EACVI). Left atrial data sets were analysed with a vendor-independent software (VIS) package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire data sets. The lowest expected values of LA function were 26.1%, 48.7%, and 41.4% for left atrial strain (LAS), 2D left atrial emptying fraction (LAEF), and 3D LAEF (reservoir function); 7.7%, 24.2%, and -0.53/s for LAS-active, LAEF-active, and LA strain rate during LA contraction (SRa) (pump function) and 12.0% and 21.6% for LAS-passive and LAEF-passive (conduit function). Left atrial reservoir and conduit function were decreased with age while pump function was increased. All indices of reservoir function and all LA strains had no difference in both gender and vendor. However, inter-vendor differences were observed in LA SRa despite the use of VIS. Conclusion: The NORRE study provides contemporary, applicable echocardiographic reference ranges for LA function. Our data highlight the importance of age-specific reference values for LA functions.


Subject(s)
Atrial Function, Left/physiology , Echocardiography/methods , Heart Atria/diagnostic imaging , Image Processing, Computer-Assisted/methods , Adult , Age Factors , Cohort Studies , Echocardiography, Three-Dimensional/methods , Female , Healthy Volunteers , Humans , Linear Models , Male , Middle Aged , Multivariate Analysis , Observer Variation , Reference Standards , Sex Factors , Statistics, Nonparametric
12.
Eur Heart J Cardiovasc Imaging ; 18(2): 167-179, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27044913

ABSTRACT

AIMS: To report normal reference ranges for echocardiographic dimensions of the proximal aorta obtained in a large group of healthy volunteers recruited using state-of-the-art cardiac ultrasound equipment, considering different measurement conventions, and taking into account gender, age, and body size of individuals. METHODS AND RESULTS: A total of 704 (mean age: 46.0 ± 13.5 years) healthy volunteers (310 men and 394 women) were prospectively recruited from the collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. A comprehensive echocardiographic examination was obtained in all subjects following pre-defined protocols. Aortic dimensions were obtained in systole and diastole, following both the leading-edge to leading-edge and the inner-edge to inner-edge conventions. Diameters were measured at four levels: ventricular-arterial junction, sinuses of Valsalva, sino-tubular junction, and proximal tubular ascending aorta. Measures of aortic root in the short-axis view following the orientation of each of the three sinuses were also performed. Men had significantly larger body sizes when compared with women, and showed larger aortic dimensions independently of the measurement method used. Dimensions indexed by height and body surface area are provided, and stratification by age ranges is also displayed. In multivariable analysis, the independent predictors of aortic dimensions were age, gender, and height or body surface area. CONCLUSION: The NORRE study provides normal values of proximal aorta dimensions as assessed by echocardiography. Reference ranges for different anatomical levels using different (i) measurement conventions and (ii) at different times of the cardiac cycle (i.e. mid-systole and end-diastole) are provided. Age, gender, and body size were significant determinants of aortic dimensions.


Subject(s)
Aorta, Thoracic/anatomy & histology , Aorta, Thoracic/diagnostic imaging , Diastole/physiology , Echocardiography , Adult , Age Factors , Analysis of Variance , Cohort Studies , Europe , Female , Healthy Volunteers , Humans , Linear Models , Male , Middle Aged , Multivariate Analysis , Prospective Studies , Reference Values , Sex Factors , Systole/physiology , Young Adult
13.
Eur Heart J Cardiovasc Imaging ; 18(8): 833-840, 2017 May 01.
Article in English | MEDLINE | ID: mdl-28637227

ABSTRACT

AIMS: To obtain the normal ranges for 2D echocardiographic (2DE) measurements of left ventricular (LV) strain from a large group of healthy volunteers accounting for age and gender. METHODS AND RESULTS: A total of 549 (mean age: 45.6 ± 13.3 years) healthy subjects were enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. 2DE data sets have been analysed with a vendor-independent software package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire the data sets. The lowest expected values of LV strains and twist calculated as ± 1.96 standard deviations from the mean were -16.7% in men and -17.8% in women for longitudinal strain, -22.3% and -23.6% for circumferential strain, 20.6% and 21.5% for radial strain, and 2.2 degrees and 1.9 degrees for twist, respectively. In multivariable analysis, longitudinal strain decreased with age whereas the opposite occurred with circumferential and radial strain. Male gender was associated with lower strain for longitudinal, circumferential, and radial strain. Inter-vendor differences were observed for circumferential and radial strain despite the use of vendor-independent software. Importantly, no intervendor differences were noted in longitudinal strain. CONCLUSION: The NORRE study provides contemporary, applicable 2D echocardiographic reference ranges for LV longitudinal, radial, and circumferential strain. Our data highlight the importance of age- and gender-specific reference values for LV strain.


Subject(s)
Echocardiography/methods , Heart Ventricles/diagnostic imaging , Image Processing, Computer-Assisted , Ventricular Function, Left/physiology , Adult , Age Factors , Europe , Female , Healthy Volunteers , Humans , Linear Models , Male , Middle Aged , Multivariate Analysis , Observer Variation , Reference Values , Sex Factors
14.
Eur Heart J Cardiovasc Imaging ; 18(4): 475-483, 2017 Apr 01.
Article in English | MEDLINE | ID: mdl-28329230

ABSTRACT

AIM: To obtain the normal ranges for 3D echocardiography (3DE) measurement of left ventricular (LV) volumes, function, and strain from a large group of healthy volunteers. METHODS AND RESULTS: A total of 440 (mean age: 45 ± 13 years) out of the 734 healthy subjects enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study had good-quality 3DE data sets that have been analysed with a vendor-independent software package allowing homogeneous measurements regardless of the echocardiographic machine used to acquire the data sets. Upper limits of LV end-diastolic and end-systolic volumes were larger in men (97 and 42 mL/m2) than in women (82 and 35 mL/m2; P < 0.0001). Conversely, lower limits of LV ejection fraction were higher in women than in men (51% vs. 50%; P < 0.01). Similarly, all strain components were higher in women than in men. Lower range was -18.6% in men and -19.5% in women for 3D longitudinal strain, -27.0% and -27.6% for 3D circumferential strain, -33.2% and -34.4% for 3D tangential strain and 38.8% and 40.7% for 3D radial strain, respectively. LV volumes decreased with age in both genders (P < 0.0001), whereas LV ejection fraction increased with age only in men. Among 3DE LV strain components, the only one, which did not change with age was longitudinal strain. CONCLUSION: The NORRE study provides applicable 3D echocardiographic reference ranges for LV function assessment. Our data highlight the importance of age- and gender-specific reference values for both LV volumes and strain.


Subject(s)
Cardiac Volume/physiology , Echocardiography, Three-Dimensional , Heart Ventricles/diagnostic imaging , Ventricular Function, Left/physiology , Adult , Aged , Female , Healthy Volunteers , Humans , Male , Middle Aged , Reference Values , Young Adult
15.
Eur Heart J Cardiovasc Imaging ; 16(9): 1031-41, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25896355

ABSTRACT

AIMS: Reference values for Doppler parameters according to age and gender are recommended for the assessment of heart physiology, specifically for left ventricular (LV) diastolic function. In this study, we report normal reference ranges for Doppler parameters obtained in a large group of healthy volunteers. Echocardiographic data were acquired using state-of-the-art cardiac ultrasound equipment following Doppler acquisition and measurement protocols approved by the European Association of Cardiovascular Imaging. METHODS AND RESULTS: A total of 449 (mean age: 45.8 ± 13.7 years) healthy volunteers (198 men and 251 women) were enrolled at the collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. A comprehensive echocardiographic examination was obtained from all subjects following predefined protocols. The majority of the Doppler diastolic parameters (e', E/e') as well as right ventricle systolic s' wave velocity were similar in men and women. Left ventricle s' wave velocity was higher in men than in women. E wave and e' were higher in younger subjects and decreased progressively in the older ones. E/e' ratio increased with ageing. Septal e' <8 cm/s was present in 19.7% of the subjects in the 40-60 year group and in 55% of those in the ≥60 year group. However, the cut-off value of average E/e' or lateral E/e' remained <15 or 13, respectively, in the majority of patients. CONCLUSION: The NORRE study provides the reference values for the most useful Doppler parameters in the evaluation of heart physiology. These data highlight the need of using age-specific reference values especially for the diagnosis of LV systolic and diastolic dysfunction and for the estimation of LV filling pressures.


Subject(s)
Aging/physiology , Echocardiography, Doppler/methods , Heart Ventricles/diagnostic imaging , Ventricular Function, Left/physiology , Adult , Age Factors , Aged , Cohort Studies , Diastole/physiology , Europe , Female , Healthy Volunteers , Humans , Male , Middle Aged , Reference Values , Sex Factors , Systole/physiology , Young Adult
16.
Eur Heart J Cardiovasc Imaging ; 15(6): 680-90, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24451180

ABSTRACT

AIMS: Availability of normative reference values for cardiac chamber quantitation is a prerequisite for accurate clinical application of echocardiography. In this study, we report normal reference ranges for cardiac chambers size obtained in a large group of healthy volunteers accounting for gender and age. Echocardiographic data were acquired using state-of-the-art cardiac ultrasound equipment following chamber quantitation protocols approved by the European Association of Cardiovascular Imaging. METHODS: A total of 734 (mean age: 45.8 ± 13.3 years) healthy volunteers (320 men and 414 women) were enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. A comprehensive echocardiographic examination was performed on all subjects following pre-defined protocols. There were no gender differences in age or cholesterol levels. Compared with men, women had significantly smaller body surface areas, and lower blood pressure. Quality of echocardiographic data sets was good to excellent in the majority of patients. Upper and lower reference limits were higher in men than in women. The reference values varied with age. These age-related changes persisted for most parameters after normalization for the body surface area. CONCLUSION: The NORRE study provides useful two-dimensional echocardiographic reference ranges for cardiac chamber quantification. These data highlight the need for body size normalization that should be performed together with age-and gender-specific assessment for the most echocardiographic parameters.


Subject(s)
Echocardiography/methods , Heart Atria/diagnostic imaging , Heart Ventricles/diagnostic imaging , Adult , Age Factors , Aged , Cohort Studies , Female , Heart Atria/anatomy & histology , Heart Ventricles/anatomy & histology , Humans , Male , Middle Aged , Observer Variation , Reference Values , Reproducibility of Results , Risk Assessment , Sex Factors , Stroke Volume/physiology , Young Adult
17.
Eur Heart J Cardiovasc Imaging ; 14(4): 303-8, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23376837

ABSTRACT

BACKGROUND: Availability of normative reference values for cardiac chamber dimensions, volumes, mass, and function is a prerequisite for the accurate application of echocardiography for both clinical and research purposes. However, due to the lack of consistency in current echocardiographic 'reference values', their use for clinical decision-making remains questionable. AIMS: The aim of the 'Normal Reference Ranges for Echocardiography Study (NORRE Study)' is to obtain a set of 'normal values' for cardiac chamber geometry and function in a large cohort of healthy Caucasian individuals aged over a wide range of ages (25-75 years) using both conventional and advanced echocardiographic techniques. METHODS: The NORRE Study is a large prospective, observational multicentre study in which transthoracic echocardiographic studies will be acquired in 22 laboratories accredited by the European Association of Cardiovascular Imaging and in one laboratory in the USA accredited by ICAEL. The final sample size has been estimated in 1100 normal subjects in whom M-mode, 2D, and 3D imaging, colour Doppler, pulsed-wave Doppler, pulsed-wave tissue Doppler, and colour tissue Doppler imaging data will be obtained. All studies will be sent to a central echocardiographic core laboratory for quantitative analysis. Multiple studies will be performed for reproducibility analysis. CONCLUSION: After completion of the NORRE Study, uniform reference limits according to age, gender, and anthropometric parameters will be available to standardize the quantitative interpretation of echocardiography.


Subject(s)
Echocardiography, Doppler/methods , Heart Ventricles/diagnostic imaging , Ventricular Function, Left/physiology , Adult , Age Factors , Aged , Anthropometry , Cohort Studies , Echocardiography, Doppler, Pulsed , Europe , Female , Heart Ventricles/anatomy & histology , Humans , Male , Middle Aged , Prospective Studies , Reference Standards , Sensitivity and Specificity , Sex Factors , Stroke Volume/physiology
SELECTION OF CITATIONS
SEARCH DETAIL