Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 52
Filter
Add more filters

Publication year range
1.
Cardiovasc Diabetol ; 21(1): 246, 2022 11 16.
Article in English | MEDLINE | ID: mdl-36384656

ABSTRACT

BACKGROUND: Diabetes Mellitus (DM) affects a third of patients with symptomatic severe aortic valve stenosis undergoing transcatheter aortic valve implantation (TAVI). DM is a well-known risk factor for cardiac surgery, but its prognostic impact in TAVI patients remains controversial. This study aimed to evaluate outcomes in diabetic patients undergoing TAVI. METHODS: This multicentre registry includes data of > 12,000 patients undergoing transfemoral TAVI. We assessed baseline patient characteristics and clinical outcomes in patients with DM and without DM. Clinical outcomes were defined by the second valve academic research consortium. Propensity score matching was applied to minimize potential confounding. RESULTS: Of the 11,440 patients included, 31% (n = 3550) had DM and 69% (n = 7890) did not have DM. Diabetic patients were younger but had an overall worse cardiovascular risk profile than non-diabetic patients. All-cause mortality rates were comparable at 30 days (4.5% vs. 4.9%, RR 0.9, 95%CI 0.8-1.1, p = 0.43) and at one year (17.5% vs. 17.4%, RR 1.0, 95%CI 0.9-1.1, p = 0.86) in the unmatched population. Propensity score matching obtained 3281 patient-pairs. Also in the matched population, mortality rates were comparable at 30 days (4.7% vs. 4.3%, RR 1.1, 95%CI 0.9-1.4, p = 0.38) and one year (17.3% vs. 16.2%, RR 1.1, 95%CI 0.9-1.2, p = 0.37). Other clinical outcomes including stroke, major bleeding, myocardial infarction and permanent pacemaker implantation, were comparable between patients with DM and without DM. Insulin treated diabetics (n = 314) showed a trend to higher mortality compared with non-insulin treated diabetics (n = 701, Hazard Ratio 1.5, 95%CI 0.9-2.3, p = 0.08). EuroSCORE II was the most accurate risk score and underestimated 30-day mortality with an observed-expected ratio of 1.15 in DM patients, STS-PROM overestimated actual mortality with a ratio of 0.77 and Logistic EuroSCORE with 0.35. CONCLUSION: DM was not associated with mortality during the first year after TAVI. DM patients undergoing TAVI had low rates of mortality and other adverse clinical outcomes, comparable to non-DM TAVI patients. Our results underscore the safety of TAVI treatment in DM patients. TRIAL REGISTRATION: The study is registered at clinicaltrials.gov (NCT03588247).


Subject(s)
Aortic Valve Stenosis , Diabetes Mellitus , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Diabetes Mellitus/diagnosis , Diabetes Mellitus/epidemiology , Diabetes Mellitus/etiology , Propensity Score , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Multicenter Studies as Topic , Registries
2.
Catheter Cardiovasc Interv ; 98(3): E370-E378, 2021 09.
Article in English | MEDLINE | ID: mdl-33904638

ABSTRACT

OBJECTIVES: We aimed to explore angiographic patterns and in-hospital outcomes of patients with concomitant coronavirus disease-19 (COVID-19) and myocardial infarction (MI). BACKGROUND: Patients with COVID-19 may experience MI during the course of the viral infection. However, this association is currently poorly understood. METHODS: This is a multicenter prospective study of consecutive patients with concomitant COVID-19 and MI who underwent coronary angiography. Quantitative and qualitative coronary angiography were analyzed by two observers in an independent core lab. RESULTS: A total of 152 patients were included, of whom 142 (93.4%) had COVID-19 diagnosis confirmation. The median time between symptom onset and hospital admission was 5 (1-10) days. A total of 83 (54.6%) patients presented with ST-elevation MI. The median angiographic Syntax score was 16 (9.0-25.3) and 69.0% had multi-vessel disease. At least one complex lesion was found in 73.0% of patients, 51.3% had a thrombus containing lesion, and 57.9% had myocardial blush grades 0/1. The overall in-hospital mortality was 23.7%. ST-segment elevation MI presentation and baseline myocardial blush grades 0 or 1 were independently associated with a higher risk of death (HR 2.75, 95%CI 1.30-5.80 and HR 3.73, 95%CI 1.61-8.61, respectively). CONCLUSIONS: Patients who have a MI in the context of ongoing COVID-19 mostly present complex coronary morphologies, implying a background of prior atherosclerotic disease superimposed on a thrombotic milieu. The in-hospital prognosis is poor with a markedly high mortality, prompting further investigation to better clarify this newly described condition.


Subject(s)
COVID-19 , Myocardial Infarction , Percutaneous Coronary Intervention , COVID-19 Testing , Coronary Angiography , Hospital Mortality , Humans , Myocardial Infarction/diagnostic imaging , Prospective Studies , SARS-CoV-2 , Treatment Outcome
3.
Catheter Cardiovasc Interv ; 96(5): 1046-1055, 2020 11.
Article in English | MEDLINE | ID: mdl-31990453

ABSTRACT

OBJECTIVES: To report clinical, angiographic characteristics, outcomes, and predictors of unsuccessful procedures in patients who underwent chronic total occlusion (CTO) percutaneous coronary interventions (PCI) in Latin America. BACKGROUND: CTO PCI has been increasingly performed worldwide, but there is a lack of information in this region. METHODS: An international multicenter registry was developed to collect data on CTO PCI performed in centers in Latin America. Patient, angiographic, procedural and outcome data were evaluated. Predictors of unsuccessful procedures were assessed by multivariable analysis. RESULTS: We have included data related to 1,040 CTO PCIs performed in seven countries in Latin America (Argentina, Brazil, Chile, Colombia, Ecuador, Mexico, and Puerto Rico). The mean age was 64 ± 10 years, and CTO PCI was performed mainly for angina control (81%) or treatment of a large ischemic area (30%). Overall technical success rate was 82.5%, and it was achieved with antegrade wire escalation in 81%, antegrade dissection/re-entry in 8% and with retrograde techniques in 11% of the successful procedures. Multivariable analysis identified moderate/severe calcification, a blunt proximal cap and a previous attempt as independent predictors of unsuccessful procedures. In-hospital major adverse cardiovascular events (MACE) occurred in 3.1% of the cases, death in 1% and cardiac tamponade in 0.9% CONCLUSIONS: CTO PCI in Latin America has been performed mainly for ischemia relief. Procedures were associated with a success rate above 80% and low incidence of MACE. Predictors of unsuccessful procedures were similar to those previously reported in the literature.


Subject(s)
Coronary Occlusion/therapy , Percutaneous Coronary Intervention , Aged , Chronic Disease , Coronary Angiography , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/mortality , Female , Hospital Mortality , Humans , Latin America , Male , Middle Aged , Myocardial Infarction/mortality , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Registries , Risk Assessment , Risk Factors , Stroke/mortality , Time Factors , Treatment Outcome
4.
Eur Heart J ; 40(5): 456-465, 2019 02 01.
Article in English | MEDLINE | ID: mdl-30590565

ABSTRACT

Aims: The aim of this study was to compare clinical outcomes of patients undergoing transfemoral transcatheter aortic valve implantation (TAVI) with balloon-expandable (BE) valves vs. self-expandable (SE) valves. Transcatheter aortic valve implantation is a minimally invasive and lifesaving treatment in patients with aortic valve stenosis. Even though BE-valves and SE-valves are both commonly used on a large scale, adequately sized trials comparing clinical outcomes in patients with severe aortic valve stenosis treated with BE-valves compared with SE-valves are lacking. Methods and results: In this CENTER-collaboration, data from 10 registries or clinical trials, selected through a systematic search, were pooled and analysed. Propensity score methodology was used to reduce treatment selection bias and potential confounding. The primary endpoints were mortality and stroke at 30 days follow-up in patients treated with BE-valves compared with SE-valves. Secondary endpoints included clinical outcomes, e.g. bleeding during hospital admission. All outcomes were split for early-generation BE-valves compared with early-generation SE-valves and new-generation BE-valves with new-generation SE-valves. The overall patient population (N = 12 381) included 6239 patients undergoing TAVI with BE-valves and 6142 patients with SE-valves. The propensity matched population had a mean age of 81 ± 7 years and a median STS-PROM score or 6.5% [interquartile range (IQR) 4.0-13.0%]. At 30-day follow-up, the mortality rate was not statistically different in patients undergoing TAVI with BE-valves compared with SE-valves [BE: 5.3% vs. SE: 6.2%, relative risk (RR) 0.9; 95% confidence interval (CI) 0.7-1.0, P = 0.10]. Stroke occurred less frequently in patients treated with BE-valves (BE: 1.9% vs. SE: 2.6%, RR 0.7; 95% CI 0.5-1.0, P = 0.03). Also, patients treated with BE-valves had a three-fold lower risk of requiring pacemaker implantation (BE: 7.8% vs. SE: 20.3%, RR 0.4; 95% CI 0.3-0.4, P < 0.001). In contrast, patients treated with new-generation BE-valves more frequently experienced major and life-threatening bleedings compared with new-generation SE-valves (BE: 4.8% vs. SE: 2.1%, RR 2.3; 95% CI 1.6-3.3, P < 0.001). Conclusion: In this study, which is the largest study to compare valve types in TAVI, we demonstrated that the incidence of stroke and pacemaker implantation was lower in patients undergoing transfemoral TAVI with BE-valves compared with SE-valves. In contrast, patients treated with new-generation BE-valves more often suffered from major or life-threatening bleedings than patients with new-generation SE-valves. Mortality at 30-days was not statistically different in patients treated with BE-valves compared with SE-valves. This study was a propensity-matched analysis generated from observational data, accordingly current outcomes will have to be confirmed in a large scale randomized controlled trial.


Subject(s)
Aortic Valve Stenosis/surgery , Heart Valve Prosthesis , Pacemaker, Artificial/statistics & numerical data , Prosthesis Design , Stroke/epidemiology , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/surgery , Conversion to Open Surgery/statistics & numerical data , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Male , Observational Studies as Topic , Postoperative Complications/epidemiology , Postoperative Complications/mortality , Propensity Score , Registries , Stroke/etiology , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/mortality
5.
Catheter Cardiovasc Interv ; 92(5): 945-953, 2018 11 01.
Article in English | MEDLINE | ID: mdl-29520970

ABSTRACT

OBJECTIVES: To explore the rate, the determinants of success, and the hemodynamic impact of balloon postdilatation (BPD) of self-expanding transcatheter heart valves (SE-THVs) BACKGROUND: BPD is commonly used to optimize valve expansion and reduce paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI) without clearly knowing its hemodynamic benefits. METHODS: Patients (n = 307) who received a SE-THV were stratified according to whether a BPD was performed or not. Patients who received BPD were stratified according to the severity of PVL remaining after BPD into two groups: Successful BPD (≤mild PVL + BPD) and Failed BPD (moderate-severe PVL + BPD). RESULTS: BPD was performed in 121 patients (39.4%) and was successful in 106 patients (87.6% of attempts). A ratio of the postdilatation balloon diameter to the annulus diameter ≤0.95 was an independent predictor of BPD failure (OR: 10.72 [2.02-56.76], P = .005). Peak transvalvular pressure gradient (PG) was lower in the Successful BPD group (14[12-22] mm Hg) than in the Failed BPD group (18[16-23] mm Hg, P = .029), and did not rise in either group during follow-up (median [IQR], 364[161-739] days). CONCLUSION: BPD was performed in 39% of patients who received a SE-THV, and was successful in the majority of attempts. BPD failure was more likely in patients with a small postdilatation balloon-to-annulus diameter ratio. Effective BPD improved THV hemodynamic performance, and this was maintained in the intermediate-term post-TAVI.


Subject(s)
Aortic Valve Insufficiency/prevention & control , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Balloon Valvuloplasty , Heart Valve Prosthesis , Hemodynamics , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/physiopathology , Balloon Valvuloplasty/adverse effects , Brazil , Female , Humans , Male , Prosthesis Design , Recovery of Function , Registries , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
6.
Catheter Cardiovasc Interv ; 90(4): 650-659, 2017 Oct 01.
Article in English | MEDLINE | ID: mdl-28109043

ABSTRACT

OBJECTIVES: We sought to investigate a new angiographic method for aortic regurgitation (AR) severity assessment in the setting of transcatheter aortic valve implantation (TAVI). BACKGROUND: AR after TAVI is common but challenging to quantitate, especially in the cath-lab. METHODS: In 228 patients, AR was quantitated before and after TAVI by echocardiography and by video-densitometric analysis of aortograms. Contrast time-density curves for the aortic root (the reference region) and the left ventricular outflow tract, LVOT were generated. LVOT-AR was calculated as the area under the curve of the LVOT as a fraction of the area under the curve of the reference region. RESULTS: LVOT-AR was 0.10 ± 0.08, 0.13 ± 0.10 and 0.28 ± 0.14 in none-trace, mild and moderate-severe post-TAVI AR as defined by echocardiography (P < 0.001) and a cutpoint of >0.17 corresponded to moderate-severe AR on echocardiography (area under the curve = 0.84). At follow-up (median, 496 days), patients with LVOT-AR ≤ 0.17 showed a significant reduction of LV mass index (LVMi; 121 [95-148] vs. 140 [112-169] g/m2 , P = 0.009) and the prevalence of LV hypertrophy (LVH; 64 vs. 88%, P = 0.001) compared to baseline. In patients with LVOT-AR > 0.17, LVMi (149 [121-178] vs. 166 [144-188] g/m2 , P = 0.14) and the prevalence of LVH (74 vs. 87%, P = 0.23) did not show a significant change. Compared to patients with LVOT-AR ≤ 0.17, those with LVOT-AR > 0.17 had an increased 30-day (16.4% vs. 7.1%, P = 0.035) and one year mortality (32.9 vs. 14.2%, log rank P value = 0.001; HR: 2.690 [1.461-4.953], P = 0.001). CONCLUSIONS: LVOT-AR > 0.17 corresponds to greater than mild AR as defined by echocardiography and predicts impaired LV reverse remodeling and increased early and midterm mortality after TAVI. © 2017 Wiley Periodicals, Inc.


Subject(s)
Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve/surgery , Aortography/methods , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/physiopathology , Area Under Curve , Brazil , Densitometry , Echocardiography, Doppler, Color , Female , Humans , Male , Predictive Value of Tests , ROC Curve , Registries , Reproducibility of Results , Retrospective Studies , Severity of Illness Index , Treatment Outcome
8.
JAMA ; 316(10): 1083-92, 2016 Sep 13.
Article in English | MEDLINE | ID: mdl-27623462

ABSTRACT

IMPORTANCE: Limited data exist on clinical characteristics and outcomes of patients who had infective endocarditis after undergoing transcatheter aortic valve replacement (TAVR). OBJECTIVE: To determine the associated factors, clinical characteristics, and outcomes of patients who had infective endocarditis after TAVR. DESIGN, SETTING, AND PARTICIPANTS: The Infectious Endocarditis after TAVR International Registry included patients with definite infective endocarditis after TAVR from 47 centers from Europe, North America, and South America between June 2005 and October 2015. EXPOSURE: Transcatheter aortic valve replacement for incidence of infective endocarditis and infective endocarditis for in-hospital mortality. MAIN OUTCOMES AND MEASURES: Infective endocarditis and in-hospital mortality after infective endocarditis. RESULTS: A total of 250 cases of infective endocarditis occurred in 20 006 patients after TAVR (incidence, 1.1% per person-year; 95% CI, 1.1%-1.4%; median age, 80 years; 64% men). Median time from TAVR to infective endocarditis was 5.3 months (interquartile range [IQR], 1.5-13.4 months). The characteristics associated with higher risk of progressing to infective endocarditis after TAVR was younger age (78.9 years vs 81.8 years; hazard ratio [HR], 0.97 per year; 95% CI, 0.94-0.99), male sex (62.0% vs 49.7%; HR, 1.69; 95% CI, 1.13-2.52), diabetes mellitus (41.7% vs 30.0%; HR, 1.52; 95% CI, 1.02-2.29), and moderate to severe aortic regurgitation (22.4% vs 14.7%; HR, 2.05; 95% CI, 1.28-3.28). Health care-associated infective endocarditis was present in 52.8% (95% CI, 46.6%-59.0%) of patients. Enterococci species and Staphylococcus aureus were the most frequently isolated microorganisms (24.6%; 95% CI, 19.1%-30.1% and 23.3%; 95% CI, 17.9%-28.7%, respectively). The in-hospital mortality rate was 36% (95% CI, 30.0%-41.9%; 90 deaths; 160 survivors), and surgery was performed in 14.8% (95% CI, 10.4%-19.2%) of patients during the infective endocarditis episode. In-hospital mortality was associated with a higher logistic EuroSCORE (23.1% vs 18.6%; odds ratio [OR], 1.03 per 1% increase; 95% CI, 1.00-1.05), heart failure (59.3% vs 23.7%; OR, 3.36; 95% CI, 1.74-6.45), and acute kidney injury (67.4% vs 31.6%; OR, 2.70; 95% CI, 1.42-5.11). The 2-year mortality rate was 66.7% (95% CI, 59.0%-74.2%; 132 deaths; 115 survivors). CONCLUSIONS AND RELEVANCE: Among patients undergoing TAVR, younger age, male sex, history of diabetes mellitus, and moderate to severe residual aortic regurgitation were significantly associated with an increased risk of infective endocarditis. Patients who developed endocarditis had high rates of in-hospital mortality and 2-year mortality.


Subject(s)
Endocarditis, Bacterial/epidemiology , Endocarditis/etiology , Hospital Mortality/trends , Transcatheter Aortic Valve Replacement/adverse effects , Age Factors , Aged , Endocarditis, Bacterial/etiology , Female , Follow-Up Studies , Heart Failure , Humans , Male , Odds Ratio , Registries , Risk Factors , Sex Factors , Staphylococcal Infections/epidemiology , Staphylococcal Infections/etiology , Staphylococcus aureus , Treatment Outcome
9.
Catheter Cardiovasc Interv ; 85(5): E153-62, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25510532

ABSTRACT

OBJECTIVE: The study sought to evaluate outcomes and predictors of mortality after transcatheter aortic valve implantation (TAVI). BACKGROUND: TAVI registries can reliably address outcomes and issues that adversely affect results in real-life. METHODS: All endpoints and complications were analyzed according to Valve Academic Research Consortium-2 criteria. RESULTS: Between January 2008 and January 2013, 418 patients underwent TAVI in 18 centers and were included in the Brazilian registry. The transfemoral approach was used in 96.2% of the procedures. The CoreValve and Sapien XT prosthesis were used in 360 (86.1%) and 58 (13.9%) cases, respectively. All-cause mortality at 30 days and 1 year were 9.1 and 21.5%. Chronic obstructive pulmonary disease (COPD) (HR: 3.50), acute kidney injury (AKI) (HR: 3.07), stroke (HR: 2.71) and moderate/severe paravalvular regurgitation (PVR) (HR: 2.76) emerged as independent predictors of overall mortality. COPD (OR: 3.00), major vascular complications (OR: 7.99) and device malpositioning (OR: 6.97) were predictors of early (≤30 days) mortality, while COPD (HR: 2.68), NYHA class III/IV (HR: 3.04), stroke (HR: 4.15), AKI (HR: 2.44) and moderate/severe PVR (HR: 3.20) impacted late (>30 days) mortality. The use of transesophageal echocardiogram (TEE) to monitor the procedure was found to be a protective factor against overall (HR: 0.57) and late (HR: 0.47) mortality. CONCLUSION: This multicenter registry reflected a real-life national TAVI experience. Comorbidities, periprocedural complications and moderate/severe PVR were associated with increased mortality and the use of TEE to monitor the procedure acted as a protective factor.


Subject(s)
Aortic Valve Stenosis/surgery , Postoperative Complications/mortality , Registries , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve Stenosis/mortality , Brazil/epidemiology , Female , Follow-Up Studies , Humans , Kaplan-Meier Estimate , Male , Retrospective Studies , Risk Factors , Survival Rate/trends , Time Factors
10.
Catheter Cardiovasc Interv ; 86(3): 501-5, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25586633

ABSTRACT

OBJECTIVE: To compare the 1-year outcomes of complete percutaneous approach versus surgical vascular approach for transfemoral transcatheter aortic valve implantation (TAVI), among "real-world" patients from the multi-center Brazilian TAVI registry. BACKGROUND: Vascular access still remains a major challenge for TAVI via transfemoral approach. Vascular access through complete percutaneous approaches or through open surgical vascular techniques seems to be acutely similar. However, the long-term outcomes of both techniques remain poorly described. METHODS: The study population comprised all patients treated via transfemoral route in the Brazilian TAVI registry, a "real-world", nation-based, multi-center study. Patients were divided according to the initial vascular access approach (percutaneous vs. surgical) and clinically followed-up for 1 year. The primary endpoint was the incidence of combined adverse events all-cause mortality, life-threatening bleeding, and/or major vascular complication at 1 year. RESULTS: A total of 402 patients from 18 centers comprised the study population (percutaneous approach in 182 patients; surgical cutdown approach 220 patients). The incidence of combined adverse events was not different in the percutaneous and the surgical groups at 30 days (17.6% vs. 16.3%; P = 0.8) and at 1 year (primary endpoint) (30.9% vs. 28.8%; P = 0.8). Also, the study groups overall were comparable regarding the incidence of each individual safety adverse events at 30 days and at 1 year. CONCLUSION: Total percutaneous techniques or surgical cutdown and closure may provide similar safety and effectiveness during the first year of follow-up in patients undergoing transfemoral TAVI.


Subject(s)
Aortic Valve Stenosis/therapy , Femoral Artery/surgery , Transcatheter Aortic Valve Replacement/methods , Aged, 80 and over , Brazil , Comorbidity , Female , Humans , Male , Registries , Risk Factors , Treatment Outcome
11.
ASAIO J ; 69(3): e121-e124, 2023 03 01.
Article in English | MEDLINE | ID: mdl-35696694

ABSTRACT

Reverse cardiac remodeling may occur in some left ventricular assist device (LVAD) recipients. Although considered the standard therapy, surgical device explantation with repeat sternotomy might be undesirable or very high risk. On the other hand, there are few data reporting minimally invasive percutaneous LVAD deactivation. We describe a case of a man with LVAD malfunction due to driveline fracture and left ventricular (LV) function recovery who had a Heart Mate II deactivated with a percutaneous technique using a left atrial appendage occluder (LAAO) positioned inside the outflow cannula. To the best of our knowledge, this the first report of LVAD deactivation with the fully recapturable LAAO device. We propose that the use of a LAA occluder to obstruct HM II outflow cannula is feasible and safe.


Subject(s)
Atrial Appendage , Heart-Assist Devices , Male , Humans , Heart-Assist Devices/adverse effects , Cannula , Ventricular Function, Left/physiology , Sternotomy
12.
JACC Cardiovasc Interv ; 16(24): 2951-2962, 2023 Dec 25.
Article in English | MEDLINE | ID: mdl-38151309

ABSTRACT

BACKGROUND: Bleeding is one of the most frequent complications in patients undergoing transcatheter aortic valve replacement (TAVR). Importantly, major bleeding is associated with poor clinical outcomes after TAVR. However, large studies on bleeding complications in the contemporary TAVR population are limited. OBJECTIVES: The aim of this study was to assess the incidence, temporal trends, clinical outcomes, and predictors of bleeding in patients undergoing transfemoral TAVR. METHODS: The CENTER2 study is a pooled patient-level database from 10 clinical studies including patients who underwent TAVR between 2007 and 2022. RESULTS: A total of 23,562 patients underwent transfemoral TAVR. The mean age was 81.5 ± 6.7 years, and 56% were women. Major bleeding within the first 30 days was observed in 1,545 patients (6.6%). Minor bleeding was reported in 1,143 patients (4.7%). Rates of major bleeding decreased from 11.5% in 2007-2010 to 5.5% in 2019-2022 (Ptrend < 0.001). Dual antiplatelet therapy was associated with higher major bleeding rates compared with single antiplatelet therapy (12.2% vs 9.1%; OR: 1.40; 95% CI: 1.13-1.72; P = 0.002). Patients with major bleeding had increased mortality risk during the first 30 days (14.1% vs 4.3%; OR: 3.66; 95% CI: 3.11-4.31; P < 0.001) and during 1-year follow-up (27.8% vs 14.5%; HR: 1.50; 95% CI: 1.41-1.59; P < 0.001). Minor bleeding did not affect 1-year mortality risk (16.7% vs 14.5%; HR: 1.11; 95% CI: 0.93-1.32; P = 0.27). Predictors of major bleeding were female sex and peripheral vascular disease. CONCLUSIONS: Bleeding complications remain frequent and important in patients undergoing transfemoral TAVR. Increased mortality risk in major bleeding persists after the initial 30 days. (Cerebrovascular Events in Patients Undergoing Transcatheter Aortic Valve Implantation With Balloon-Expandable Valves Versus Self-Expandable Valves [CENTER]; NCT03588247).


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Male , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Incidence , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Hemorrhage/epidemiology , Hemorrhage/etiology , Risk Factors
13.
Front Cardiovasc Med ; 10: 1161779, 2023.
Article in English | MEDLINE | ID: mdl-37529710

ABSTRACT

Paravalvular leak (PVL) is a shortcoming that can erode the clinical benefits of transcatheter valve replacement (TAVR) and therefore a readily applicable method (aortography) to quantitate PVL objectively and accurately in the interventional suite is appealing to all operators. The ratio between the areas of the time-density curves in the aorta and left ventricular outflow tract (LVOT-AR) defines the regurgitation fraction (RF). This technique has been validated in a mock circulation; a single injection in diastole was further tested in porcine and ovine models. In the clinical setting, LVOT-AR was compared with trans-thoracic and trans-oesophageal echocardiography and cardiac magnetic resonance imaging. LVOT-AR > 17% discriminates mild from moderate aortic regurgitation on echocardiography and confers a poor prognosis in multiple registries, and justifies balloon post-dilatation. The LVOT-AR differentiates the individual performances of many old and novel devices and is being used in ongoing randomized trials and registries.

14.
Am J Cardiol ; 172: 81-89, 2022 06 01.
Article in English | MEDLINE | ID: mdl-35351288

ABSTRACT

The use of valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) is increasing, but studies evaluating clinical outcomes in these patients are scarce. Also, there are limited data to guide the choice of valve type in ViV-TAVI. Therefore, this CENTER-study evaluated clinical outcomes in patients with ViV-TAVI compared to patients with native valve TAVI (NV-TAVI). In addition, we compared outcomes in patients with ViV-TAVI treated with self-expandable versus balloon-expandable valves. A total of 256 patients with ViV-TAVI and 11333 patients with NV-TAVI were matched 1:2 using propensity score matching, resulting in 256 patients with ViV-TAVI and 512 patients with NV-TAVI. Mean age was 81±7 years, 58% were female, and the Society of Thoracic Surgeons Predicted Risk of Mortality was 6.3% (4.0% to 12.8%). Mortality rates were comparable between ViV-TAVI and NV-TAVI patients at 30 days (4.1% vs 5.9%, p = 0.30) and 1 year (14.2% vs 17.3%, p = 0.34). Stroke rates were also similar at 30 days (2.8% vs 1.8%, p = 0.38) and 1 year (4.9% vs 4.3%, p = 0.74). Permanent pacemakers were less frequently implanted in patients with ViV-TAVI (8.8% vs 15.0%, relative risk 0.59, 95% confidence interval [CI] 0.37 to 0.92, p = 0.02). Patients with ViV-TAVI were treated with self-expandable valves (n = 162) and balloon-expandable valves (n = 94). Thirty-day major bleeding was less frequent in patients with self-expandable valves (3% vs 13%, odds ratio 5.12, 95% CI 1.42 to 18.52, p = 0.01). Thirty-day mortality was numerically lower in patients with self-expandable valves (3% vs 7%, odds ratio 3.35, 95% CI 0.77 to 14.51, p = 0.11). In conclusion, ViV-TAVI seems a safe and effective treatment for failing bioprosthetic valves with low mortality and stroke rates comparable to NV-TAVI for both valve types.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Bioprosthesis/adverse effects , Female , Heart Valve Prosthesis/adverse effects , Humans , Male , Prosthesis Design , Stroke/epidemiology , Stroke/etiology , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
15.
J Cardiol Cases ; 26(3): 181-185, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36091613

ABSTRACT

Patients presenting with aortic stenosis and atrial fibrillation (AF) undergoing transcatheter aortic valve replacement (TAVR) are commonly at increased risk for stroke and bleeding complications. Concomitant left atrial appendage occlusion (LAAO) after TAVR may be an alternative to oral anticoagulation (OAC).Between 2018 and 2022, 7 consecutive patients who were ineligible for OAC underwent simultaneous TAVR and LAAO. The mean age was 84.9 ±â€¯4.9 years. The mean CHA2DS2-VASc, HAS-BLED, and STS predicted risk of mortality scores were 5.9 ±â€¯0.7, 3.9 ±â€¯1.1, and 8.8 ±â€¯3.4%, respectively. The median follow-up time was 23 (1 to 27) months. All procedures achieved technical success and no adverse events were observed during follow-up. This case series shows that concomitant TAVR and LAAO is feasible and safe among patients with severe aortic stenosis and AF who are deemed ineligible for OAC. Learning objectives: Atrial fibrillation is the most common arrhythmia in the transcatheter aortic valve replacement (TAVR) population. In those who experience major or life-threatening bleeding, mortality is doubled. We report a case series of 7 concomitant left atrial appendage occlusions (LAAO) after TAVR in patients ineligible for oral anticoagulation. All procedures achieved technical success and no adverse events were observed. The simultaneous approach with TAVR and LAAO was feasible and safe in this case series.

16.
Cardiorenal Med ; 11(4): 166-173, 2021.
Article in English | MEDLINE | ID: mdl-34261063

ABSTRACT

BACKGROUND: Acute kidney injury (AKI) has shown to adversely affect outcomes in patients undergoing transcutaneous aortic valve replacement (TAVR), and its correct risk estimation may interfere in procedural planning and strategies. The aim of the study was to test and compare 6 scores in predicting AKI after TAVR. METHODS: We tested 6 scores (the contrast material limit score, volume-to-creatinine clearance ratio, ACEF, CR4EATME3AD3, Mehran model A, and Mehran model B) in a total of 559 consecutive patients included in the Brazilian TAVR registry. RESULTS: All scores had a poor accuracy and calibration to predict the occurrence of AKI grade 1 or 2. All scores improved the accuracy of AKI risk prediction when stratified for AKI grade 2/3 and AKI grade 3 for all scores. The CR4EATME3AD3 was the best predictor of AKI stage 2/3 (AUC: 0.62; OR: 1.12; 95% CI 1.01-1.26; p = 0.04) and AKI stage 3 (AUC: 0.64; OR: 1.16; 95% CI 1.02-1.32; p = 0.02). Mehran models A and B were both good models for AKI stage 3 (AUC: 0.63; OR: 1.10; 95% CI 1.01-1.22; p = 0.05; and AUC: 0.62; OR: 1.10; 95% CI 1.00-1.21; p = 0.05, respectively). CONCLUSIONS: None of the current models demonstrated validity in detecting AKI when its lower grades were evaluated. CR4EATME3AD3 was the best score in predicting moderate to severe AKI after TAVR. These findings suggest that contrast-induced AKI may not be the only factor related to kidney injury after TAVR.


Subject(s)
Acute Kidney Injury , Aortic Valve Stenosis , Heart Valve Prosthesis , Acute Kidney Injury/chemically induced , Acute Kidney Injury/diagnosis , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Humans , Risk Factors
17.
Am J Cardiol ; 152: 43-48, 2021 08 01.
Article in English | MEDLINE | ID: mdl-34175106

ABSTRACT

The patient reported angina measurement with the Seattle Angina Questionnaire (SAQ) has shown to have prognostic implications and became an endpoint in clinical trials. Our objective was to study physician-reported and SAQ severity with the total coronary atherosclerotic burden as assessed by 4 angiographic scores. We prospectively analyzed data of consecutive patients scheduled for coronary angiography or percutaneous coronary intervention. The Canadian Cardiovascular Society (CCS) angina categories was used as physician-reported angina. SAQ domains were categorized as severe (0 to 24), moderate 25 to 75 and mild angina (>75). All angina assessments were done before coronary angiography. Gensini, Syntax, Friesinger, and Sullivan angiographic scores were used for total atherosclerotic burden quantification: 261 patients were included in the present analysis. The median age was 66.0 (59.0 to 71.8) years, 53.6% were male and 43.7% had diabetes. The median SYNTAX score was 6.0 (0 to 18.0). The worse the symptoms of CCS categories, the more severe was the atherosclerotic burden in all angiographic scores: SYNTAX (p = 0.01); Gensini (p <0.01); Friesinger (p = 0.02) and Sullivan (p = 0.03). Conversely, SAQ domains were not able to discriminate the severity of CAD in any of the scores. The only exception was the severe SAQ quality of life that had worse Gensini score than the mild SAQ quality of life (p = 0.04). In conclusion, CCS angina categories are related to the total atherosclerotic burden in coronary angiography, by all angiographic scores. SAQ domains should be used as a measure of patient functionality and quality of life but not as a measure of CAD severity.


Subject(s)
Angina Pectoris/physiopathology , Atherosclerosis/physiopathology , Coronary Angiography , Coronary Artery Disease/physiopathology , Percutaneous Coronary Intervention , Aged , Angina Pectoris/diagnostic imaging , Atherosclerosis/diagnostic imaging , Atherosclerosis/surgery , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Female , Humans , Male , Middle Aged , Patient Reported Outcome Measures , Prognosis , Prospective Studies , Severity of Illness Index , Surveys and Questionnaires
18.
PLoS One ; 16(5): e0251066, 2021.
Article in English | MEDLINE | ID: mdl-33984005

ABSTRACT

BACKGROUND: Chronic kidney disease is commonly found in patients with aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) and has marked impact in their prognosis. It has been shown however that TAVR may improve renal function by alleviating the hemodynamic barrier imposed by AS. Nevertheless, the predictors of and clinical consequences of renal function improvement are not well established. Our aim was to assess the predictors of improvement of renal function after TAVR. METHODS: The present work is an analysis of the Brazilian Registry of TAVR, a national non-randomized prospective study with 22 Brazilian centers. Patients with baseline renal dysfunction (estimated glomerular filtration rate [eGFR] < 60mL/min/1.73m2) were stratified according to renal function after TAVR: increase >10% in eGFR were classified as TAVR induced renal function improvement (TIRFI); decrease > 10% in eGFR were classified as acute kidney injury (AKI) and stable renal function (neither criteria). RESULTS: A total of 819 consecutive patients with symptomatic severe AS were included. Of these, baseline renal dysfunction (estimated glomerular filtration rate [eGFR] < 60mL/min/1.73m2) was present in 577 (70%) patients. Considering variance in renal function between baseline and at discharge after TAVR procedure, TIRFI was seen in 197 (34.1%) patients, AKI in 203 (35.2%), and stable renal function in 177 (30.7%). The independent predictors of TIRFI were: absence of coronary artery disease (OR: 0.69; 95% CI 0.48-0.98; P = 0.039) and lower baseline eGFR (OR: 0.98; 95% CI 0.97-1.00; P = 0.039). There was no significant difference in 30-day and 1-year all-cause mortality between patients with stable renal function or TIRFI. Nonetheless, individuals that had AKI after TAVR presented higher mortality compared with TIRFI and stable renal function groups (29.3% vs. 15.4% vs. 9.5%, respectively; p < 0.001). CONCLUSIONS: TIRFI was frequently found among baseline impaired renal function individuals but was not associated with improved 1-year outcomes.


Subject(s)
Kidney/physiology , Renal Insufficiency, Chronic/physiopathology , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Female , Glomerular Filtration Rate/physiology , Heart Valve Prosthesis Implantation/methods , Hemodynamics/physiology , Humans , Kidney Function Tests/methods , Logistic Models , Male , Odds Ratio , Prognosis , Prospective Studies , Renal Insufficiency, Chronic/complications , Renal Insufficiency, Chronic/surgery , Risk Assessment , Risk Factors , Severity of Illness Index , Treatment Outcome
19.
J Clin Med ; 10(17)2021 Sep 04.
Article in English | MEDLINE | ID: mdl-34501454

ABSTRACT

BACKGROUND: Both balloon-expandable (BE) and self-expandable (SE) valves for transcatheter aortic valve implantation (TAVI) are broadly used in clinical practice. However, adequately powered randomized controlled trials comparing these two valve designs are lacking. METHODS: The CENTER-study included 12,381 patients undergoing transfemoral TAVI. Patients undergoing TAVI with a BE-valve (n = 4096) were compared to patients undergoing TAVI with an SE-valve (n = 4096) after propensity score matching. Clinical outcomes including one-year mortality and stroke rates were assessed. RESULTS: In the matched population of n = 5410 patients, the mean age was 81 ± 3 years, 60% was female, and the STS-PROM predicted 30-day mortality was 6.2% (IQR 4.0-12.4). One-year mortality was not different between patients treated with BE- or SE-valves (BE: 16.4% vs. SE: 17.0%, Relative Risk 1.04, 95%CI 0.02-1.21, p = 0.57). One-year stroke rates were also comparable (BE: 4.9% vs. SE: 5.3%, RR 1.09, 95%CI 0.86-1.37, p = 0.48). CONCLUSION: This study suggests that one-year mortality and stroke rates were comparable in patients with severe aortic valve stenosis undergoing TAVI with either BE or SE-valves.

20.
JACC Cardiovasc Interv ; 13(11): 1303-1311, 2020 06 08.
Article in English | MEDLINE | ID: mdl-32499020

ABSTRACT

OBJECTIVES: The aim of this study was to assess acute regurgitation following transcatheter aortic valve replacement, comparing different implanted transcatheter heart valves. BACKGROUND: Regurgitation following transcatheter aortic valve replacement influences all-cause mortality. Thus far, no quantitative comparison of regurgitation among multiple commercially available transcatheter heart valves has been performed. METHODS: Aortograms from a multicenter cohort of consecutive 3,976 transcatheter aortic valve replacements were evaluated in this pooled analysis. A total of 2,258 (58.3%) were considered analyzable by an independent academic core laboratory using video densitometry. Results of quantitative regurgitation are shown as percentages. The valves evaluated were the ACURATE (n = 115), Centera (n = 11), CoreValve (n = 532), Direct Flow Medical (n = 21), Evolut PRO (n = 95), Evolut R (n = 295), Inovare (n = 4), Lotus (n = 546), Lotus Edge (n = 3), SAPIEN XT (n = 239), and SAPIEN 3 (n = 397). For the main analysis, only valves with more than 50 procedures (7 types) were used. RESULTS: The Lotus valve had the lowest mean regurgitation (3.5 ± 4.4%), followed by Evolut PRO (7.4 ± 6.5%), SAPIEN 3 (7.6 ± 7.1%), Evolut R (7.9 ± 7.4%), SAPIEN XT (8.8 ± 7.5%), ACURATE (9.6 ± 9.2%) and CoreValve (13.7 ± 10.7%) (analysis of variance p < 0.001). The only valves that statistically differed from all their counterparts were Lotus (as the lowest regurgitation) and CoreValve (the highest). The proportion of patients presenting with moderate or severe regurgitation followed the same ranking order: Lotus (2.2%), Evolut PRO (5.3%), SAPIEN 3 (8.3%), Evolut R (8.8%), SAPIEN XT (10.9%), ACURATE (11.3%), and CoreValve (30.1%) (chi-square p < 0.001). CONCLUSIONS: In this pooled analysis stemming from daily clinical practice, the Lotus valve was shown to have the best immediate sealing. This analysis reflects the objective evaluation of regurgitation by an academic core laboratory (nonsponsored) in a real-world cohort of patients using a quantitative technique.


Subject(s)
Aortic Valve Insufficiency/etiology , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Aortic Valve Insufficiency/diagnostic imaging , Feasibility Studies , Humans , Retrospective Studies , Risk Factors , Severity of Illness Index , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL