1.
Haemophilia ; 30(2): 437-448, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38314918

ABSTRACT

INTRODUCTION: Considering the advances in haemophilia management and treatment observed in the last decades, a new set of value-based outcome indicators is needed to assess the quality of care and the impact of these medical innovations. AIM: The Value-Based Healthcare in Haemophilia project aimed to define a set of clinical outcome indicators (COIs) and patient-reported outcome indicators (PROIs) to assess quality of care in haemophilia in high-income countries with a value-based approach to inform and guide the decision-making process. METHODS: A Value-based healthcare approach based on the available literature, current guidelines and the involvement of a multidisciplinary group of experts was applied to generate a set of indicators to assess the quality of care of haemophilia. RESULTS: A final list of three COIs and five PROIs was created and validated. The identified COIs focus on two domains: musculoskeletal health and function, and safety. The identified PROIs cover five domains: bleeding frequency, pain, mobility and physical activities, Health-Related Quality of Life and satisfaction. Finally, two composite outcomes, one based on COIs, and one based on PROIs, were proposed as synthetic outcome indicators of quality of care. CONCLUSION: The presented standard set of health outcome indicators provides the basis for harmonised longitudinal and cross-sectional monitoring and comparison. The implementation of this value-based approach would enable a more robust assessment of quality of care in haemophilia, within a framework of continuous treatment improvements with potential added value for patients. Moreover, proposed COIs and PROIs should be reviewed and updated routinely.


Subject(s)
Hemophilia A , Humans , Hemophilia A/drug therapy , Quality of Life , Cross-Sectional Studies , Value-Based Health Care , Outcome Assessment, Health Care
2.
Eur J Orthop Surg Traumatol ; 34(4): 2121-2128, 2024 May.
Article in English | MEDLINE | ID: mdl-38555541

ABSTRACT

BACKGROUND AND PURPOSE: The aim of this study was to evaluate whether this system is associated with a reduced rate of failure and complications in patients treated for proximal femoral fractures with intramedullary nailing. MATERIALS AND METHODS: 742 Patients with AO-OTA 31-A intertrochanteric fractures were enrolled at a single Institution. Functional evaluation was assessed through the Functional Independence Measure (FIM™) instrument and Parker's New Mobility Score (NMS). Radiological follow-up included the degree of the reduction according to the Baumgartner criteria, the Tip-Apex Distance, and the shortening of the telescoping screws and its lateral protrusion. RESULTS: Pre-operative mean FIM™ and NMS were 4.3 (range 1-9) and 98.7 (range 22-126), respectively. At the 12-month follow-up the average FIM™ and NMS were 95.3 (range 22-126) and 3.7 (range 1-9), respectively. Mean shortening of the lag screws was 4.3 mm (range 1-8) and mean lateral protrusion was 1.7 mm (range 0-3). 3 Cases (0.70%) of non-consolidation requiring reoperation were recorded. 1 Case (0.24%) of these cases was also characterized by nail breakage. No case of cut-out has been reported at our follow-up. CONCLUSIONS: This dual telescoping nail system is effective and safe. The sliding of the telescoping screws within the barrel is able to decrease strain from the femoral head during weight bearing reducing the risk of cut-out.


Subject(s)
Bone Nails , Bone Screws , Fracture Fixation, Intramedullary , Hip Fractures , Humans , Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/adverse effects , Male , Female , Aged , Hip Fractures/surgery , Hip Fractures/diagnostic imaging , Retrospective Studies , Aged, 80 and over , Middle Aged , Treatment Outcome , Radiography , Adult , Postoperative Complications/prevention & control , Postoperative Complications/etiology
3.
Eur J Orthop Surg Traumatol ; 34(1): 479-487, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37624410

ABSTRACT

PURPOSE: The aim of this study was to evaluate the relationship between the Löwenstein Lateral view and the True Lateral view for the positioning of the cephalic hip screw, through a cadaveric study. MATERIALS AND METHODS: We placed two Kirschner wires in eight femur specimens using an Antero-Posterior view, Löwenstein Lateral view and True Lateral view. The distances between the Kirschner wires and the anterior, posterior, superior and inferior cortex were measured in all projections. The head of the femur was then sectioned, and the same macroscopic distances were measured. Finally, we could calculate the accuracy of the two radiographic lateral projections. RESULTS: When the Kirschner wire was placed in the center of the head using the Antero-Posterior and the True Lateral view, the accuracy of Antero-Posterior view was 0.9705 while the accuracy of True Lateral view and Löwenstein Lateral view was 1.1479 and 1.1584, respectively. When the Kirschner wire was placed superior on the Antero-Posterior and centrally on the True Lateral view, the accuracy of Antero-Posterior view was 0.9930 while the accuracy of True Lateral view and Löwenstein Lateral view was 1.1159 and 0.7224, respectively. CONCLUSION: When the Kirschner wire was positioned proximal in Antero-Posterior view and central in True Lateral view, only the True Lateral view showed high accuracy.


Subject(s)
Femoral Fractures , Humans , Femoral Fractures/surgery , Bone Screws , Femur/surgery , Lower Extremity , Cadaver , Fracture Fixation, Internal
4.
Haemophilia ; 29(2): 435-444, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36469855

ABSTRACT

INTRODUCTION: Current treatment for haemophilia A involves factor VIII replacement or non-replacement (emicizumab) therapies, neither of which permanently normalise factor VIII levels. Gene therapy using adeno-associated viral (AAV) vectors is an emerging long-term treatment strategy for people with severe haemophilia A (PwSHA) that is likely to be available for clinical use in the near future. AIM: This article proposes practical guidelines for the assessment, treatment, and follow-up of potential PwSHA candidates for AAV-based gene therapy. METHOD: Using the Delphi method, a working group of Italian stakeholders with expertise in and knowledge of the care of adults with haemophilia A analysed literature for AAV-based gene therapy and drafted a list of statements that were circulated to a panel of Italian peers. During two rounds of voting, panel members voted on their agreement with each statement to reach a consensus. RESULTS: The Delphi process yielded 40 statements regarding haemophilia A gene therapy, across five topics: (1) organisational model; (2) multidisciplinary team; (3) patient engagement; (4) laboratory surveillance; and (5) patient follow-up and gene therapy outcomes. The consensus was reached for all 40 statements, with the second round of voting needed for five statements. CONCLUSION: Use of the hub-and-spoke organisational model and multidisciplinary teams are expected to optimise patient selection for gene therapy, as well as the management of dosing and patient follow-up, patient engagement, laboratory surveillance, and patient expectations regarding outcomes. This approach should allow the benefits of AAV-based gene therapy for haemophilia A to be maximised.


Subject(s)
Hemophilia A , Humans , Hemophilia A/genetics , Hemophilia A/therapy , Factor VIII , Delphi Technique , Italy , Genetic Therapy
5.
J Arthroplasty ; 38(9): 1773-1778, 2023 09.
Article in English | MEDLINE | ID: mdl-36822447

ABSTRACT

BACKGROUND: Hip hemiarthroplasty dislocation is a devastating complication. Among other preoperative risk factors, acetabular morphology has been rarely studied. The purpose of the study was to evaluate the influence of preoperative native acetabular morphology on hemiarthroplasty dislocation. METHODS: We retrospectively reviewed 867 patients who underwent hip hemiarthroplasty for femoral neck fracture between January 1, 2014 and January 1, 2019. The 380 included patients were treated with an anterior-based muscle-sparing approach. The central-edge angle (CEA) and acetabular depth-to-width ratio (ADWR) of the fractured hip were measured preoperatively on the anteroposterior pelvic view. Receiver operating characteristic curves were performed to analyze the optimal cutoff for CEA and ADWR. Hemiarthroplasty dislocation occurred in 18 patients (4.7%), and the remaining 362 patients were used as the control group. RESULTS: No significant differences in terms of sex, age, dementia, neuromuscular disease, and body mass index were found between the 2 groups. The 18 patients who had a hip dislocation had significantly smaller mean CEA than the control group (P = .0001) (mean 36.1 ± 7.5° and 43.2 ± 5.6°, respectively) as well as ADWR (mean 34 ± 6 versus 37 ± 4, respectively) (P = .001). Using the receiver operating characteristic analysis, we report significant cutoffs of 38.5° for CEA (P = .0001) and 34.5 for the ADWR (P = .017). CONCLUSION: Higher rates of hemiarthroplasty dislocation were observed in patients who had a preoperative CEA of less than 38.5° and an ADWR of less than 34.5. Patients who have preoperative acetabular morphological risk factors for dislocation might be better candidates for a total hip arthroplasty.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Neck Fractures , Hemiarthroplasty , Hip Dislocation , Joint Dislocations , Humans , Aged , Retrospective Studies , Hemiarthroplasty/adverse effects , Acetabulum/surgery , Joint Dislocations/epidemiology , Joint Dislocations/etiology , Joint Dislocations/surgery , Femoral Neck Fractures/surgery , Femoral Neck Fractures/complications , Hip Dislocation/epidemiology , Hip Dislocation/etiology , Hip Dislocation/surgery , Arthroplasty, Replacement, Hip/adverse effects
6.
Br J Haematol ; 196(4): 871-883, 2022 02.
Article in English | MEDLINE | ID: mdl-34923621

ABSTRACT

Although synovitis is recognized as a marker of joint disease activity, its periodic assessment is not included in routine clinical surveillance of patients with haemophilia (PwH). In order to evaluate the current knowledge and to identify controversial issues, a preliminary literature search by the Musculoskeletal Committee of the Italian Association of Haemophilia Centres (AICE) has been conducted. Statements have been established and sent to the Italian AICE members to collect their level of agreement or disagreement by a Delphi process. Thirty-seven consensus recommendations have been drafted. We found a general agreement on the indication to consider the presence of synovitis as a marker of joint disease activity in PwH. Accordingly, there was agreement on the indication to search for synovitis both in patients reporting joint pain and in asymptomatic ones, recognizing ultrasound as the most practical imaging technique to perform periodic joint screening. Interestingly, after detection of synovitis, there was agreement on the indication to modify the therapeutic approach, suggesting prophylaxis in patients treated on demand and tailoring treatment in patients already under prophylaxis. Whereas the need of an early consultation with a physiotherapist is recommended for PwH affected by chronic synovitis, the exact timing for an orthopaedic surgeon consultation is currently unknown.


Subject(s)
Hemophilia A/complications , Synovitis/diagnosis , Synovitis/therapy , Chronic Disease , Consensus , Hemophilia A/pathology , Humans , Italy
7.
Arch Orthop Trauma Surg ; 142(11): 3523-3531, 2022 Nov.
Article in English | MEDLINE | ID: mdl-34782910

ABSTRACT

AIMS: In case of severe bone loss, acetabular revision can be challenged using extra porous pure trabecular titanium (TT) revision cups designed to ensure enhanced iliac and ischiatic purchase. Aim of the study is to report on the clinical and radiological results of a TT acetabular component, evaluating functional outcome, restoration of the hip center of rotation and osteointegration. METHODS: 85 patients, who underwent acetabular revision with a TT revision cup system between October 2009 and December 2018, were included in a retrospective study. Clinical outcome were assessed with Harris Hip Score (HHS). The hip rotation center was measured using the Pierchon method on the AP pelvis film. Loosening of the cup was determined according to the Kosashvili modification of Gill's criteria. Kaplan- Meier survivorship curve was performed. Results The mean follow-up was 6.12 years. The average HHS improved from 54.7 points to 89.7 points (p < 0.05). Two acetabular components (2.3%) were re-revised after a mean of 5.6 years, for aseptic loosening and for infection, with a progressive radiolucency and a > 5 mm vertical migration, respectively. The radiographic evaluation of the position of the hip rotation center revealed a statistically significant difference (p < 0.05) between the pre- and post-operative values. The hip rotation center was correctly restored within 5% of the reference Pierchon values in a percentage of 85.4% relative to horizontal parameters and within 8% in a percentage of 66.7% relative to vertical parameters. 5-year and 10-year survivorships were, respectively, 100% and 88%. CONCLUSIONS: In case of severe bone loss, TT revision cup system allows for good restoration of center of rotation and osteointegration showing good 10-year survival rate.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Follow-Up Studies , Humans , Prosthesis Failure , Reoperation , Retrospective Studies , Rotation , Survivorship , Titanium
8.
Haemophilia ; 27(1): e93-e101, 2021 Jan.
Article in English | MEDLINE | ID: mdl-32997896

ABSTRACT

INTRODUCTION: The association between haemophilia and the so-called 'inhibitors', alloantibodies against the infused factor able to neutralize its clotting activity, is a very rare condition. Those sporadic patients suffer of an even more severe arthropathy and performing primary or revision arthroplasty become truly challenging. Literature about this topic is scarce, consisting in small case series, high rates of complications and mid-term follow-ups. AIM: The purpose of this study is the assessment of the long-term outcomes of primary and revision arthroplasty performed in a population of patients with inhibitors, the more consistent to date reported at a single haemophilia centre. METHODS: We reviewed the records of 18 patients with inhibitors (26 procedures) between 1999 and 2017, divided in two groups. Group A [primary total Knee-Hip arthroplasty (TKA-THA)]: 13 patients underwent 19TKA and 2THA; and B (revision): 5 subjects underwent 3rTKA and 2rTHA. All patients received the same haematological prophylaxis (rFVIIa). Haemophilic Joint Health score and VAS, and X-rays were recorded pre- and postoperatively. The survival rate of all primary implants was assessed. RESULTS: The median follow-up was 12.2 years (3-21) for group A, 8.6 years (4-12) for B. Few complications have been reported; the overall survival rate was 94.7% at 15 years. All patients reported satisfaction, pain reduction and improved functional ability. CONCLUSION: Primary and revision TKA/THA in haemophilic subjects and inhibitors may be nowadays considered safe and effective if performed in dedicated multidisciplinary centres. The use of continuous infusion of rFVIIa showed an adequate haemostatic effect and low rate of complications. As expected, revisions are more prone to complications compared to primary arthroplasty.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Hemophilia A , Joint Diseases , Arthroplasty, Replacement, Knee/adverse effects , Hemophilia A/complications , Hemophilia A/drug therapy , Humans , Joint Diseases/drug therapy , Joint Diseases/etiology , Joint Diseases/surgery , Knee Joint/surgery , Retrospective Studies , Treatment Outcome
9.
J Arthroplasty ; 35(6S): S294-S298, 2020 06.
Article in English | MEDLINE | ID: mdl-32197964

ABSTRACT

BACKGROUND: Modular dual-mobility (MDM) total hip arthroplasty (THA) is designed with a cobalt-chromium liner inserted into a titanium acetabular component. The purpose of this study is to investigate the potential risks for fretting corrosion at this junction, by measuring serum metal ions, after MDM acetabular revision. METHODS: Thirty-seven patients with well-functioning revision THAs participated in a cross-sectional study at mean 5.1 (2-10) years after surgery. All received a trabecular titanium MDM acetabular component. The serum levels of cobalt and chromium were measured using mass spectrometry. RESULTS: The mean values of chromium and cobalt were 2.08 µg/L (95% confidence interval 0.9-3.2, range 0.02-11.8) and 1.99 µg/L (95% confidence interval 0.81-3.17, range 0.07-16.05), respectively. Eleven patients (29, 7%) had ion levels above the normal range, with 6 (16.2%) above 5 µg/L and 5 (13.5%) between 1 and 5 µg/L. A significant correlation was found between an elevated serum metal ion level and University of California Los Angeles score (P = .016). CONCLUSION: We conclude that serum metal level elevation may occur secondary to metal debris resulting from corrosion of the index MDM THA. This potential risk should be included in the decision-making process when dealing with revision arthroplasty in young and active patients.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Arthroplasty, Replacement, Hip/adverse effects , Chromium , Cobalt , Cross-Sectional Studies , Hip Prosthesis/adverse effects , Humans , Ions , Los Angeles , Prosthesis Design , Prosthesis Failure
10.
Epidemiol Prev ; 44(2-3): 154-161, 2020.
Article in Italian | MEDLINE | ID: mdl-32631015

ABSTRACT

OBJECTIVES: to observe the prevalence of vertebral deformities in an adolescent population in the 178 schools of the District of Florence (Tuscany Region, Central Italy), correlating these results with clinical aspects as ligamentous laxity and verifying if these data are in agreement with what emerged in literature in studies of the same type. DESIGN: prevalence study. SETTING AND PARTICIPANTS: report of the results of a school screening for vertebral deformities in an adolescent population of 11,820 students of the Schools of District of Florence held between November 2010 and June 2013. MAIN OUTCOMES MEASURES: asymmetry of waist triangle; trunk imbalance using plumb-line from C7; leg length discrepancies; presence of gibbus and measurement of Angle of Trunk Rotation using Bunnell scoliometer; measure of thoracic kyphosis (a value of kyphosis> 50° was considered to be at high risk of hyperkyphosis making it necessary to request an X-ray); ligamuentuos laxity using Beighton Score. RESULTS: 11,820 students were screened; 85.95% of them had no significant spinal deformities; 14,05% of the students showed significant clinical signs of scoliosis; 28.46% of the students had a thoracic hyperkyphosis (>40°), 1.55% of those presented a non-reducible thoracic hyperkyphosis. Results show a statistically significant correlation between the severity of the deformities and the score of the Beighton Score. CONCLUSIONS: the results confirm the association between vertebral deformities and ligament laxity. The prevalence of vertebral deformities in the school age population of the Municipality of Florence is 14.05%, in accordance with what emerged in the literature from similar studies.


Subject(s)
Scoliosis/epidemiology , Adolescent , Cross-Sectional Studies , Female , Humans , Italy/epidemiology , Male , Mass Screening , Prevalence , Research , Students
11.
J Orthop Traumatol ; 21(1): 5, 2020 Mar 28.
Article in English | MEDLINE | ID: mdl-32222861

ABSTRACT

BACKGROUND: Partial lesions of the anterior cruciate ligament (ACL) are more common than is generally thought, accounting for about 10-12% of ACL injuries. Selective reconstruction may be considered as an option in isolated bundle rupture. The purpose of this study is to evaluate both subjective and objective clinical results, as well as functional recovery time, after selective arthroscopic single-bundle reconstruction in a consecutive series of patients affected by partial ACL rupture. MATERIALS AND METHODS: Thirty-six patients undergoing selective reconstruction of a single ACL bundle were retrospectively evaluated from a series of 354 ACL reconstructions performed over a 3-year period. Although the suspicion of partial lesions was present at clinical and magnetic resonance imaging (MRI) evaluation, final diagnosis was obtained during arthroscopy. All patients were operated using the same technique and type of fixation, and undergoing the same functional recovery protocol. RESULTS: Mean follow-up was 64 months (48-84 months). All patients but one achieved good functional recovery and returned to their sports within a mean period of 6.1 months. A single patient complained of postoperative instability 1 year after the index operation and needed further surgery. No complications were recorded. CONCLUSIONS: Selective reconstruction of partial ACL injury is a method to bear in mind because it offers quick functional recovery. Specific technical and diagnostic steps should be performed and discussed with patients preoperatively. LEVEL OF EVIDENCE: Level 4, retrospective study.


Subject(s)
Anterior Cruciate Ligament Injuries/surgery , Anterior Cruciate Ligament Reconstruction/methods , Anterior Cruciate Ligament/surgery , Arthroscopy/methods , Adolescent , Adult , Anterior Cruciate Ligament/diagnostic imaging , Anterior Cruciate Ligament/physiopathology , Anterior Cruciate Ligament Injuries/diagnosis , Anterior Cruciate Ligament Injuries/physiopathology , Female , Humans , Magnetic Resonance Imaging , Male , Recovery of Function , Retrospective Studies , Rupture , Young Adult
13.
Int Orthop ; 43(1): 47-53, 2019 01.
Article in English | MEDLINE | ID: mdl-30284607

ABSTRACT

PURPOSE: The purpose of this study was to evaluate safety, efficacy, and learning curves of anterior-based muscle-sparing total hip arthroplasty (ABMS-THA) in the supine position. Furthermore, early functional outcome was evaluated and compared to direct anterior approach (DAA) by measuring surface electromyography (sEMG). METHODS: We present a prospective cohort study of 343 hips. The safety and learning curve were assessed by recording operative time and peri-operative adverse events. For assessment of efficacy, functional and radiological outcomes were evaluated. A selected group of 32 patients have been studied by sEMG and compared to a matched group of 32 patients who received a THA using DAA approach. RESULTS: There was one dislocation (0.3%); two (0.6%) patients had an intra-operative fractures of the greater trochanter; two patients (0.6%) experienced a self-limited femoral nerve palsy. Physical therapy milestones for hospital discharge were reached on an average of 1.7 days. sEMG showed that ABMS and DAA have a similar muscle recruitment pattern and functional recovery after THA. One patient was revised for infection, 16 were lost, and 326 hips were available with a median follow-up of 42 months (range 24-60). The mean Harris Hip Score (HSS) increased from 44.3 to 91.9. Ninety-six percent of the hips had a leg length discrepancy (LLD) < 5 mm. There were no radiological signs of mechanical loosening or osteolysis. CONCLUSIONS: The ABMS approach in the supine position is clinically effective and safe; special advantages include a very low dislocation rate and a great control of LLD.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Hip Joint/surgery , Joint Diseases/surgery , Learning Curve , Muscle, Skeletal/surgery , Adult , Aged , Aged, 80 and over , Electromyography , Female , Hip/surgery , Humans , Male , Middle Aged , Muscle, Skeletal/physiopathology , Prospective Studies , Recovery of Function
14.
Knee Surg Sports Traumatol Arthrosc ; 26(2): 468-477, 2018 Feb.
Article in English | MEDLINE | ID: mdl-28631143

ABSTRACT

PURPOSE: To evaluate the feedback from post-operative three-dimensional computed tomography (3D-CT) on femoral tunnel placement in the learning process, to obtain an anatomic anterior cruciate ligament (ACL) reconstruction. METHODS: A series of 60 consecutive patients undergoing primary ACL reconstruction using autologous hamstrings single-bundle outside-in technique were prospectively included in the study. ACL reconstructions were performed by the same trainee-surgeon during his learning phase of anatomic ACL femoral tunnel placement. A CT scan with dedicated tunnel study was performed in all patients within 48 h after surgery. The data obtained from the CT scan were processed into a three-dimensional surface model, and a true medial view of the lateral femoral condyle was used for the femoral tunnel placement analysis. Two independent examiners analysed the tunnel placements. The centre of femoral tunnel was measured using a quadrant method as described by Bernard and Hertel. The coordinates measured were compared with anatomic coordinates values described in the literature [deep-to-shallow distance (X-axis) 28.5%; high-to-low distance (Y-axis) 35.2%]. Tunnel placement was evaluated in terms of accuracy and precision. After each ACL reconstruction, results were shown to the surgeon to receive an instant feedback in order to achieve accurate correction and improve tunnel placement for the next surgery. Complications and arthroscopic time were also recorded. RESULTS: Results were divided into three consecutive series (1, 2, 3) of 20 patients each. A trend to placing femoral tunnel slightly shallow in deep-to-shallow distance and slightly high in high-to-low distance was observed in the first and the second series. A progressive improvement in tunnel position was recorded from the first to second series and from the second to the third series. Both accuracy (+52.4%) and precision (+55.7%) increased from the first to the third series (p < 0.001). Arthroscopic time decreased from a mean of 105 min in the first series to 57 min in the third series (p < 0.001). After 50 ACL reconstructions, a satisfactory anatomic femoral tunnel was reached. CONCLUSION: Feedback from post-operative 3D-CT is effective in the learning process to improve accuracy and precision of femoral tunnel placement in order to obtain anatomic ACL reconstruction and helps to reduce also arthroscopic time and learning curve. For clinical relevance, trainee-surgeons should use feedback from post-operative 3DCT to learn anatomic ACL femoral tunnel placement and apply it appropriately. LEVEL OF EVIDENCE: Consecutive case series, Level IV.


Subject(s)
Anterior Cruciate Ligament Injuries/surgery , Anterior Cruciate Ligament Reconstruction/education , Femur/diagnostic imaging , Femur/surgery , Learning Curve , Tomography, X-Ray Computed , Adolescent , Adult , Anterior Cruciate Ligament Reconstruction/standards , Clinical Competence/standards , Epiphyses/surgery , Female , Formative Feedback , Hamstring Muscles/transplantation , Humans , Imaging, Three-Dimensional , Knee Joint/diagnostic imaging , Knee Joint/surgery , Male , Postoperative Period , Young Adult
15.
J Mater Sci Mater Med ; 28(9): 137, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28785889

ABSTRACT

In the last years considerable research and development activity have been expended to find new ceramic bone substitutes for the treatment of bone defects. However in many cases the drawback of synthethic bone substitutes are the slow graft incorporation and remodelling into the host bone. The purpose of this study was to analyze the kinetics of resorption and new bone formation of new calcium sulfate (CaSO4)/calcium phosphate (CaPO4) bioceramic engineered to enhance its bone forming properties. We prospectively evaluated the results of a series of 15 hips with osteonecrosis of the femoral head (ONFH) treated at with core decompression and injection of the CaSO4/CaPO4 composite. In all hips, a quantitative computed tomography (QTC) scan was taken within one week after the surgery, at 12 months, 2 years and finally with a minimum of 4 years follow-up. The mean HU in the immediate post-operative period was 1445 (Range 1388-1602); At one year the mean HU strongly decrease at 556.6 HU (P < 0.01); The mean HU at 2 years follow-up further decreased to 475.1. The mean HU at 4 years was unchanged. The quantitative and qualitative CT scan data of this series indicates that the CaSO4-CaPO4 ceramic composite resorbs over a narrow timeframe and the gradual resorption of the graft within the defect provides an ideal environment for the direct new bone growth that propagates across the defect.


Subject(s)
Bone Substitutes , Calcium Phosphates/chemistry , Calcium Sulfate/chemistry , Ceramics/chemistry , Biocompatible Materials , Femur Head Necrosis/therapy , Humans , Kinetics , Osteogenesis
16.
Knee Surg Sports Traumatol Arthrosc ; 25(4): 1264-1271, 2017 Apr.
Article in English | MEDLINE | ID: mdl-27120190

ABSTRACT

PURPOSE: The anterior cruciate ligament (ACL) reconstruction is one of the most performed and successful orthopaedic procedures. The results are considered independent by the choice of the graft and the fixation devices. A growing interest on resorbable non-metallic fixation devices versus standard metallic fixation devices has been noted over recent years with few clinical experiences reported in the literature. The aim of this study is to compare the clinical and radiological outcomes of patients undergoing ACL reconstruction using autologous hamstring tendons with tibial fixation by a centrally placed resorbable screw and sheath to a combination of an eccentrically placed resorbable interference screw and supplementary staple fixation. METHODS: Ninety patients undergoing an isolated, single-bundle, primary ACL reconstruction with autologous hamstring tendons, using the same femoral fixation, were randomized to a tibial fixation with a centrally placed resorbable screw and sheath, BioIntrafix (group A), or an eccentrically placed resorbable interference screw, BioRCI, and two non-resorbable staples (group B). The latter has represented for many years our standard fixation method. Clinical evaluations (KOOS, IKDC, KT-2000™ side-to-side difference) and radiological analyses were conducted in both groups with a minimum follow-up of 2 years. RESULTS: We assisted in a satisfactory pain relief and functional improvements, without significant clinical and radiological differences in both groups. No further surgery was needed in patients with the screw/sheath tibial fixation. Seven patients with the screw/staples tibial fixation needed the surgical removal of the fixation devices due to pes anserinus irritation or local infection years after the index operation. Other parameters such as the tunnel enlargement were not statistically different in the two groups. CONCLUSIONS: Good clinical and radiological outcomes of ACL reconstruction by a screw/sheath tibial fixation have been reported showing comparable results with respect to screw/staples fixation. There were no failures associated with loss of fixation with either of tibial fixation methods. A fewer number of surgical removals of tibial devices were also recorded in patients treated by the screw/sheath fixation system, related to the absence of local intolerance or infection compared to subjects with a standard tibial fixation.


Subject(s)
Absorbable Implants , Anterior Cruciate Ligament Reconstruction/instrumentation , Anterior Cruciate Ligament Reconstruction/methods , Bone Screws , Surgical Stapling , Adolescent , Adult , Anterior Cruciate Ligament/diagnostic imaging , Anterior Cruciate Ligament/surgery , Female , Femur/diagnostic imaging , Femur/surgery , Humans , Male , Radiography , Tendons/transplantation , Tibia/diagnostic imaging , Tibia/surgery , Transplantation, Autologous , Young Adult
17.
Clin Cases Miner Bone Metab ; 14(1): 40-47, 2017.
Article in English | MEDLINE | ID: mdl-28740524

ABSTRACT

INTRODUCTION: Trochanteric fractures are frequent and generally associated with bone fragility. There is still debate on the best fixation device to treat stable or rather stable trochanteric fractures: we report our clinical and radiological results of fixation with Proximal Femoral Nail "antirotation" (PFNa) in a population of patients compared to a control group treated by Sliding Hip Screw (SHS). MATERIALS AND METHODS: A prospective study was conducted in 71 consecutive patients treated by PFNa (group A), and 69 by a SHS (group B), with a mean age of 81.6 and 83.4 years respectively. Short Form 12 was administered to check postoperative results, and the following parameters were evaluated: range of motion, evaluation of pain, gait ability, X-rays, and Tip Apex Distance Index. RESULTS: A minimum follow-up was conducted in 128 patients: 66 subjects belonging to the PFNa group and 62 to the DHS group. All patients in the group A were able to reach partial or full weight-bearing on the operated leg before leaving the hospital. Forty-four patients (63.8%) of the group B were able to walk with partial weight-bearing before discharge. We recorded 17 complications with a final overall percentage of 17.2% on the overall study population with one single case of failure in both the two groups. DISCUSSION: A statistical significance (p<0.01) of superiority for PFNa was demonstrated regarding surgical time, amplioscope time, intraoperative blood loss, hospital stay, recovery of weight-bearing before discharge. Less significant results (p<0.05) were found for walking ability at the three-months follow-up and patients' satisfaction 6 months after surgery. CONCLUSIONS: PFNa may be considered an useful choice for the treatment of stable or rather stable trochanteric fractures as well as DHS. The light superiority of PFNa may be principally related to its mechanical advantages.

18.
Clin Cases Miner Bone Metab ; 14(2): 197-199, 2017.
Article in English | MEDLINE | ID: mdl-29263733

ABSTRACT

Haemophilia may nowadays be considered an "ortho paedic" disease given due to the involvement of musculoskeletal system in almost all haemophilic subjects. The modern haematological prophylaxis has dramatically improved the quality of life reducing bleedings and life-threatening complications; however, joint bleedings, progressive and irreversible arthropathy and osteoporosis are still now common challenging issues to be faced. One of the tissues involved by Haemophilia is the bone, particularly in the periarticular zone: poor bone quality and decrease of bone stock are typical patterns, and the worse is the arthropathy, the greater the bone loss. The orthopaedic management of such condition is now mandatory and characterized by several surgical techniques. The purpose of this work is to provide an overview of these options derived from our experience in managing haemophilic patients.

19.
Haematologica ; 101(2): 219-25, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26494839

ABSTRACT

Recent evidence suggests that patients with severe hemophilia B may have a less severe disease compared to severe hemophilia A. To investigate clinical, radiological, laboratory and histological differences in the arthropathy of severe hemophilia A and hemophilia B, 70 patients with hemophilia A and 35 with hemophilia B with at least one joint bleeding were consecutively enrolled. Joint bleedings (<10, 10-50, >50), regimen of treatment (prophylaxis/on demand), World Federation of Hemophilia, Pettersson and ultrasound scores, serum soluble RANK ligand and osteoprotegerin were assessed in all patients. RANK, RANK ligand and osteoprotegerin expression was evaluated in synovial tissue from 18 hemophilia A and 4 hemophilia B patients. The percentage of patients with either 10-50 or more than 50 hemarthrosis was greater in hemophilia A than in hemophilia B (P<0.001 and P=0.03, respectively), while that with less than 10 hemarthrosis was higher in hemophilia B (P<0.0001). World Federation of Hemophilia (36.6 vs. 20.2; P<0.0001) and ultrasound (10.9 vs. 4.3; P<0.0001) score mean values were significantly higher in hemophilia A patients. Serum osteoprotegerin and soluble RANK ligand were decreased in hemophilia A versus hemophilia B (P<0.0001 and P=0.006, respectively). Osteoprotegerin expression was markedly reduced in synovial tissue from hemophilia A patients. In conclusion, the reduced number of hemarthrosis, the lower World Federation of Hemophilia and ultrasound scores, and higher osteoprotegerin expression in serum and synovial tissue in hemophilia B suggest that hemophilia B is a less severe disease than hemophilia A. Osteoprotegerin reduction seems to play a pivotal role in the progression of arthropathy in hemophilia A.


Subject(s)
Hemarthrosis/pathology , Hemophilia A/pathology , Hemophilia B/pathology , Osteoprotegerin/genetics , Adolescent , Adult , Aged , Child , Child, Preschool , Disease Progression , Female , Gene Expression , Hemarthrosis/complications , Hemarthrosis/diagnostic imaging , Hemarthrosis/genetics , Hemophilia A/complications , Hemophilia A/diagnostic imaging , Hemophilia A/genetics , Hemophilia B/complications , Hemophilia B/diagnostic imaging , Hemophilia B/genetics , Humans , Joint Capsule/chemistry , Joint Capsule/pathology , Male , Middle Aged , Osteoprotegerin/blood , RANK Ligand/blood , RANK Ligand/genetics , Receptor Activator of Nuclear Factor-kappa B/blood , Receptor Activator of Nuclear Factor-kappa B/genetics , Severity of Illness Index , Ultrasonography
20.
BMC Musculoskelet Disord ; 17(1): 486, 2016 11 23.
Article in English | MEDLINE | ID: mdl-27881114

ABSTRACT

BACKGROUND: All implant compounds undergo an electrochemical process when in contact with biological fluids, as well as mechanical corrosion due to abrasive wear, with production of metal debris that may inhibit repair processes. None of the commonly-used methods can diagnose implant allergies when used singly, therefore a panel of tests should be performed on allergic patients as pre-operative screening, or when a postoperative metal sensitisation is suspected. METHODS: We analysed patients with painful prostheses and subjects prone to allergies using the Patch Test in comparison with the Lymphocyte Transformation Test. Cytokine production was evaluated to identify prognostic markers for early diagnosis of aseptic loosening. Metal debris endocytosis and cytoskeletal rearrangement was visualised by confocal microscopy. RESULTS: Our results demonstrate that the Lymphocyte Transformation Test can identify patients who have a predisposition to develop allergic reactions and can confirm the diagnosis of hypersensitivity in patients with painful prostheses. The prevalence of a Th2-cytokine pattern may be used to identify predisposition to the development of allergic diseases, while the selective presence of osteoclastogenic cytokines may be used as predictor of a negative outcome in patients with painful prosthesis. The hypothesis of the prognostic value of these cytokines as early markers of aseptic loosening is attractive, but its confirmation would require extensive testing. CONCLUSIONS: The Lymphocyte Transformation Test is the most suitable method for testing systemic allergies. We suggest that the combined use of the Patch Test and the Lymphocyte Transformation Test, associated with cytokine detection in selected patients, could provide a useful tool for preventive evaluation of immune reactivity in patients undergoing primary joint replacement surgery, and for clinical monitoring of the possible onset of a metal sensitization in patients with implanted devices.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Hypersensitivity/diagnosis , Metals/adverse effects , Postoperative Complications/diagnosis , Prostheses and Implants/adverse effects , Arthroplasty, Replacement, Knee/instrumentation , Biomarkers/blood , Cytokines/blood , Cytoskeleton/ultrastructure , Endocytosis , Female , Humans , Hypersensitivity/blood , Hypersensitivity/etiology , Lymphocyte Activation , Male , Microscopy, Confocal , Pain/etiology , Pain Measurement , Patch Tests , Postoperative Complications/blood , Postoperative Complications/etiology , Prosthesis Failure , Th2 Cells/metabolism