Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Graefes Arch Clin Exp Ophthalmol ; 262(8): 2651-2659, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38456927

ABSTRACT

PURPOSE: To analyze the radiological features of the lacrimal gland (LG) and extraocular muscle (EOM) in thyroid eye disease (TED) patients with severe subjective dry eye disease (DED) using magnetic resonance imaging (MRI) measurements. METHODS: In this cross-sectional study, mechanical ocular exposure, dry eye assessment and MRI data were collected. Patients were classified into non-severe subjective DED group with ocular surface disease index (OSDI) < 33 and severe subjective DED group with OSDI ≥ 33. Linear regression model was applied for comparing the OSDI < 33 and OSDI ≥ 33 group in TED patients. The predictive performance of MRI parameters and models was assessed by receiver operating characteristic curve (ROC) analysis. RESULTS: Consecutive 88 TED patients (176 eyes) were included in this study. In the OSDI < 33 group, 52 TED patients (104 eyes) with a mean clinical activity score (CAS) of 0.63 ± 0.75. In the OSDI ≥ 33 group, there are 36 TED patients (72 eyes), with a mean CAS of 1.50 ± 1.54. The age and sex of the patients were matched between the two groups. The OSDI ≥ 33 group had shorter tear break-up time, larger levator palpebrae superioris / superior rectus (LPS/SR), inferior rectus and lateral rectus, smaller LG, more inflammatory LPS/SR and inferior rectus than OSDI < 33 DED group (P < 0.05). In the linear regression analysis, compare to the OSDI < 33 DED group, the OSDI ≥ 33 group had larger medial rectus cross-sectional area (ß = 0.06, 95%CI: (0.02, 0.10), P = 0.008), larger inferior rectus cross-sectional area (ß = 0.06, 95%CI: (0.00, 0.12), P = 0.048), smaller LG cross-sectional area (ß = -0.14, 95%CI: (-0.25, -0.04), P = 0.008). In the ROC analysis, the area under curve of medial rectus, inferior rectus, LG, and combined model are 0.625, 0.640, 0.661 and 0.716, respectively. CONCLUSION: Multiparametric MRI parameters of the LG and EOM in TED patients with severe subjective DED were significantly altered. Novel models combining the cross-sectional area of LG, medial rectus and inferior rectus showed good predictive performance in TED patients with severe subjective DED.


Subject(s)
Dry Eye Syndromes , Graves Ophthalmopathy , Lacrimal Apparatus , Multiparametric Magnetic Resonance Imaging , Oculomotor Muscles , ROC Curve , Humans , Oculomotor Muscles/diagnostic imaging , Male , Female , Cross-Sectional Studies , Middle Aged , Graves Ophthalmopathy/diagnosis , Dry Eye Syndromes/diagnosis , Lacrimal Apparatus/diagnostic imaging , Multiparametric Magnetic Resonance Imaging/methods , Adult , Severity of Illness Index , Retrospective Studies , Aged
2.
Int Ophthalmol ; 44(1): 124, 2024 Mar 02.
Article in English | MEDLINE | ID: mdl-38430354

ABSTRACT

PURPOSE: Euthyroid Graves' ophthalmology (EGO) refers to the subgroup of thyroid eye disease patients with distinct clinical presentations. This study evaluated the ocular surface and meibomian gland changes in EGO patients. METHODS: A cross-sectional study was conducted at The Chinese University of Hong Kong including 34 EGO patients and 34 age-and sex- matched healthy controls. Outcome measures include anterior segment examination, keratographic and meibographic imaging. RESULTS: Between 34 EGO patients and 34 age and sex-matched healthy controls, EGO was associated with a higher ocular surface disease index (P < 0.01), higher severity of meibomian gland dropout (upper: P < 0.001, lower: P < 0.00001) and higher percentage of partial blinking (P = 0.0036). The worse affected eyes of the EGO patients were associated with corneal staining (P = 0.0019), eyelid telangiectasia (P = 0.0009), eyelid thickening (P = 0.0013), eyelid irregularity (P = 0.0054), meibomian gland plugging (P < 0.00001), expressibility (P < 0.00001), and meibum quality (P < 0.00001). When the two eyes of the same EGO patient were compared, the degree of meibomian gland dropout was higher among the worse affected eyes (upper: P < 0.00001, and lower: P < 0.00001). Tear meniscus height, lipid layer thickness, and noninvasive break-up time were comparable between the two eyes of EGO patients and also between EGO patients and healthy controls. TMH was positively correlated with the degree of exophthalmos (r = 0.383, P < 0.05). CONCLUSION: EGO patients have more ocular surface complications and meibomian gland dropouts than healthy controls. Almost 60% of them had dry eye symptoms, but aqueous deficiency was not apparent. Further studies are warranted to clarify the mechanism of dry eye in EGO. (249 words).


Subject(s)
Dry Eye Syndromes , Meibomian Glands , Humans , Meibomian Glands/diagnostic imaging , Cross-Sectional Studies , Dry Eye Syndromes/diagnosis , Dry Eye Syndromes/etiology , Blinking , Tears
3.
Polymers (Basel) ; 16(3)2024 Jan 23.
Article in English | MEDLINE | ID: mdl-38337200

ABSTRACT

Infection prevention and public health are a vital concern worldwide, especially during pandemics such as COVID-19 and seasonal influenza. Frequent manual disinfection and use of chemical spray coatings at public facilities are the typical measures taken to protect people from coronaviruses and other pathogens. However, limitations of human resources and coating durability, as well as the safety of disinfectants used are the major concerns in society during a pandemic. Non-leachable antimicrobial agent poly(hexamethylene biguanide) (PHMB) was mixed into photocurable liquid resins to produce novel and tailor-made covers for public facilities via digital light processing, which is a popular 3D printing technique for satisfactory printing resolution. Potent efficacies of the 3D-printed plastics were achieved in standard antibacterial assessments against S. aureus, E. coli and K. pneumoniae. A total of 99.9% of Human coronavirus 229E was killed after being in contact with the 3D-printed samples (containing the promising PHMB formulation) for two hours. In an eight-week field test in Hong Kong Wetland Park, antibacterial performances of the specially designed 3D-printed covers analysed by environmental swabbing were also found to be satisfactory. With these remarkable outcomes, antimicrobial products prepared by digital light processing 3D printing can be regarded as a reliable solution to long-term infection prevention and control.

SELECTION OF CITATIONS
SEARCH DETAIL