Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 104
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Oral Dis ; 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38887830

ABSTRACT

OBJECTIVE: Downregulation of N-myc downstream-regulated gene 2 (NDRG2), a tumor suppressor gene, has been associated with poor clinical outcomes in various cancers. However, the prognostic significance of NDRG2 in oral squamous cell carcinoma (OSCC) remains unknown. This study aimed to evaluate the prognostic value of NDRG2 downregulation in OSCC and to elucidate the mechanism by which NDRG2 is downregulated and the biological role of NDRG2 in tumor progression. METHODS: Immunohistochemical and in silico analyses of NDRG2 expression were performed, and the correlation between NDRG2 expression and clinicopathological data was analyzed. The effect of NDRG2 knockdown on the biological behavior of OSCC cells was investigated and the effect of 5-aza-2'-deoxycytidine (5-aza-dC) on NDRG2 expression was determined. RESULTS: NDRG2 expression was significantly downregulated and DNA hypermethylation of NDRG2 was frequently found in head and neck SCC, including OSCC. Low NDRG2 expression was significantly correlated with adverse clinicopathological features and worse survival in OSCC. NDRG2 knockdown could enhance the oncogenic properties of OSCC cells. NDRG2 mRNA levels in OSCC cells could be restored by 5-aza-dC. CONCLUSION: Downregulation of NDRG2 promotes tumor progression and predicts poor prognosis in OSCC. Therefore, restoration of NDRG2 expression may be a potential therapeutic strategy in OSCC.

2.
Eur Radiol ; 33(1): 172-180, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35976400

ABSTRACT

OBJECTIVES: To evaluate the diagnostic performance of 2021 K-TIRADS biopsy criteria for detecting malignant thyroid nodules in a pediatric population, making comparisons with 2016 K-TIRADS. METHODS: This retrospective study included pediatric patients with histopathologically confirmed diagnoses. The diagnostic performance of 2021 K-TIRADS was compared with that of 2016 K-TIRADS. Simulation studies were performed by changing biopsy cut-off sizes for K-TIRADS 5 to 1.0 cm (K-TIRADS5-1.0cm) and 0.5 cm (K-TIRADS5-0.5cm), and for K-TIRADS 4 to 1.0 cm (K-TIRADS4-1.0cm) and 1.0-1.5 cm (K-TIRADS4-1.0~1.5cm). Subgroup analysis was performed in small (< 1.5 cm) and large nodules (≥ 1.5 cm). RESULTS: Two hundred seventy-seven thyroid nodules (54.9% malignant) from 221 pediatric patients were analyzed. All simulated 2021 K-TIRADS showed higher accuracy than 2016 K-TIRADS. Compared with 2021 K-TIRADS5-1.0cm, 2021 K-TIRADS5-0.5cm showed lower specificity (51.6% vs. 47.9%; p = 0.004) but higher sensitivity (77.2% vs. 90.3%; p < 0.001) and accuracy (62.7% vs. 68.9%; p < 0.001). Compared with 2021 K-TIRADS4-1.0cm, 2021 K-TIRADS4-1.0~1.5cm showed higher specificity (44.9% vs. 47.9%; p = 0.018) without significant difference in other diagnostic measures. Compared with 2016 K-TIRADS, 2021 K-TIRADS (biopsy cut-offs, 0.5 cm for K-TIRADS 5; 1.0-1.5 cm for K-TIRADS 4) showed higher sensitivity (34.0% vs. 67.3%; p < 0.001) while maintaining specificity (89.4% vs. 88.2%; p = 0.790) in small nodules, and higher specificity (5.9% vs. 25.4%; p < 0.001) while maintaining sensitivity (100% vs. 98.7%; p = 0.132) in large nodules. CONCLUSIONS: In pediatric patients, 2021 K-TIRADS showed superior diagnostic accuracy to 2016 K-TIRADS, especially with a biopsy cut-off of 0.5 cm for K-TIRADS 5 and 1.0-1.5 cm for K-TIRADS 4. KEY POINTS: • All simulated 2021 K-TIRADS showed higher accuracy than 2016 K-TIRADS. • 2021 K-TIRADS with cut-off size for K-TIRADS 5 of 0.5 cm showed lower specificity but higher sensitivity and accuracy than that of 1.0 cm. • Compared with 2016 K-TIRADS, 2021 K-TIRADS (biopsy cut-offs, 0.5 cm for K-TIRADS 5; 1.0-1.5 cm for K-TIRADS 4) showed higher sensitivity while maintaining specificity in small nodules, and higher specificity while maintaining sensitivity in large nodules.


Subject(s)
Thyroid Neoplasms , Thyroid Nodule , Humans , Child , Thyroid Nodule/diagnostic imaging , Retrospective Studies , Thyroid Neoplasms/pathology , Ultrasonography/methods , Risk Assessment/methods , Republic of Korea/epidemiology
3.
J Eur Acad Dermatol Venereol ; 37(1): 75-84, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36028994

ABSTRACT

BACKGROUND: Psoriasis has a devastating psychological impact on patients' quality of life. However, the relationship between suicidality and psoriasis remains unclear. OBJECTIVE: This study analysed and compared the risk of suicidality (suicidal ideation, suicide attempt and completed suicide) between patients with psoriasis and the general population. METHODS: This nationwide, population-based, retrospective, cohort study analysed the Korean National Health Insurance Service claim data from 2005 to 2018. RESULTS: The study included 348,439 patients with psoriasis aged over 18 years and with age- and sex-matched controls. The risk of suicidality was higher in the psoriasis group than in the control group [adjusted hazard ratio (aHR) 1.21; 95% confidence interval (CI), 1.18-1.24]. The aHR of suicidality was higher in the psoriatic arthritis group (aHR, 1.46; 95% CI, 1.39-1.54) than in the psoriasis-alone group (aHR, 1.17; 95% CI, 1.13-1.20). However, the severity of psoriasis and suicidality showed no correlation (mild psoriasis group: aHR, 1.22; 95% CI, 1.18-1.25; moderate-to-severe psoriasis group: aHR, 1.16; 95% CI, 1.10-1.23). CONCLUSION: Patients with psoriasis have an increased risk of suicidality. In particular, the presence of arthritis in patients had a more significant effect on the risk of suicidality.


Subject(s)
Psoriasis , Suicide , Humans , Adult , Middle Aged , Suicidal Ideation , Cohort Studies , Retrospective Studies , Quality of Life , Psoriasis/complications , Psoriasis/epidemiology , Psoriasis/psychology , Republic of Korea/epidemiology , Risk Factors , Incidence
4.
Radiology ; 305(1): 190-198, 2022 10.
Article in English | MEDLINE | ID: mdl-35787203

ABSTRACT

Background The validation of adult-based US risk stratification systems (RSSs) in the discrimination of malignant thyroid nodules in a pediatric population remains lacking. Purpose To estimate and compare the diagnostic performance of pediatric US RSSs based on five adult-based RSSs in the discrimination of malignant thyroid nodules in a pediatric sample. Materials and methods Pediatric patients (age ≤18 years) with histopathologically confirmed US-detected thyroid nodules at a tertiary referral hospital between January 2000 and April 2020 were analyzed retrospectively. The diagnostic performance of US-based fine-needle aspiration biopsy (FNAB) criteria in thyroid cancer detection was estimated. The following sensitivity analyses were performed: (a) scenario 1: nodules smaller than 1 cm, with the highest category additionally biopsied; (b) scenario 2, application of American College of Radiology Thyroid Imaging Reporting and Data System nodule size cutoffs to other RSSs; (c) scenario 3, scenarios 1 and 2 together. Generalized estimating equations (GEEs) were used for estimation. Results A total of 277 thyroid nodules in 221 pediatric patients (median age, 16 years [interquartile range {IQR}, 13-17]; 172 female; 152 of 277 patients [55%] malignant) were analyzed. The GEE-estimated sensitivity and specificity ranged from 70% to 78% (104 to 119 of 152 patients, based on each reader's interpretation) and from 42% to 78% (49 of 124 patients to 103 of 125 patients). In scenario 1, the missed malignancy rate was reduced from 32%-38% (41 of 134 patients to 34 of 83 patients) to 15%-21% (eight of 59 patients to 28 of 127 patients). In scenario 2, the unnecessary biopsy rate was reduced from 35%-39% (60 of 176 patients to 68 of 175 patients) to 20%-34% (18 of 109 patients to 62 of 179 patients). The highest accuracy was noted in scenario 3 (range, 71%-81%; 199 of 277 patients to 216 of 262 patients). Conclusion The diagnostic performances of the fine-needle aspiration biopsy criteria of five adult-based risk stratification systems were acceptable in the pediatric population and were improved by applying the American College of Radiology Thyroid Imaging Reporting and Data System size cutoff for nodules 1 cm or larger and allowing biopsy of the highest category nodules smaller than 1 cm. © RSNA, 2022 Online supplemental material is available for this article.


Subject(s)
Thyroid Neoplasms , Thyroid Nodule , Adolescent , Adult , Biopsy, Fine-Needle , Child , Female , Humans , Reproducibility of Results , Retrospective Studies , Risk Assessment , Thyroid Neoplasms/diagnostic imaging , Thyroid Neoplasms/pathology , Thyroid Nodule/diagnostic imaging , Thyroid Nodule/pathology , Ultrasonography/methods
5.
J Pediatr ; 251: 89-97.e3, 2022 12.
Article in English | MEDLINE | ID: mdl-35944713

ABSTRACT

OBJECTIVE: To evaluate associations between postnatal imaging features and outcome of left-sided congenital diaphragmatic hernia, as defined by overall survival and a requirement for extracorporeal membrane oxygenation (ECMO). STUDY DESIGN: Newborns diagnosed prenatally with left-sided congenital diaphragmatic hernia between January 2013 and September 2021 were studied retrospectively. The esophageal deviation index was newly defined as the largest diameter from the midline to deviated gastric tube divided by the largest transverse diameter of the thoracic cavity on the radiograph. Regression analyses were performed to identify postnatal imaging features associated with overall survival and a requirement for ECMO. The predictive power (ie, area under the curve [AUC] of a time-dependent receiver operating characteristic curve) of prenatal, postnatal, and intraoperative findings for predicting survival were calculated. RESULTS: Ninety-seven patients (54 males; mean gestational age, 38.3 ± 1.9 weeks; mean birth weight, 2956.5 ± 540.0 g) were analyzed. The esophageal deviation index (adjusted hazard ratio [HR], moderate [≥0.19 to <0.24], 6.427 [P = .029]; severe [≥0.24], 33.007 [P < .001]) and right pneumothorax (adjusted HR, 8.763; P = .002) were associated with overall survival and with a requirement for ECMO. Liver herniation on postnatal ultrasound also was associated with overall survival (P < .001) and need for ECMO (P = .001). In addition, the AUC for prediction of 1-year survival from postnatal ultrasound was comparable with that of prenatally or intraoperatively detected liver herniation (0.93; 95% CI, 0.88-0.97). CONCLUSIONS: The esophageal deviation index, right pneumothorax, and liver herniation observed by postnatal imaging have prognostic value in patients with left-sided congenital diaphragmatic hernia.


Subject(s)
Hernias, Diaphragmatic, Congenital , Pneumothorax , Pregnancy , Male , Female , Humans , Infant, Newborn , Infant , Hernias, Diaphragmatic, Congenital/diagnostic imaging , Hernias, Diaphragmatic, Congenital/surgery , Retrospective Studies , Ultrasonography, Prenatal/methods , Liver/diagnostic imaging
6.
Eur Radiol ; 31(10): 7450-7463, 2021 Oct.
Article in English | MEDLINE | ID: mdl-33864505

ABSTRACT

OBJECTIVES: To evaluate the diagnostic performance of adult-based "American College of Radiology- Thyroid Imaging Reporting And Data System" (ACR-TIRADS) and "American Thyroid Association" (ATA) in the pediatric population. METHODS: MEDLINE/PubMed, EMBASE, Cochrane Library, and Web of Science databases were searched for articles investigating the diagnostic performance of each stratification system (ACR-TIRADS or ATA) and evaluated them according to three aspects: (a) the risk of malignancy in each category; (b) diagnostic performance using the classic indicators (sensitivity, specificity); and (c) diagnostic performance regarding fine needle aspiration/biopsy recommendation. In addition to pathologic diagnosis, we allowed imaging follow-up as the reference standard for benign nodules. RESULTS: Eight articles (1036 thyroid nodules) were included. For ACR-TIRADS, the pooled risk of malignancy in category was as follows: category 5 (59.3%); 4 (20.7%); 3 (11.0%); 2 (6.0%), and 1 (5.5%). For nodules of high suspicion of malignancy (category 4 or 5), the pooled sensitivity and specificity were 0.84 and 0.64. For ATA, the pooled risk of malignancy was as follows: category 5 (55.4%); 4 (34.2%); 3 (12.2%); and 2 (7.5%). For nodules of high suspicion of malignancy (category 4 or 5), the pooled sensitivity and specificity were 0.90 and 0.50. For category 5 nodules, the pooled specificity was significantly higher in ACR-TIRADS (p = 0.02). For ACR-TIRADS, the missed malignancy rate was 21.7% and the unnecessary biopsy rate was 62.7%. Information was not sufficient for this calculation with ATA. CONCLUSIONS: The diagnostic performance of ACR-TIRADS and ATA in the pediatric population was somewhat modest. Large studies are mandatory for further validation and future amendments. KEY POINTS: • The pooled sensitivity and specificity for highly suspicious nodules (category 4 or 5) for ACR-TIRADS were 0.84 and 0.64, and for ATA were 0.90 and 0.50, respectively. • When applying ACR-TIRADS for children, the pooled missed malignancy rate (21.7%) and unnecessary biopsy rates (62.7%) are still reasonably high. Insufficient information was available to perform these calculations for the ATA system. • Current risk stratification systems, especially ACR-TIRADS, require modification by focusing more on increasing the sensitivity and decreasing the missed malignancy rate. Lowering size cut-off for biopsy would be a reasonable option.


Subject(s)
Thyroid Neoplasms , Thyroid Nodule , Adult , Biopsy, Fine-Needle , Child , Humans , Retrospective Studies , Risk Assessment , Thyroid Nodule/diagnostic imaging , Ultrasonography , United States
7.
Eur Radiol ; 31(11): 8081-8097, 2021 Nov.
Article in English | MEDLINE | ID: mdl-33974147

ABSTRACT

OBJECTIVE: To identify predictors of failed enema reduction in children with intussusception. METHODS: PubMed and EMBASE were searched for all studies published over a 20-year time frame, prior to March 25, 2020. Original articles that reported predictors of failed enema reduction were included. The pooled odds ratio (OR) for successful enema reduction according to various features was calculated. The combined estimates were meta-analytically pooled by random-effects modeling. The risk of bias was assessed using the National Institute of Health Quality Assessment Tool. This review was registered to the PROSPERO (CRD42020190178). RESULTS: A total of 38 studies, comprising 40,133 cases, were included. The shorter duration of symptoms (< 24 h; combined OR, 3.812; 95% CI, 2.150-6.759) and abdominal pain (combined OR, 2.098; 95% CI, 1.405-3.133) were associated with the success (all p < 0.001). Age < 1 year (combined OR, 0.385; 95% CI, 0.166-0.893; p = 0.026), fever (combined OR, 0.519; 95% CI, 0.371-0.725; p < 0.001), rectal bleeding (combined OR, 0.252; 95% CI, 0.165-0.387; p < 0.001), and vomiting (combined OR, 0.497; 95% CI, 0.372-0.664; p < 0.001) were associated with the failed reduction. The ascites (combined OR, 0.127; 95% CI, 0.044-0.368; p = 0.001), left-sided intussusception (combined OR, 0.121; 95% CI, 0.058-0.252; p < 0.001), and trapped fluid (combined OR, 0.179; 95% CI, 0.061-0.525; p = 0.017) on US were associated with the failed reduction. CONCLUSIONS: Successful predictors for intussusception reduction have been summarized. This evidence can help identify patients who are more likely to fail non-operative reduction and could be potential surgical candidates. KEY POINTS: • A shorter duration of symptoms and presence of abdominal pain were associated with increased probability of success. • Age (less than 1 year), presence of fever, rectal bleeding, vomiting, and presence of ascites, left-sided intussusception, or trapped fluid on ultrasonography were associated with decreased probability of success. • This study suggests that various clinical and ultrasonography predictors would help identify patients who are more likely to fail nonoperative reduction and identify potential preoperative candidates.


Subject(s)
Intussusception , Child , Enema , Humans , Infant , Intussusception/complications , Intussusception/diagnostic imaging , Intussusception/therapy , Odds Ratio , Retrospective Studies , Ultrasonography
8.
Eur Radiol ; 31(12): 8850-8857, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34031749

ABSTRACT

OBJECTIVES: To evaluate the outcome of staging chest CT and to identify clinicoradiological factors predictive of lung metastasis in patients with hepatoblastoma based on the 2017 PRE-Treatment EXTent of tumor (PRETEXT) system. METHODS: This bi-center study retrospectively identified patients diagnosed with hepatoblastoma between January 1998 and September 2019 in two tertiary hospitals. The primary outcome was the proportion of the patients who had lung metastasis at staging chest CT. The diagnostic accuracy of staging chest CT was calculated based on the 2017 PRETEXT criteria. The secondary outcome was the identification of factors predictive of lung metastasis using multivariable logistic regression. RESULTS: In total, 123 patients (median age, 1 year; interquartile range, 0-4 years; 59 female) were included. Among those, 28% (35/123; 95% confidence interval [CI], 21-37%) had lung metastasis at staging chest CT. The overall accuracy of staging chest CT was 96.8%. The proportion of lung metastasis in patients with stage I, II, III, and IV was 0%, 24% (12 of 49; 95% CI, 14-38%), 23% (9 of 40; 95% CI, 12-38%), and 56% (14 of 25; 95% CI, 37-73%), respectively. Multifocality (adjusted odds ratio, 6.7; 95% CI, 2.7-17.5; p < .001) and male sex (adjusted odds ratio, 3.1; 95% CI, 1.2-8.6; p = .02) were associated with the presence of lung metastasis. CONCLUSIONS: Twenty-eight percent of the patients with hepatoblastoma had lung metastasis at staging chest CT. Multifocality and male sex were predictive factors for lung metastasis on staging chest CT. KEY POINTS: • The proportion of lung metastasis in patients with hepatoblastoma was 28%. • The overall accuracy of staging chest CT was 97% based on the 2017 PRETEXT system. • Hepatic tumor multifocality and male sex were predictors of lung metastasis.


Subject(s)
Hepatoblastoma , Liver Neoplasms , Lung Neoplasms , Child , Female , Hepatoblastoma/diagnostic imaging , Hepatoblastoma/pathology , Humans , Infant , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/pathology , Lung Neoplasms/diagnostic imaging , Male , Neoplasm Staging , Prognosis , Retrospective Studies , Tomography, X-Ray Computed
9.
Environ Health ; 20(1): 6, 2021 01 07.
Article in English | MEDLINE | ID: mdl-33413431

ABSTRACT

BACKGROUND: Air pollution is a major issue that poses a health threat worldwide. Although several studies investigated the adverse effects of air pollution on various diseases, few have directly demonstrated the effects on pneumonia. Therefore, we performed a systematic review and meta-analysis on the associations between short-term exposure of air pollutants and hospital admission or emergency room (ER) visit for pneumonia. METHODS: A literature search was performed using PubMed, Embase, and Web of Science up to April 10, 2020. Pooled estimates were calculated as % increase with 95% confidence intervals using a random-effects model. A sensitivity analysis using the leave-one-out method and subgroup analysis by region were performed. RESULTS: A total of 21 studies were included in the analysis. Every 10 µg/m3 increment in PM2.5 and PM10 resulted in a 1.0% (95% CI: 0.5-1.5) and 0.4% (95% CI: 0.2-0.6) increase in hospital admission or ER visit for pneumonia, respectively. Every 1 ppm increase of CO and 10 ppb increase of NO2, SO2, and O3 was associated with 4.2% (95% CI: 0.6-7.9), 3.2% (95% CI: 1.3-5.1), 2.4% (95% CI: - 2.0-7.1), and 0.4% (95% CI: 0-0.8) increase in pneumonia-specific hospital admission or ER visit, respectively. Except for CO, the sensitivity analyses yielded similar results, demonstrating the robustness of the results. In a subgroup analysis by region, PM2.5 increased hospital admission or ER visit for pneumonia in East Asia but not in North America. CONCLUSION: By combining the inconsistent findings of several studies, this study revealed the associations between short-term exposure of air pollutants and pneumonia-specific hospital admission or ER visit, especially for PM and NO2. Based on the results, stricter intervention policies regarding air pollution and programs for protecting human respiratory health should be implemented.


Subject(s)
Air Pollution/adverse effects , Emergency Service, Hospital/statistics & numerical data , Environmental Exposure/adverse effects , Hospitalization/statistics & numerical data , Pneumonia/epidemiology , Air Pollutants/adverse effects , Carbon Monoxide/adverse effects , Humans , Nitrogen Dioxide/adverse effects , Particulate Matter/adverse effects
10.
Acta Radiol ; 62(4): 541-550, 2021 Apr.
Article in English | MEDLINE | ID: mdl-32498544

ABSTRACT

BACKGROUND: Respiratory artifacts impair image quality of magnetic resonance imaging (MRI) in children who cannot hold breath during MRI examination. PURPOSE: To compare the quality of free-breathing contrast-enhanced 3D T1-weighted (T1W) images of the upper abdomen in children using Cartesian acquisition (Cartesian eTHRIVE), stack-of-stars acquisition with spectral fat suppression (3D VANE eTHRIVE), and stack-of-stars acquisition with fat suppression using modified Dixon (3D VANE mDixon). MATERIAL AND METHODS: Pediatric patients (aged <19 years) who underwent whole-body MRI with free-breathing contrast-enhanced T1W axial scans of upper abdomen using Cartesian eTHRIVE, 3D VANE eTHRIVE, and 3D VANE mDixon were enrolled. Image quality parameters were assessed including overall image quality, hepatic edge sharpness, hepatic vessel clarity, respiratory artifacts, radial artifacts, lesion conspicuity, and lesion edge sharpness using the Likert scale, where a lower score indicated poorer image quality. The coefficients of variation of signal intensity of liver and spleen were analyzed. RESULTS: In 41 patients, 3D VANE eTHRIVE showed the highest scores for all image quality parameters (P ≤ 0.001). 3D VANE eTHRIVE also showed higher scores for respiratory (P ≤ 0.001) and radial artefacts than 3D VANE mDixon (P = 0.001). There were no significant differences in coefficients of variation of signal intensity of the liver and spleen between 3D VANE eTHRIVE and 3D VANE mDixon. Acquisition time was longer for 3D VANE eTHRIVE (81.26 ± 16 s) than for Cartesian eTHRIVE (7.87 ± 0.95 s) and 3D VANE mDixon (76.66 ± 12.4 s, P < 0.001). CONCLUSION: The application of stack-of-stars acquisition to 3D T1W abdominal MRI resulted in better image quality than Cartesian acquisition in free-breathing children. In stack-of-stars acquisition, spectral fat suppression resulted in better image quality and fewer artifacts than mDixon.


Subject(s)
Abdomen/diagnostic imaging , Contrast Media , Imaging, Three-Dimensional , Magnetic Resonance Imaging/methods , Abdominal Fat , Artifacts , Child , Child, Preschool , Female , Humans , Infant , Male , Respiration , Retrospective Studies
11.
Acta Radiol ; 62(8): 1088-1096, 2021 Aug.
Article in English | MEDLINE | ID: mdl-32811156

ABSTRACT

BACKGROUND: Validated non-invasive examinations are necessary to monitor liver fibrosis in children with biliary atresia (BA) after the Kasai procedure. PURPOSE: To evaluate the diagnostic accuracy of two-dimensional shear wave elastography (2D-SWE), transient elastography (TE), and the serologic biomarkers of aspartate transaminase-to-platelet ratio index (APRI) and Fibrosis-4 (FIB-4) score for evaluating native liver fibrosis in children with BA. MATERIAL AND METHODS: We retrospectively reviewed same-day 2D-SWE and TE liver stiffness (LS) measurements of 63 patients with BA who underwent the Kasai procedure. The APRI and FIB-4 score were computed. Hepatic fibrosis was categorized into three clinical categories based on the ultrasound (US) hepatic morphology and clinical manifestations of liver cirrhosis: I, pre-cirrhotic liver state (n = 15); II, US and/or clinical signs of liver cirrhosis with compensated liver function (n = 27); and III, liver cirrhosis with decompensated liver function (n = 21). We compared area under the receiver operating characteristic curve (AUC) data among 2D-SWE, TE, APRI, and FIB-4 score. Combined evaluation of serologic fibrosis indices and US elastography was conducted and AUCs of combinations were analyzed. RESULTS: 2D-SWE, TE, APRI, and FIB-4 score showed good to excellent diagnostic accuracy for differentiating clinical categories (AUCs 0.779-0.955). AUC values were significantly increased after adding TE to FIB-4 score for detecting liver cirrhosis (P = 0.02). CONCLUSION: 2D-SWE, TE, APRI, and FIB-4 score are accurate non-invasive markers for monitoring native liver fibrosis in patients with BA. Combined use of serologic markers and US elastography could yield more accurate diagnoses of liver fibrosis than serologic markers alone.


Subject(s)
Biliary Atresia/surgery , Elasticity Imaging Techniques/methods , Liver Cirrhosis/diagnosis , Portoenterostomy, Hepatic/adverse effects , Ultrasonography/methods , Adolescent , Aspartate Aminotransferases/blood , Biomarkers/blood , Child , Child, Preschool , Humans , Infant , Liver Cirrhosis/blood , Liver Cirrhosis/diagnostic imaging , Liver Cirrhosis/etiology , Platelet Count , Portoenterostomy, Hepatic/methods , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity , Young Adult
12.
J Ultrasound Med ; 39(2): 311-321, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31392769

ABSTRACT

OBJECTIVES: To compare the feasibility and clinical applicability of ElastQ imaging (Philips Healthcare, Best, the Netherlands) with that of SuperSonic shear imaging (SSI; SuperSonic Imagine, Aix-en-Provence, France) using an elastographic phantom and a pilot study of patients. METHODS: Two-dimensional shear wave elastography measurement was performed by ElastQ imaging and SSI by 2 radiologists. An elastographic phantom with 5 target elasticities at 2 acquisition depths was used. The coefficients of variation and intraclass correlation coefficients (ICCs) were evaluated for repeatability and interobserver agreement, respectively. The mean elasticities of the systems at each target were compared. The proportions of measurements that were out of the range of expected values and measurement errors were calculated to determine accuracy. Liver stiffness (LS) was measured by both systems in 27 children and young adult patients with various liver diseases. RESULTS: Both systems provided high repeatability in elasticity measurements of phantom targets (coefficients of variation, 0.69%-15.82%), and there was excellent interobserver agreement (ICC, 0.992). Most (90%) mean elasticities of targets were significantly different between the techniques (P ≤ .002) and acquisition depths (P ≤ .004). ElastQ imaging had significantly lower proportions of out-of-range measurements and measurement errors (P ≤ .003) than SSI. In patients with liver disease, LS measurements of the systems were strongly correlated (ρ = 0.955; P < .001) and had excellent agreement (ICC, 0.951; P < .001). CONCLUSIONS: ElastQ imaging had comparably good results in terms of repeatability, interobserver agreement, and accuracy in the phantom model compared with SSI. The pilot patient study showed strong correlations in LS values between the systems.


Subject(s)
Elasticity Imaging Techniques/methods , Liver Diseases/diagnostic imaging , Child , Elastic Modulus , Female , Humans , Male , Phantoms, Imaging , Pilot Projects , Retrospective Studies
13.
J Ultrasound Med ; 39(11): 2231-2242, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32401363

ABSTRACT

OBJECTIVES: To investigate the diagnostic value of transient elastography (TE), 2-dimensional (2D) shear wave elastography (SWE), and the serologic fibrosis indices aspartate transaminase-to-platelet ratio index (APRI) and Fibrosis-4 (FIB-4) score for Wilson disease (WD). METHODS: We retrospectively identified patients with a diagnosis of WD who underwent TE and 2D SWE on the same day. Their APRI and FIB-4 scores were calculated. Hepatic involvement was classified into 5 clinical categories (I-V) based on the laboratory findings, hepatic morphologic characteristics on ultrasound (US) imaging, and clinical symptoms of cirrhosis: I, normal (n = 17); II, only biochemical abnormality (n = 15); III, altered hepatic morphologic characteristics (n = 10); IV, compensated liver cirrhosis (n = 3); and V, decompensated liver cirrhosis (n = 0). We compared the area under the receiver operating characteristic curve (AUROC) data for TE, 2D SWE, the APRI, and the FIB-4 score. A combined assessment of the serologic markers and US elastography was performed, and the AUROCs of the combinations were compared. RESULTS: Forty-five patients were included in the study (median age, 16.0 years; range, 3-35 years). Transient elastography, 2D SWE, and APRI were comparable in distinguishing the clinical categories (AUROC, 0.799-0.928). The FIB-4 score showed lower diagnostic value in distinguishing clinical category I from the other categories (AUROC, 0.647). Combining the serologic markers and US elastography significantly increased the AUROC value of the FIB-4 score (with TE and 2D SWE, P = .01 and .02). CONCLUSIONS: Transient elastography and 2D SWE showed excellent diagnostic accuracy for differentiating the clinical categories of hepatic involvement. The APRI showed better diagnostic performance than the FIB-4 score. The assessment of hepatic manifestations in WD can be improved by combining US elastography with serologic indices.


Subject(s)
Elasticity Imaging Techniques , Hepatolenticular Degeneration , Adolescent , Adult , Aspartate Aminotransferases , Child , Child, Preschool , Hepatolenticular Degeneration/diagnostic imaging , Hepatolenticular Degeneration/pathology , Humans , Liver Cirrhosis , Retrospective Studies , Young Adult
14.
Psychol Med ; 49(13): 2177-2185, 2019 10.
Article in English | MEDLINE | ID: mdl-30326977

ABSTRACT

BACKGROUND: Given its diverse disease courses and symptom presentations, multiple phenotype dimensions with different biological underpinnings are expected with bipolar disorders (BPs). In this study, we aimed to identify lifetime BP psychopathology dimensions. We also explored the differing associations with bipolar I (BP-I) and bipolar II (BP-II) disorders. METHODS: We included a total of 307 subjects with BPs in the analysis. For the factor analysis, we chose six variables related to clinical courses, 29 indicators covering lifetime symptoms of mood episodes, and 6 specific comorbid conditions. To determine the relationships among the identified phenotypic dimensions and their effects on differentiating BP subtypes, we applied structural equation modeling. RESULTS: We selected a six-factor solution through scree plot, Velicer's minimum average partial test, and face validity evaluations; the six factors were cyclicity, depression, atypical vegetative symptoms, elation, psychotic/irritable mania, and comorbidity. In the path analysis, five factors excluding atypical vegetative symptoms were associated with one another. Cyclicity, depression, and comorbidity had positive associations, and they correlated negatively with psychotic/irritable mania; elation showed positive correlations with cyclicity and psychotic/irritable mania. Depression, cyclicity, and comorbidity were stronger in BP-II than in BP-I, and they contributed significantly to the distinction between the two disorders. CONCLUSIONS: We identified six phenotype dimensions; in addition to symptom features of manic and depressive episodes, various comorbidities and high cyclicity constructed separate dimensions. Except for atypical vegetative symptoms, all factors showed a complex interdependency and played roles in discriminating BP-II from BP-I.


Subject(s)
Bipolar Disorder/psychology , Depression/psychology , Adult , Aged , Comorbidity , Factor Analysis, Statistical , Female , Humans , Male , Middle Aged , Phenotype , Psychopathology , Republic of Korea
15.
Eur Radiol ; 29(5): 2560-2572, 2019 May.
Article in English | MEDLINE | ID: mdl-30617493

ABSTRACT

OBJECTIVE: To assess the technical performance (proportion of technical failure and unreliable measurements) of shear wave elastography (SWE) for assessing liver stiffness in pediatric and adolescent patients. METHODS: We searched Ovid-MEDLINE and EMBASE databases for eligible studies and selected original articles investigating transient elastography (TE), point shear wave elastography (pSWE), or two-dimensional SWE (2D-SWE) for measuring liver stiffness in pediatric and adolescent patients. A quantitative synthesis of studies reporting technical failures and/or unreliable measurements of TE, pSWE, or 2D-SWE is presented. Meta-analytic pooling was conducted using the random effects model. Meta-regression analysis was conducted to explore potential causes of heterogeneity. RESULTS: Forty of 69 studies (58%) provided technical performance information. Technical failure data were reported in 3 TE, 6 pSWE, and 8 2D-SWE studies. Unreliable measurement data were provided in 21 TE, 4 pSWE, and 1 2D-SWE study. The pooled proportion of unreliable measurements of TE was 12.1%. Meta-regression analysis showed that the study population size and readers' blinding to pathologic results affected the study's heterogeneity. The pooled proportions of technical failure during pSWE and 2D-SWE were 4.1% and 2.2%, respectively, demonstrating no significant difference between the techniques. CONCLUSIONS: We reviewed the technical performance of SWE, especially the rate of unreliable measurements from TE studies and rates of technical failure from pSWE and 2D-SWE studies. Considering the importance of technical performance for clinical validation of SWE, numbers of and reasons for technical failure and unreliable measurements should be reported in future studies. Further efforts are necessary to standardize SWE reliability criteria. KEY POINTS: • Most TE studies reported rate of unreliable measurements, whereas pSWE and 2D-SWE studies were likely to report rates of technical failure. • The pooled proportion of unreliable measurements of TE was 12.1%. • The pooled proportions of technical failure during pSWE and 2D-SWE were 4.1% and 2.2%, respectively, demonstrating no significant difference between the techniques.


Subject(s)
Elasticity Imaging Techniques/methods , Liver Cirrhosis/diagnosis , Liver/diagnostic imaging , Adolescent , Child , Elasticity , Humans , Liver/physiopathology , Liver Cirrhosis/pathology , Reproducibility of Results
16.
J Ultrasound Med ; 38(3): 747-759, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30117178

ABSTRACT

OBJECTIVES: To assess the diagnostic performance of ultrasound (US) elastography in evaluating portal hypertension in children and compare the liver and spleen stiffness values between the portal hypertension and control groups. METHODS: Studies in the MEDLINE and Embase databases were selected that investigated the diagnostic performance of US elastography in children with portal hypertension up to December 21, 2017. Pooled sensitivity and specificity data were assessed by hierarchical logistic regression modeling. RESULTS: Eleven studies were included in the systematic review, and a meta-analysis could be conducted in 7 of these publications to evaluate the diagnostic performance of US elastography. The summary sensitivity and specificity of this method for liver stiffness were 90% (95% confidence interval [CI], 83%-94%) and 79% (95% CI, 73%-84%), respectively, and the area under the hierarchical summary receiver operating characteristic curve was 0.92 (95% CI, 0.90-0.94). A subgroup analysis of 5 transient elastographic studies revealed similar diagnostic performance (sensitivity, 90%; specificity, 78%). In 10 of the 11 studies that investigated liver stiffness and 2 of the 3 studies that also measured spleen stiffness, patients in the portal hypertension group had a significantly higher stiffness value than the control group (P < .05). CONCLUSIONS: Ultrasound elastography shows good performance in diagnosing portal hypertension and can identify significant differences in liver and spleen stiffness in children with this condition. This method thus has considerable potential as a noninvasive tool for screening portal hypertension-related complications in children with chronic liver disease.


Subject(s)
Elasticity Imaging Techniques/methods , Hypertension, Portal/diagnostic imaging , Liver/diagnostic imaging , Liver/pathology , Spleen/diagnostic imaging , Spleen/pathology , Adolescent , Adult , Child , Child, Preschool , Databases, Factual , Humans , Hypertension, Portal/pathology , Infant , Reproducibility of Results , Sensitivity and Specificity , Young Adult
17.
Radiology ; 288(1): 262-269, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29634437

ABSTRACT

Purpose To develop and validate a scoring system based on clinical and imaging features to predict the risk for biliary atresia in patients with neonatal cholestasis. Materials and Methods Patients with neonatal cholestasis who underwent both ultrasonography (US) and hepatobiliary scintigraphy (n = 480) were retrospectively identified from two tertiary referral hospitals from January 2000 to February 2017. Patients from one hospital were classified as the derivation cohort (n = 371), and those from the other hospital were classified as the validation cohort (n = 109). Clinical and imaging features associated with biliary atresia were assessed. Histopathologic or intraoperative cholangiographic findings served as the reference standard for biliary atresia. A prediction model was developed by using logistic regression and was then transformed into a scoring system. The scoring system was internally and externally validated. Results Among the 371 patients in the derivation cohort, 97 (26.15%) had biliary atresia. A scoring system was constructed with the following variables: full-term birth, presence of the triangular cord sign at US, abnormal gallbladder morphology at US, and failure of radioisotope excretion to the small bowel at hepatobiliary scintigraphy. The maximum possible score with this system is 7 points. This system enabled differentiation of biliary atresia in the derivation cohort (C statistic, 0.981; 95% confidence interval [CI]: 0.970, 0.992) and the validation cohort (C statistic, 0.995; 95% CI: 0.987, 1.000). The risk score also showed good calibration in both the derivation and the validation cohorts (P = .328 and P = .281, respectively). Conclusion A simple scoring system combining clinical and imaging features can help accurately estimate the risk for biliary atresia in patients with neonatal cholestasis.


Subject(s)
Biliary Atresia/complications , Biliary Atresia/diagnostic imaging , Cholestasis/complications , Cholestasis/diagnostic imaging , Bile Ducts/diagnostic imaging , Female , Humans , Infant , Male , Radionuclide Imaging/methods , Reproducibility of Results , Retrospective Studies , Risk , Risk Assessment , Ultrasonography/methods
18.
J Magn Reson Imaging ; 47(3): 767-778, 2018 03.
Article in English | MEDLINE | ID: mdl-28815859

ABSTRACT

PURPOSE: To evaluate in pediatric patients the diagnostic performance of magnetic resonance imaging (MRI) for suspected appendicitis and its negative appendectomy rate. MATERIALS AND METHODS: The study involved diagnostic accuracy studies that used MRI for pediatric patients with suspected appendicitis. Various field strengths and sequences were used in each included study. The diagnostic accuracy of MRI in pediatric patients with suspected appendicitis and negative appendectomy rate were assessed. A search of MEDLINE and EMBASE databases was performed until January 10, 2017. Two reviewers assessed the methodological quality of the articles using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Pooled sensitivity and specificity for appendicitis diagnosis were calculated using hierarchical logistic regression modeling. Meta-regression was performed to explore factors affecting study heterogeneity. The pooled negative appendectomy rate was analyzed. RESULTS: Thirteen original articles with 1946 patients were included. The summary sensitivity and specificity were 97% (95% confidence interval [CI], 95-98%) and 97% (95% CI, 93-98%), respectively; the area under the hierarchical summary receiver operating characteristic (HSROC) curve was 0.98 (95% CI, 0.97-0.99). In meta-regression, use of diffusion-weighted imaging (P < 0.01) and age (P < 0.01) affected heterogeneity, but there was no difference according to intravenous contrast agent use (P = 0.95). The pooled negative appendectomy rate of MRI was 4.5% (95% CI, 1.9-7.1%). CONCLUSION: MRI shows excellent diagnostic performance for appendicitis in pediatric patients regardless of the use of intravenous contrast media. Therefore, nonenhanced-only MRI protocols might be appropriate for pediatric patients with suspected appendicitis. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:767-778.


Subject(s)
Appendectomy/statistics & numerical data , Appendicitis/diagnostic imaging , Magnetic Resonance Imaging/methods , Adolescent , Appendicitis/surgery , Appendix/diagnostic imaging , Appendix/surgery , Child , Humans , Reproducibility of Results , Sensitivity and Specificity
19.
Eur Radiol ; 28(3): 1175-1186, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29018925

ABSTRACT

OBJECTIVE: To assess the diagnostic performance of shear-wave elastography for determining the severity of liver fibrosis in children and adolescents. METHODS: An electronic literature search of PubMed and EMBASE was conducted. Bivariate modelling and hierarchical summary receiver-operating-characteristic modelling were performed to evaluate the diagnostic performance of shear-wave elastography. Meta-regression and subgroup analyses according to the modality of shear-wave imaging and the degree of liver fibrosis were also performed. RESULTS: Twelve eligible studies with 550 patients were included. Shear-wave elastography showed a summary sensitivity of 81 % (95 % CI: 71-88) and a specificity of 91 % (95 % CI: 83-96) for the prediction of significant liver fibrosis. The number of measurements of shear-wave elastography performed was a significant factor influencing study heterogeneity. Subgroup analysis revealed shear-wave elastography to have an excellent diagnostic performance according to each degree of liver fibrosis. Supersonic shear imaging (SSI) had a higher sensitivity (p<.01) and specificity (p<.01) than acoustic radiation force impulse imaging (ARFI). CONCLUSIONS: Shear-wave elastography is an excellent modality for the evaluation of the severity of liver fibrosis in children and adolescents. Compared with ARFI, SSI showed better diagnostic performance for prediction of significant liver fibrosis. KEY POINTS: • Shear-wave elastography is beneficial for determining liver fibrosis severity in children. • Shear-wave elastography showed summary sensitivity of 81 %, specificity of 91 %. • SSI showed better diagnostic performance than ARFI for significant liver fibrosis.


Subject(s)
Elasticity Imaging Techniques/methods , Liver Cirrhosis/diagnosis , Liver/diagnostic imaging , Adolescent , Child , Humans , ROC Curve , Reproducibility of Results
20.
Eur Radiol ; 28(6): 2537-2548, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29327290

ABSTRACT

OBJECTIVE: To evaluate the diagnostic performance of reduced-dose CT for suspected appendicitis. METHODS: A systematic search of the MEDLINE and EMBASE databases was carried out through to 10 January 2017. Studies evaluating the diagnostic performance of reduced-dose CT for suspected appendicitis in paediatric and adult patients were selected. Pooled summary estimates of sensitivity and specificity were calculated using hierarchical logistic regression modelling. Meta-regression was performed. RESULTS: Fourteen original articles with a total of 3,262 patients were included. For all studies using reduced-dose CT, the summary sensitivity was 96 % (95 % CI 93-98) with a summary specificity of 94 % (95 % CI 92-95). For the 11 studies providing a head-to-head comparison between reduced-dose CT and standard-dose CT, reduced-dose CT demonstrated a comparable summary sensitivity of 96 % (95 % CI 91-98) and specificity of 94 % (95 % CI 93-96) without any significant differences (p=.41). In meta-regression, there were no significant factors affecting the heterogeneity. The median effective radiation dose of the reduced-dose CT was 1.8 mSv (1.46-4.16 mSv), which was a 78 % reduction in effective radiation dose compared to the standard-dose CT. CONCLUSION: Reduced-dose CT shows excellent diagnostic performance for suspected appendicitis. KEY POINTS: • Reduced-dose CT shows excellent diagnostic performance for evaluating suspected appendicitis. • Reduced-dose CT has a comparable diagnostic performance to standard-dose CT. • Median effective radiation dose of reduced-dose CT was 1.8 mSv (1.46-4.16). • Reduced-dose CT achieved a 78 % dose reduction compared to standard-dose CT.


Subject(s)
Appendicitis/diagnostic imaging , Tomography, X-Ray Computed/methods , Adult , Child , Humans , Logistic Models , Radiation Dosage , Sensitivity and Specificity , Tomography, X-Ray Computed/standards
SELECTION OF CITATIONS
SEARCH DETAIL