Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Cardiol Young ; 34(2): 272-281, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37337694

ABSTRACT

BACKGROUND: The use of peritoneal catheters for prophylactic dialysis or drainage to prevent fluid overload after neonatal cardiac surgery is common in some centres; however, the multi-centre variability and details of peritoneal catheter use are not well described. METHODS: Twenty-two-centre NEonatal and Pediatric Heart Renal Outcomes Network (NEPHRON) study to describe multi-centre peritoneal catheter use after STAT category 3-5 neonatal cardiac surgery using cardiopulmonary bypass. Patient characteristics and acute kidney injury/fluid outcomes for six post-operative days are described among three cohorts: peritoneal catheter with dialysis, peritoneal catheter with passive drainage, and no peritoneal catheter. RESULTS: Of 1490 neonates, 471 (32%) had an intraoperative peritoneal catheter placed; 177 (12%) received prophylactic dialysis and 294 (20%) received passive drainage. Sixteen (73%) centres used peritoneal catheter at some frequency, including six centres in >50% of neonates. Four centres utilised prophylactic peritoneal dialysis. Time to post-operative dialysis initiation was 3 hours [1, 5] with the duration of 56 hours [37, 90]; passive drainage cohort drained for 92 hours [64, 163]. Peritoneal catheter were more common among patients receiving pre-operative mechanical ventilation, single ventricle physiology, and higher complexity surgery. There was no association with adverse events. Serum creatinine and daily fluid balance were not clinically different on any post-operative day. Mortality was similar. CONCLUSIONS: In neonates undergoing complex cardiac surgery, peritoneal catheter use is not rare, with substantial variability among centres. Peritoneal catheters are used more commonly with higher surgical complexity. Adverse event rates, including mortality, are not different with peritoneal catheter use. Fluid overload and creatinine-based acute kidney injury rates are not different in peritoneal catheter cohorts.


Subject(s)
Acute Kidney Injury , Cardiac Surgical Procedures , Water-Electrolyte Imbalance , Infant, Newborn , Humans , Child , Cardiac Surgical Procedures/adverse effects , Water-Electrolyte Imbalance/etiology , Water-Electrolyte Imbalance/prevention & control , Water-Electrolyte Balance , Acute Kidney Injury/epidemiology , Acute Kidney Injury/etiology , Catheters, Indwelling/adverse effects , Retrospective Studies
2.
J Pediatr Intensive Care ; 7(3): 163-165, 2018 Sep.
Article in English | MEDLINE | ID: mdl-31073489

ABSTRACT

Post-cardiotomy mediastinitis is an especially serious complication after the implantation of prosthetic vascular grafts. Standard of care is irrigation, debridement, and removal of all prosthetic material present in the surgical field. The use of antibiotic impregnated beads at the site of infection has been reported in the salvage of vascular grafts in the adult population. We present the case of a 3-year-old child with hypoplastic left heart syndrome who developed mediastinitis following the Fontan operation. In a nontraditional approach, the Fontan conduit, which was surrounded by gross purulence, was successfully salvaged with the adjunctive use of vancomycin-impregnated beads.

SELECTION OF CITATIONS
SEARCH DETAIL