Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters

Database
Language
Journal subject
Affiliation country
Publication year range
1.
Dalton Trans ; 49(30): 10334-10338, 2020 Aug 04.
Article in English | MEDLINE | ID: mdl-32691808

ABSTRACT

Zinc(ii) and zirconium(iv) metal-organic frameworks show uptake and slow release of the ant alarm pheromones 3-octanone and 4-methyl-3-heptanone. Inclusion of N-propyl groups on the MOFs allows for enhanced uptake and release over several months. In preliminary field trials, leaf cutting ants show normal behavioural responses to the released pheromones.


Subject(s)
Ketones/chemistry , Metal-Organic Frameworks/chemistry , Molecular Structure , Zinc/chemistry , Zirconium/chemistry
2.
Biochim Biophys Acta ; 1689(2): 103-13, 2004 Jun 28.
Article in English | MEDLINE | ID: mdl-15196591

ABSTRACT

Poloxamer 188 is a complex polydisperse mixture of non-ionic macromolecules. Adverse non-IgE-mediated hypersensitivity reactions occur in some individuals following intravenous injection of poloxamer 188-based pharmaceuticals, presumably via complement activation. Here we have delineated potential causal chemical and biological interactive factors behind poloxamer 188-induced complement activation in human serum specimens. We identified the molecular constituents inherent in poloxamer 188 preparations and studied their effect on generation of the two complement split products, SC5b-9 and Bb. Poloxamer 188 activated complement at sub-micellar concentrations and the results indicated the potential involvement of all three known complement activation pathways. The poloxamer-induced rise of SC5b-9 in human sera was abolished in the presence of a recombinant truncated soluble form of complement receptor type 1, thus confirming the role of C3/C5 convertases in the activation process. Poloxamer 188-mediated complement activation is an intrinsic property of these macromolecules and was independent of the degree of sample polydispersity, as opposed to other non-polymeric constituents. Poloxamer 188 preparations also contained unsaturated chains of diblock copolymers capable of generating SC5b-9 in human sera; this effect was terminated following the removal of double bonds by catalytic hydrogenation. By quasi-elastic light scattering, we established interaction between poloxamer and lipoproteins; interestingly, poloxamer-induced rise in SC5b-9 was significantly suppressed when serum HDL and LDL cholesterol levels were increased above normal to mimic two relevant clinical situations. This observation was consistent with previously reported data from patients with abnormal or elevated lipid profiles where no or poor complement activation by poloxamer 188 occurred. Our findings could provide the basis of novel approaches to the prevention of poloxamer-mediated complement activation.


Subject(s)
Complement Activation/drug effects , Drug Hypersensitivity/blood , Drug Hypersensitivity/etiology , Lipoproteins/blood , Poloxamer/adverse effects , Drug Hypersensitivity/immunology , Humans , Reproducibility of Results , Sensitivity and Specificity
3.
Anal Biochem ; 361(2): 287-93, 2007 Feb 15.
Article in English | MEDLINE | ID: mdl-17196543

ABSTRACT

Block copolymers are increasingly being applied in areas such as transfection, membrane sealing, site-specific targeting, and bionanoengineering yet there is a relative paucity of assays available for simple, stable and reproducible colorimetric determination of copolymer concentration in solution. We have focused on improving the accuracy and reproducibility of a modified version of the Stewart biphasic colorimetric assay for quantitative determination of Pluronic (poloxamer) and Tetronic (poloxamine) macromolecules. The optimized assay achieved linear response ranges in chloroform for commonly used copolymers such as poloxamine 904 (20-300 microg/ml), poloxamine 908 (10-400 microg/ml), poloxamer 402 (20-400 microg/ml), and poloxamer 407 (10-400 microg/ml). Variation in the type of chlorinated solvent used significantly increased assay sensitivity, presumably through macromolecular reorientation, affording increased access for copolymer-ferrothiocyanate complexation. This was found to be optimally favored by the planar geometry of the solvent cis 1,2-dichloroethylene. For application to biological systems copolymer-protein interactions were for the first time determined and were found to be dependent on the fraction of hydrophobic constituents of the block copolymers and protein type. For instance serum albumin was found to interact with copolymers of low hydrophilic-lipophilic balance values and poly(propylene oxide) contaminants, whereas this interaction was not significant with the relatively hydrophilic IgG. In such systems the colorimetric assay directly determines the fraction of unbound (free) copolymer in the presence of proteins.


Subject(s)
Colorimetry/methods , Ethylenediamines/analysis , Poloxamer/analysis , Proteins/analysis , Colorimetry/standards , Dichloroethylenes/chemistry , Humans , Serum/chemistry , Solvents/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL